Cassette PLC Splitter

BWN-PLC-CT-1X32-LC-APC-2.0 1×32 LC/APC Cassette-Type PLC Splitter

A 1×32 cassette PLC splitter with LC/APC connectors on 2.0mm pigtails: the standard GPON 1:32 split at half the SC adapter footprint, for high-density ODFs, splitter panels and CO builds. 16.5/16.9dB insertion loss (P/S grade), 1260–1650nm, -40~+85°C.

1×32 LC/APC Cassette PLC Splitter Overview

The BWN-PLC-CT-1X32-LC-APC-2.0 is a 1×32 PLC splitter in a protected ABS cassette, terminated with LC/APC connectors on 2.0mm pigtails. Optically it is the same planar 1×32 family as the SC version — 16.5/16.9dB insertion loss (P/S grade), flat across 1260–1650nm. The reason to specify this model is not the optics; it is the footprint.

Thirty-two SC adapters consume roughly twice the panel space of thirty-two LC adapters. On a crowded ODF, a high-density splitter panel, or any build where rack units are budgeted, the LC interface is what makes a full 1:32 split fit. The cassette drops into the same distribution boxes, cabinets and panels; only the connector field changes. Family overview: cassette PLC splitter category.

Key Features

  • Full 1×32 split at LC density: 32 outputs on LC/APC, halving the adapter footprint versus SC on the same split ratio.
  • APC polish on LC: 8° angled end-faces keep return loss ≥55dB for PON-grade links.
  • Same optical family as the SC model: planar chip, 16.5/16.9dB IL (P/S), 1.5dB-class uniformity, 1260–1650nm.
  • Protected cassette format: ABS module for distribution boxes, cabinets and splitter panels.
  • Wide temperature rating: -40°C to +85°C operating and storage.
  • Configurable at order: 1m / 2.0mm pigtails standard; 0.9mm, 3.0mm and custom lengths available.

Specifications — 1×32 LC/APC Configuration

ParameterValue (this model)
ModelBWN-PLC-CT-1X32-LC-APC-2.0
Splitter TypePLC (planar lightwave circuit), cassette module
Configuration1 × 32
ConnectorsLC/APC, input and output
Fiber Diameter2.0mm pigtails (0.9mm / 3.0mm options)
Fiber Length1m standard, customized on request
Fiber TypeG657A (customer-specified fiber available)
Operating Wavelength1260–1650nm
Insertion Loss (P/S grade)16.5 / 16.9dB
Loss Uniformity≤ 1.5dB
Return Loss≥ 55dB (APC)
Polarization Dependent Loss≤ 0.3dB
Directivity≥ 55dB
Wavelength Dependent Loss≤ 0.5dB
Temperature Stability (-40~+85°C)≤ 0.5dB
Operating / Storage Temperature-40°C to +85°C
ComplianceTelcordia GR-1209-CORE, GR-1221-CORE (per BWNFiber product documentation)

1×N PLC Splitter Reference Table (Series Values)

Parameters1×21×41×81×161×321×64
Operating Wavelength (nm)1260~1650
Fiber TypeG657A or customer specified
Insertion Loss (dB) (P/S Grade)3.8/4.07.1/7.310.2/10.513.5/13.716.5/16.920.5/21.0
Loss Uniformity (dB)0.40.60.81.21.52.0
Return Loss (dB)555555555555
Polarization Dependent Loss (dB)0.20.20.20.250.30.35
Directivity (dB)555555555555
Wavelength Dependent Loss (dB)0.30.30.30.50.50.5
Temperature Stability (-40~85°C) (dB)0.40.40.40.50.50.5
Operating / Storage Temperature (°C)-40~+85

Values above are the published 1×N reference figures for the BWNFiber PLC series; this page is the 1×32 column. Confirm the cassette outline drawing against the current datasheet before ordering.

Note: split loss is set by the planar chip — connector form (LC/SC) does not change the 1×32 split loss; it changes the mated-connector loss budget and the panel footprint.

Connectors, Fiber Types & Compatibility

This model ships with LC/APC connectors throughout. LC/APC is less common than SC/APC in drop-side field craft — confirm your plant standard before specifying. Fiber is G657A bend-insensitive singlemode standard; customer-specified fiber available. Pigtails are 2.0mm jacketed at 1m standard, with 0.9mm for dense routing and 3.0mm for ruggedized legs.

The cassette mates with LC adapter fields on high-density ODF frames, splitter panels and distribution enclosures, and matches LC-equipped fiber termination boxes. The cassette is a protected component, not a sealed outdoor device.

Applications

  • High-density FTTH distribution: a full 1:32 GPON branch where the panel or ODF cannot host 32 SC adapters.
  • Central office / headend splits: CO-side splitting where LC is the house standard.
  • Space-constrained cabinets: street cabinets where splitter count per enclosure is being maximized.
  • PON today, XGS-PON tomorrow: the 1260–1650nm window keeps the passive layer valid through active upgrades.

How to Choose the Right Configuration

1. Connector form first: LC for density-constrained panels and CO builds; SC for field-standard FTTH distribution — see the SC/APC 1×32 sibling.

2. Polish: APC for PON; UPC only for non-PON enterprise links.

3. Split ratio: 1×32 covers a full GPON branch; 1×16/1×8 for smaller branches or cascaded designs.

4. Package: this cassette for enclosures with adapter fields; steel-tube or bare formats for splice-in builds; LGX cards for rack chassis.

5. Pigtails: match jacket diameter and length to the enclosure routing space.

How This Model Differs from Its Neighbors

ModelConnectorsAdapter footprintBest for
This page: 1×32 cassette LC/APCLC/APCHalf of SCDense panels, CO builds
1×32 cassette SC/APCSC/APCStandardStandard GPON field
1×32 cassette SC/UPC 3.0SC/UPCStandardNon-PON enterprise
1×64 cassette SC→LCSC/APC in → LC/APC outHybrid (dense output side)Max split + dense outputs

Family navigation: cassette PLC splitters · all PLC formats · splitter loss chart.

Testing & Quality Control

The published characterization for this series covers per-port insertion loss, port-to-port uniformity, return loss and polarization dependent loss across 1260–1650nm, stated to Telcordia GR-1209-CORE / GR-1221-CORE generic requirements. For project orders, share your acceptance criteria (per-port IL, uniformity window, RL floor) and we align shipment documentation accordingly.

Packaging & Ordering Information

  • Model: BWN-PLC-CT-1X32-LC-APC-2.0 (PLC · cassette module · 1×32 · LC/APC · 2.0mm)
  • Standard supply: 1×32 split, LC/APC connectors, 2.0mm G657A pigtails, 1m length
  • Options on request: 0.9mm and 3.0mm pigtail jackets, custom lengths, customer-specified fiber
  • Packaging, MOQ and lead time are confirmed per order — send your quantity and destination for a written confirmation

Request a Quote for the 1×32 LC/APC Cassette PLC Splitter

Send these six parameters for a configured quote:

  1. Split configuration (this page: 1×32)
  2. Package (cassette module)
  3. Connector and polish (standard: LC/APC)
  4. Pigtail diameter (0.9 / 2.0 / 3.0mm) and length (standard 1m)
  5. Fiber type (standard G657A, or customer specified)
  6. Quantity and installation environment (ODF, panel, cabinet)

Contact the BWNFiber team or use the inquiry form on this page for pricing, datasheets, and samples.

FAQ

BWN-PLC-CT-1X32-LC-APC-2.0 1×32 LC/APC Cassette-Type PLC Splitter FAQ

What is a 1×32 LC/APC cassette PLC splitter?

A planar lightwave circuit splitter that divides one optical input into 32 outputs, packaged in a protected ABS cassette and terminated with LC/APC connectors. It delivers the standard GPON 1:32 split at roughly half the adapter footprint of SC.

Why choose LC instead of SC on a 1×32 splitter?

Density. LC adapters occupy roughly half the panel space of SC adapters, so 32 LC ports fit panels and ODF positions that cannot host 32 SC ports. If panel space is not constrained, the SC/APC version is the more common field choice.

Does the LC version have the same optical performance as SC?

The split loss is set by the planar chip — 16.5/16.9dB (P/S grade) at 1×32 for this series either way. Connector form affects the mated-pair loss budget and the panel footprint, not the split ratio.

Is LC/APC common in PON networks?

SC/APC is the dominant field connector for FTTH drops; LC/APC appears where density rules — central offices, high-density ODFs, splitter panels — and in some data-hall builds. Confirm the plant standard on both ends before specifying LC.

What is the insertion loss at 1×32?

Published series figure: 16.5/16.9dB (P/S grade) with 1.5dB-class uniformity. Budget mated connectors and splices separately, and confirm against the current datasheet when ordering.

Can this cassette be installed outdoors?

Only inside a sealed distribution box, cabinet or closure — the cassette is a protected component, not an outdoor enclosure. The module itself is rated -40°C to +85°C.

What pigtail options are available?

2.0mm jacketed pigtails at 1m are standard for this model; 0.9mm for dense internal routing and 3.0mm for ruggedized legs, plus custom lengths — state your requirement in the RFQ.

Do you support OEM and project volumes?

Yes. Send split ratio, connector confirmation (LC/APC), pigtail spec, quantity and destination; we confirm the build on a datasheet and quote project pricing.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.