BWNFiber 100G QSFP28 to 4x SFP28 Passive DAC Cable

Start with reach and endpoint mapping, not the headline data rate. The BWNFiber 100G QSFP28 to 4x SFP28 DAC, also specified as a QSFP28 breakout DAC, is built for a QSFP28 uplink to 4x SFP28 fan-out link for port consolidation, staged speed migration, and high-density server or accelerator attachment. It keeps the link passive and avoids an optical conversion stage. Standard and custom ordering options should be confirmed against the host port, requested length, and environmental requirements before the BOM is approved.

100G — Aggregate link QSFP28 to 4x SFP28 — Endpoint mapping Up to 5 m listed — Datasheet guidance
Verified Specifications

100G QSFP28 to 4x SFP28 Passive DAC Cable Specifications

Link roleA QSFP28 uplink to 4x SFP28 fan-out link for port consolidation, staged speed migration, and high-density server or accelerator attachment.
Endpoint form factorQSFP28 to 4x SFP28; lane breakout must be enabled on the host port
Aggregate data rate100G
Lane / channel detail100G aggregate split across the endpoint legs shown in the product name
Length guidanceUp to 5 m listed
Power approachPassive cable assembly; no active optical engine
Standards / managementCompliant with IEEE 802.3bj and InfiniBand EDR; Meets SFF-8636 / SFF-8402
Cable construction30 AWG to 26 AWG cable available; copper twinax assembly
Operating temperature0°C to 70°C (commercial)
Configuration statusStandard and custom options must be confirmed in the quotation and approved BOM

Search terminology for this configuration includes 100G to 25G DAC, fanout DAC 100G, 100G breakout copper, QSFP28 to SFP28 DAC cable. These phrases describe the same purchase task only when the endpoint form factor, breakout ratio and lane map, and ordered length match this page.

Standards context: IEEE 802 standards catalog · SNIA SFF technology affiliates.

Selection

When to Use This 100G Passive DAC

  • Use it for fan-out links with QSFP28 to 4x SFP28 endpoints when the routed path stays within up to 5 m listed.
  • Choose passive copper when low cable power and simple installation matter more than reach or cable diameter.
  • Confirm that the source port supports the required breakout mode and that each leg maps to the intended downstream port.
Choose an alternative when: Use an ACC when a copper route exceeds the practical passive budget but remains short. Use an AOC when the route needs more distance, a lighter cable body, or EMI immunity.
Deployment Control

Compatibility and Acceptance Checklist

  1. Confirm the connector at each end: QSFP28 to 4x SFP28.
  2. Confirm the required aggregate rate and host lane mode: 100G aggregate split across the endpoint legs shown in the product name.
  3. Measure the routed path, not the straight-line rack distance; the current datasheet states up to 5 m listed.
  4. Send switch/NIC part numbers and firmware versions for coding review; no platform-specific compatibility is assumed without validation.
  5. Provide the lane-to-leg map, leg labels, and branch length before production approval.
  6. Enable and validate host breakout mode before acceptance testing each downstream leg independently.
  7. Specify commercial or industrial temperature requirements and the requested jacket/label/packaging details.
  8. At receipt, verify labels and part numbers, inspect latches and cable jackets, then test the complete link at the intended data rate.

1 Differential Insertion Loss (SDD21 Max.)

AWG / Length1.25 GHz2.5 GHz5.0 GHz7.0 GHz10 GHz12.89 GHz
30 AWG (1 m) Max4.5 dB5.4 dB6.3 dB7.5 dB8.5 dB10.5 dB
30/28 AWG (3 m) Max7.5 dB9.5 dB12.2 dB14.8 dB18.0 dB21.5 dB
26 AWG (3 m) Max5.7 dB7.2 dB9.9 dB11.9 dB14.1 dB16.5 dB
26/25 AWG (5 m) Max7.8 dB10.0 dB13.5 dB16.0 dB19.0 dB22.0 dB
BOM Planning

Ordering Options

Part NumberDescriptionLengthWire Gauge
BWN-DAC-QSFP28-4SFP28-100G-01M100G QSFP28 to 4xSFP28 Passive DAC1 m30 AWG
BWN-DAC-QSFP28-4SFP28-100G-03M100G QSFP28 to 4xSFP28 Passive DAC3 m30/28 or 26 AWG
BWN-DAC-QSFP28-4SFP28-100G-05M100G QSFP28 to 4xSFP28 Passive DAC5 m26/25 AWG
BWN-DAC-QSFP28-4SFP28-100G-xxM100G QSFP28 to 4xSFP28 Passive DACCustomCustom
Buyer Questions

Common Procurement Objections

Will it work in my switch or NIC?

Form factor and standards alignment are necessary but not sufficient. Send the exact host model, firmware, port mode, length, and coding requirement for a compatibility review.

Which length should I order?

The current datasheet lists up to 5 m listed. Measure the routed path, include a controlled service loop, and avoid ordering unnecessary slack.

Should I use AOC instead?

Use an ACC when a copper route exceeds the practical passive budget but remains short. Use an AOC when the route needs more distance, a lighter cable body, or EMI immunity.

Can BWNFiber customize the assembly?

Datasheet ordering tables include standard and/or custom entries. Submit the endpoint, length, label, jacket, coding, temperature, packaging, and quantity requirements for feasibility confirmation.

Related Choices

Related High-Speed Cable Options

Engineering RFQ

Request a Configuration Review

Send endpoint models, firmware, port mode, length, quantity, temperature, labeling, packaging, and acceptance requirements. BWNFiber can return a proposed cable code and BOM for review.

Send Your Requirements

FAQ

100G QSFP28 to 4x SFP28 Passive DAC Cable FAQ

What is the BWNFiber 100G QSFP28 to 4x SFP28 Passive DAC Cable?

BWNFiber 100G QSFP28 to 4x25G SFP28 Passive Direct Attach Copper Cable is based on a 4x25G structure, meeting the needs of next-generation 100G switches, servers, routers and other product applications. The QSFP28 cable assembly uses an optimized design to reduce crosstalk and insertion loss, delivering excellent signal integrity and fully complying with next-generation 100G Ethernet and InfiniBand EDR standards. This breakout cable supports interconnection between the two interface types with a single-channel transmission rate of 25 Gbps. The page uses the supplied datasheet as the claim source; final host compatibility remains configuration-specific.

What link length is available for this DAC?

The current datasheet indicates up to 5 m listed. The usable length for a particular deployment still depends on the ordered part number, host electrical budget, route, and acceptance criteria.

Which interfaces does this cable connect?

This product is defined as QSFP28 to 4x SFP28. Match the complete connector, lane mode, and endpoint role rather than relying on aggregate speed alone.

Does the host need breakout mode enabled?

Yes. The source port must support the specified fan-out mode, and each leg must be mapped and tested at its downstream rate.

How do I check QSFP28 to 4x SFP28 compatibility?

Provide the two host model numbers, firmware versions, port type, port mode, required cable code, and planned length. A standards match does not by itself prove a host will accept every third-party cable code.

When should I choose DAC for this link?

Use it for fan-out links with QSFP28 to 4x SFP28 endpoints when the routed path stays within up to 5 m listed. Choose passive copper when low cable power and simple installation matter more than reach or cable diameter. Confirm that the source port supports the required breakout mode and that each leg maps to the intended downstream port.

What should be included in an RFQ?

Include endpoint A and B, host models, firmware, port mode, length and service-loop allowance, quantity, temperature, jacket, label, packaging, destination, and required acceptance tests.

How should the cable be accepted on arrival?

Verify the label and ordered part number, inspect the cable and latches, connect to the intended hosts, confirm link state and lane mode, then run the site-defined traffic or BER acceptance procedure.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.