BWNF-GE-CXXL-40D
1.25G CWDM SFP 40 km Duplex LC Transceiver
BWNF-GE-CXXL-40D is the working model for a 1.25 Gb/s CWDM SFP intended for duplex single-mode fiber links with a nominal reach class of 40 km. The order must identify one exact CWDM wavelength, the host device, temperature grade, required coding and quantity. The 40 km label is a product reach class, not a guarantee that an unverified route will operate over 40 km.

Product Value Summary
BWNF-GE-CXXL-40D is the working model for a 1.25 Gb/s CWDM SFP intended for duplex single-mode fiber links with a nominal reach class of 40 km. The order must identify one exact CWDM wavelength, the host device, temperature grade, required coding and quantity. The 40 km label is a product reach class, not a guarantee that an unverified route will operate over 40 km.
Evidence boundary: the supplied folder does not contain an approved BWNFiber datasheet, optical test report, compatibility matrix or labeled product photograph. The identity and specifications below therefore remain provisional until BWNFiber approves the source record.
Short Answer for Buyers
Use this SKU only when the project requires a 1.25G SFP on a CWDM channel and the complete optical path passes a link-budget review. Before requesting a quote, provide the transmit wavelength, switch or router model, mux/demux channel plan, route loss, connector loss, splice loss, engineering margin, temperature grade and quantity. BWNFiber should confirm the exact part code and optical limits in a signed-off datasheet before an order is released.
Key Features
- Working configuration: 1.25 Gb/s SFP, CWDM, duplex LC, single-mode fiber, 40 km reach class.
- Exact wavelength must be selected from the approved product channel list. TBC — source required.
- Digital optical monitoring (DOM/DDM). TBC — source required.
- CWDM DFB transmitter and PIN receiver. TBC — source required.
- Host EEPROM coding may be available after the exact platform is reviewed. TBC — source required.
- Commercial and industrial temperature options may be available. TBC — source required.
Technical Specifications
| Parameter | Provisional value | Publication status |
|---|---|---|
| Model | BWNF-GE-CXXL-40D | Working identifier from supplied file |
| Form factor | SFP | TBC — source required |
| Nominal data rate | 1.25 Gb/s | TBC — source required |
| WDM family | CWDM | Working identifier; approve against datasheet |
| Nominal wavelength | One ordered CWDM channel; proposed range 1270–1610 nm | TBC — source required |
| Nominal channel spacing | 20 nm under ITU-T G.694.2 | Industry grid reference; SKU coverage TBC |
| Reach class | Up to 40 km on single-mode fiber | TBC — source required; link budget governs route acceptance |
| Optical connector | Duplex LC | TBC — source required |
| Transmitter | CWDM DFB | TBC — source required |
| Receiver | PIN / PIN-TIA | TBC — source required |
| DOM/DDM | Proposed: supported | TBC — source required |
| Supply voltage | Proposed: 3.3 V nominal | TBC — source required |
| Maximum power | Proposed: ≤1.0 W | TBC — source required |
| Commercial case temperature | Proposed: 0 to +70 °C | TBC — source required |
| Industrial case temperature | Proposed option: −40 to +85 °C | TBC — source required |
| Minimum transmit power | Proposed: −5 dBm | TBC — source required |
| Maximum transmit power | Proposed: 0 dBm | TBC — source required |
| Receiver sensitivity | Proposed: −24 dBm maximum | TBC — source required |
| Receiver overload | Proposed: −3 dBm | TBC — source required |
| Standards/agreements | Proposed: SFP MSA / INF-8074i and SFF-8472 | Compliance declaration TBC |
| RoHS | Proposed | TBC — source required |
Interface and Fiber Conditions
The proposed interface is duplex LC over single-mode fiber. Confirm connector polish, patch-cord type, fiber specification and end-to-end loss before ordering. Do not infer LC/UPC, OS2, a specific fiber standard or a supported patch cord from the connector name alone; those details require the approved product datasheet and route design.
How to Verify the 40 km Link
“40 km” is a nominal reach class. Route acceptance requires an optical link budget:
available budget = minimum transmitter output − receiver sensitivity
Compare the available budget with the sum of fiber attenuation, CWDM mux/demux loss, connector loss, splice loss, patch-panel loss and an agreed engineering margin. Use the approved BWNFiber optical limits and the actual route design; do not calculate acceptance from the provisional values in this draft.
Required Link-Budget Inputs
- Exact wavelength at each end.
- Fiber type and measured route length.
- Fiber attenuation at the selected wavelength.
- Mux/demux model and insertion loss.
- Number and loss allowance of connectors, adapters and splices.
- Required engineering margin.
- Minimum transmitter output and receiver sensitivity from the approved datasheet.
- Receiver overload check for short or low-loss routes.
Compatibility and Application Conditions
SFP form-factor or MSA language does not prove compatibility with a particular switch, router, NIC or line card. Send the exact manufacturer, host model, hardware revision and operating-system version. BWNFiber should confirm the EEPROM code and, where required, validate a sample in the named host before the bulk order.
Potential applications, subject to engineering confirmation, include Gigabit Ethernet CWDM access links, campus or metro CWDM paths and compatible mux/demux systems. SAN, Fibre Channel and other protocol claims are TBC — source required and must not be published from this draft alone.
How to Select the Correct Configuration
| Decision | What the buyer must confirm | Why it matters |
|---|---|---|
| Data rate and host port | Exact device and port specification | A physical SFP fit does not establish electrical or protocol compatibility |
| CWDM wavelength | Exact nominal wavelength in nm and mux port | A range such as 1270–1610 nm is not one orderable channel |
| Reach class | Route loss and margin, not distance alone | Passive losses can consume the budget before 40 km |
| Connector path | Duplex LC interface and patching details | Avoids connector/polish and patching mismatch |
| Temperature grade | Commercial or industrial environment | The ordered grade must match field conditions |
| EEPROM code | Host brand and exact model | Generic and host-coded modules may be identified differently |
| Quantity and validation | Sample need, batch quantity and acceptance plan | Reduces bulk-order compatibility risk |
Difference From Related Reach Variants
| Variant | Intended selection role | Required evidence before publication |
|---|---|---|
| 20 km CWDM SFP | Lower-loss/shorter CWDM route | Approved 20 km optical limits and SKU mapping |
| 40 km CWDM SFP — this page | Route requiring the 40 km reach class | Approved 40 km optical limits, channel list and link-budget boundary |
| 80 km CWDM SFP | Higher-budget CWDM route | Approved 80 km optical limits and receiver type |
| 120 km CWDM SFP | Long-reach CWDM route | Approved 120 km channel range, optics and engineering constraints |
Do not select a longer reach solely as “extra safety.” Excess receive power, different optics, cost and route design may change. Validate both the minimum-loss and maximum-loss cases.
Testing and Quality-Control Requirements
The following is the minimum evidence package recommended for this SKU; it is not a claim that BWNFiber currently performs or supplies every item:
- Approved datasheet tied to BWNF-GE-CXXL-40D and revision date.
- Serial-number or batch traceability method. TBC.
- Optical transmit power, receive sensitivity and wavelength test method. TBC.
- DOM/DDM reading verification. TBC.
- Host recognition or traffic test for the requested coding. TBC.
- Commercial/industrial temperature validation when ordered. TBC.
- RoHS or other compliance documentation only when a valid document applies to this exact product. TBC.
Packaging and Procurement Information
Packaging format, label content, MOQ, sample policy, lead time, warranty, country of origin and export documentation are TBC — source required. Request these items in the quotation rather than assuming them from another optical-transceiver SKU.
Information Required for an RFQ
Send:
- Product model: BWNF-GE-CXXL-40D.
- Exact CWDM wavelength in nm.
- Host manufacturer and exact device/line-card model.
- Required EEPROM code or generic MSA request.
- Route length and complete optical loss budget.
- CWDM mux/demux model and channel plan.
- Commercial or industrial temperature grade.
- Required documentation and acceptance tests.
- Sample quantity, production quantity and destination country.
Primary CTA: Request the approved BWNF-GE-CXXL-40D datasheet and a configuration review.
Secondary CTA: Send the host model, CWDM wavelength, route loss and quantity for a quotation.
Downloads
- Product datasheet: TBC — source required
- Mechanical drawing: TBC — source required
- Optical test report/sample report: TBC — source required
- Compatibility confirmation: issued only for the named host and approved coding TBC
Frequently Asked Questions
Is 1270–1610 nm one tunable module?
Not unless an approved BWNFiber datasheet explicitly says so. For this fixed-channel working SKU, treat 1270–1610 nm as a family range and specify one nominal CWDM wavelength on the RFQ.
Does 40 km mean the module will work on every 40 km route?
No. The complete loss budget, mux/demux loss, connector and splice loss, engineering margin, transmitter output, receiver sensitivity and receiver overload must be checked.
Which wavelength should I order?
Use the wavelength assigned to the matching CWDM mux/demux port and confirm that it is offered for BWNF-GE-CXXL-40D. State the wavelength in nm; the approved channel list is TBC — source required.
Can I order a DWDM channel with this model?
No DWDM option is established by the current evidence. This draft positions BWNF-GE-CXXL-40D as a CWDM SKU. Use a separately verified DWDM model for a DWDM grid.
Is DOM/DDM supported?
The supplied working draft says yes, but an approved datasheet or sample test is required before publication or purchase.
Is the module compatible with Cisco, Juniper, Arista or another brand?
Compatibility is host-specific. Provide the exact device and port model. Do not rely on a generic brand list; request written confirmation or sample validation for the required coding.
Is an industrial-temperature version available?
The working draft proposes −40 to +85 °C as an option, but the orderable suffix, electrical limits and qualification evidence are TBC — source required.
What fiber patch cord should be used?
The working interface is duplex LC single-mode. Connector polish, fiber specification and patch-cord construction must match the approved datasheet and the installed path.
Can I replace a 20 km optic with this 40 km model?
Not automatically. Check host coding, wavelength, receive overload, link loss and mux/demux compatibility before changing reach class.
What should I request before a bulk order?
Request the approved datasheet, exact part-code mapping, compatibility confirmation, sample-test plan, acceptance criteria, labeling requirements, warranty terms and lead time.
Related Products