MPO Patch Cord

MPO 12 Fiber OS2 Low Loss Patch Cord

A 12-fiber OS2 low-loss MPO jumper for tighter single-mode link budgets, built to a fixed polarity.

12 Fibers | OS2 Singlemode | APC | Female (F) | Yellow | Low Loss | 3.0 mm | 0.5–15 m

Product Overview

This 12-fiber OS2 low-loss MPO patch cord links cassettes, adapter panels and equipment ports inside high-density racks. Both ends use generic MPO APC female connectors on a yellow 3.0 mm jacket. The low-loss grade is published only against the BWNFiber test limit. Polarity is built as Type A, B or C at the factory.

Key Features

  • Generic MPO connectors on both ends, not US Conec MTP and not SENKO MPO
  • 12 fibers, OS2 9/125 μm single-mode, yellow jacket
  • Low-loss grade locked to the published single-mode IL limit
  • Factory-set polarity Method A, B or C; not field-switchable
  • Factory terminated and inspected before shipment
  • Standard lengths from 0.5 m (2 ft) to 15 m (49 ft)
  • Jacket options: OFNP, OFNR and LSZH
  • OEM labeling, serial numbers and test records available

Applications

Use this 12-fiber OS2 low-loss assembly for single-mode cassette and panel patching where the optical budget is tight. It is still a 12-fiber build, not an 8-fiber DR4 cord.

Typical uses:

  • In-cabinet OS2 patching in MDA, HDA and EDA zones
  • Cassette-to-cassette and adapter-panel single-mode interconnect
  • 12-fiber structured single-mode channels through cassettes
  • High-density OS2 interconnect between adjacent racks
  • Loss-sensitive single-mode cassette channels

Technical Specifications

ParameterValue
Connector systemGeneric MPO
InterfaceMPO-12 to MPO-12
Active fibers12
Fiber typeOS2 single-mode, 9/125 μm
Jacket colorYellow
PolishAPC
Default genderFemale (F), unpinned, both ends
FeatureLow loss; polarity fixed at manufacture
Cable OD3.0 mm round, typical
Jacket ratingOFNP / OFNR / LSZH
PolarityType A / Type B / Type C, selected at order
Insertion loss, single-mode low loss≤0.35 dB, typical ≤0.25 dB
Insertion loss, single-mode standard≤0.75 dB, typical ≤0.40 dB
Return loss, single-mode APC≥60 dB
Wavelength1310 / 1550 nm
Durability≤0.2 dB change after 50 matings
Operating temperature−20 °C to +70 °C
Storage temperature−40 °C to +85 °C
Standard length set0.5 / 1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 m
StandardsTIA/EIA-568.3-D, EIA/TIA 604-5, IEC 61754-7, IEC 61753-1, GR-1435-CORE, RoHS

Final IL / RL limits follow the BWNFiber test specification for the selected loss grade.

Order Guide

This is a low-loss generic MPO patch cord. Polarity is selected at order and is not field-switchable. Choose Type A, B or C, jacket material and length.

Product descriptionPolarityLengthJacket material
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A0.5m (2ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A1m (3ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A1.5m (5ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A2m (7ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A3m (10ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A5m (16ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A7m (23ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A10m (33ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A15m (49ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A0.5m (2ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A1m (3ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A1.5m (5ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A2m (7ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A3m (10ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A5m (16ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A7m (23ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A10m (33ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A15m (49ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A0.5m (2ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A1m (3ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A1.5m (5ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A2m (7ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A3m (10ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A5m (16ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A7m (23ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A10m (33ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType A15m (49ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B0.5m (2ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B1m (3ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B1.5m (5ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B2m (7ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B3m (10ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B5m (16ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B7m (23ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B10m (33ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B15m (49ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B0.5m (2ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B1m (3ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B1.5m (5ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B2m (7ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B3m (10ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B5m (16ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B7m (23ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B10m (33ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B15m (49ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B0.5m (2ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B1m (3ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B1.5m (5ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B2m (7ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B3m (10ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B5m (16ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B7m (23ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B10m (33ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType B15m (49ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C0.5m (2ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C1m (3ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C1.5m (5ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C2m (7ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C3m (10ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C5m (16ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C7m (23ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C10m (33ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C15m (49ft)LSZH
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C0.5m (2ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C1m (3ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C1.5m (5ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C2m (7ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C3m (10ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C5m (16ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C7m (23ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C10m (33ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C15m (49ft)OFNP
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C0.5m (2ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C1m (3ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C1.5m (5ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C2m (7ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C3m (10ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C5m (16ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C7m (23ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C10m (33ft)OFNR
MPO-12/APC (F) to MPO-12/APC (F) Patch Cord, 12 Fibers, OS2 Singlemode Yellow, Low LossType C15m (49ft)OFNR

Custom length is available on request. Lengths above 15 m are quoted as extended assemblies.

Why Source MPO/MTP Patch Cord from BWNFiber?

  • Factory pre-terminated and 100% inspected before shipment
  • Connector brand in the title matches the hardware in the BOM
  • Project configuration by jacket, length, labeling and packaging
  • Build-sheet review before production on OEM and project orders
  • Serialized IL / RL and polarity records available with the shipment
  • One factory path for catalog SKUs and private-label assemblies

Need a Configuration Review or Sample?

Share the connector family, fiber count, polarity, jacket, length and quantity for a project-specific review.

Request a Sample and Quote

FAQ

Frequently Asked Questions

Which options do I select on this page?

Select polarity Type A, B or C, jacket LSZH / OFNP / OFNR, and length from 0.5 m (2 ft) to 15 m (49 ft). Connector family, fiber count, fiber type, polish and gender stay fixed on this page.

How is this different from a US Conec MTP or SENKO MPO jumper?

This page uses generic MPO connectors. Use MTP, MTP PRO or SENKO names only on pages that install those brands.

What is included when I source this jumper from BWNFiber?

Each assembly is factory terminated and inspected. Project orders can include polarity notes, custom length, cable print, labeled packaging and IL / RL records.

Can I change polarity or pin gender after installation?

No. This is a standard generic MPO assembly. Polarity and gender are fixed when the cord is built. Order the correct Type A, B or C method before production.

What is the difference between this low-loss jumper and the standard OS2 12-fiber page?

This page is the low-loss grade of the same 12-fiber OS2 APC build. Use it when the link budget needs the published low-loss IL limit. If the link uses 8 live fibers for DR4, order the 8-fiber OS2 page instead.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.