BWN-APC-M12-OM3-AQ-{POL}-{JKT}-{LEN} + configuration options
MPO 12 Fiber OM3 Armored Patch Cord
The BWNFiber armored 12-fiber MPO OM3 patch cord wraps an aqua OM3 assembly in spiral steel armor and terminates one MPO-12 PC female connector on each end. It protects exposed indoor runs, trays and rodent-risk paths without changing the optical grade.

Product Overview
The BWNFiber armored 12-fiber MPO OM3 patch cord wraps an aqua OM3 assembly in spiral steel armor and terminates one MPO-12 PC female connector on each end. It protects exposed indoor runs, trays and rodent-risk paths without changing the optical grade.
The armor is mechanical protection only — the link still performs to OM3. This page is the aqua armored build in 1-50 m lengths; for tight spaces that specify a 5.0 mm micro-armored black jacket, use the T9 build instead, and for protected in-cabinet patching the unarmored T7 cord is enough. Type A, Type B or Type C polarity is built to the site drawing.
Key Features
- One MPO-12/PC female connector on each end
- 12 live fibers, OM3 50/125 μm multimode
- Spiral steel armor against crush and rodent damage
- Aqua outer jacket keeps OM3 identification on trays
- 1-50 m length set for exposed routes
- Type A, Type B or Type C polarity built to the site drawing
- 100% factory-terminated and optically tested before shipment
Technical Specifications
| Item | Specification |
|---|---|
| Product family | Armored MPO Patch Cord |
| Interface | MPO-12 to MPO-12 |
| Active fibers | 12 |
| Fiber type | OM3 multimode, 50/125 μm |
| Jacket color | Aqua |
| Polish | PC |
| Gender | Female (F), both ends |
| Polarity | Type A / Type B / Type C, per order |
| Construction | Spiral armored |
| Overall length | 1-50 m standard set; custom on request |
| Standards | TIA/EIA-568.3-D, EIA/TIA 604-5, IEC 61754-7, IEC 61753-1, GR-1435-CORE, RoHS |
Final insertion loss and return loss limits follow the BWNFiber test specification for the selected loss grade. Test method reference: IEC 61300-3-4.
Selection Guidance
- Polarity is not field-switchable. Choose Type A, Type B or Type C from the site drawing before ordering.
- Female (unpinned) ends mate with pinned cassette, panel and transceiver ports; male (pinned) builds are quoted on request.
- Armor adds crush and rodent protection but also weight and bend radius — for protected in-cabinet patching, the unarmored cord routes easier.
- Need a slimmer protected build? The 5.0 mm black micro-armored version fits tighter pathways.
- Armor does not change the fiber grade: this page is OM3 aqua throughout.
Applications
- Exposed indoor runs, open trays and rodent-risk paths
- OM3 routes that cross mechanical workspaces or raised floors
- Temporary or re-deployable links that see handling wear
- Industrial-adjacent data rooms needing mechanical protection
Order Guide
This SKU is built to the ordered polarity and is not polarity-switchable in the field. Select the polarity from the site drawing, then overall length and jacket.
| Configuration | Part Number | Description |
|---|---|---|
| Type A | BWN-APC-M12-OM3-AQ-A-{JKT}-{LEN} | Armored MPO-12/PC (F) to MPO-12/PC (F) patch cord, 12F OM3, aqua |
| Type B | BWN-APC-M12-OM3-AQ-B-{JKT}-{LEN} | Armored MPO-12/PC (F) to MPO-12/PC (F) patch cord, 12F OM3, aqua |
| Type C | BWN-APC-M12-OM3-AQ-C-{JKT}-{LEN} | Armored MPO-12/PC (F) to MPO-12/PC (F) patch cord, 12F OM3, aqua |
Standard lengths: 1, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m. Custom lengths are quoted on the drawing.
Why Source from BWNFiber
BWNFiber factory-terminates and inspects every MPO end before shipment, records polarity per order, and can attach IL/RL test reports for project handover. Catalog jackets cover LSZH, OFNP and OFNR; PVC, TPU and PE are quoted on project orders, together with OEM printing and labeling. Armored assemblies are terminated and tested after armoring, so the protection never compromises the factory optical result. Send the interface, fiber type, polarity, jacket and length, and BWNFiber returns a build sheet before production.
View the complete MPO Trunk Cable series for related patch cord, armored, breakout and conversion configurations.
Need a Configuration Review or Sample?
Share the fiber count, connector map, polarity, jacket, overall length and quantity for a project-specific review.
Frequently Asked Questions
Does the armor change the fiber grade?
No. The armor is mechanical protection only. The assembly remains OM3 multimode throughout.
How is this different from the 5.0 mm black armored version?
This page is the aqua spiral-armored build. The 5.0 mm version uses a slimmer micro-armored black jacket on OM3-300 fiber for tighter pathways.
Is a black armored jacket singlemode?
Not necessarily — jacket color alone does not identify the fiber. This aqua build is OM3; always check the stated fiber type, not the color.
Which polarity should I order?
Polarity follows your channel plan. Type A, Type B and Type C are all built to order; confirm the cassette or panel method on the site drawing.
What lengths are listed?
1 m to 50 m in the standard set, plus custom lengths quoted on the drawing.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.