MPO-8 to 2x MPO-4 OS2 Conversion Cable
Eight OS2 fibers from one MPO-8 APC female into two MPO-4 APC female ports.

Product Overview
This 8-fiber OS2 conversion cable remaps one MPO-8 APC female port into two MPO-4 APC female ports on a yellow single-mode jacket. The 8 live fibers on the MPO-8 end are split into two groups of four and terminated on the two MPO-4 legs, so one 8-fiber single-mode MPO position feeds two 4-fiber MPO ports. As a single-mode MPO conversion cable, it keeps the link inside the MPO connector system end to end — no LC fan-out, no media change. Polarity is built as Type A, B or C at the factory and is not field-switchable. Overall length runs from 1 m to 50 m, with custom lengths quoted on the drawing.
Key Features
- MPO-8/APC female to 2 × MPO-4 APC female
- 8 live fibers, OS2 9/125 μm single-mode, yellow jacket
- APC polish on all three ends — mate with APC ports only
- Female (unpinned) default on all ends
- Factory-set polarity Type A, B or C; not field-switchable
- Overall length 1–50 m catalog set; custom lengths on the drawing
- Jacket options: LSZH, OFNP and OFNR
- Factory terminated and inspected before shipment
Technical Specifications
| Item | Specification |
|---|---|
| Product family | MPO Conversion Cable |
| Conversion map | MPO-8 → 2 × MPO-4 |
| Active fibers | 8 |
| Connector system | MPO (IEC 61754-7) |
| Fiber type | OS2 single-mode, 9/125 μm |
| Jacket color | Yellow |
| Polish | APC on all ends |
| Gender | Female (F), unpinned, all ends |
| Polarity | Type A / Type B / Type C, factory-set at order |
| Overall length | 1–50 m standard set; custom on request |
| Insertion loss, single-mode low loss | ≤0.35 dB, typical ≤0.25 dB |
| Insertion loss, single-mode standard | ≤0.75 dB, typical ≤0.40 dB |
| Return loss, single-mode APC | ≥60 dB |
| Wavelength | 1310 / 1550 nm |
| Standards | TIA/EIA-568.3-D, EIA/TIA 604-5, IEC 61754-7, IEC 61753-1, GR-1435-CORE, RoHS |
Notice: Figures are typical and for reference only, not a guarantee. Final IL / RL limits follow the BWNFiber test specification for the selected loss grade. Test method reference: IEC 61300-3-4. Interface and cabling references: IEC 61754-7 / IEC 61753-1 and TIA TIA/EIA-568.3-D.
Selection Guidance
- Conversion cable, not a breakout, not a patch cord. This page remaps MPO to MPO inside the single-mode MPO plant. It does not fan out to LC — for MPO to LC duplex fan-outs see the MPO breakout & harness cable series — and it is not a 1:1 jumper (see the MPO patch cord series).
- APC must mate with APC. Do not mix this cable with PC or UPC ports, cassettes or adapters — the polish mismatch damages end faces and blows the loss budget.
- Polarity is fixed at manufacture and cannot be changed in the field. Choose Type A, B or C at order and re-verify the full channel map (trunks, cassettes, panels) before confirming — a wrong map cannot be re-wired on site. Send the conversion wiring drawing with the inquiry.
- Female (unpinned) on all ends is the default. Pinned trunk and cassette ports take an unpinned conversion cable. If the mating side is unpinned, request a pinned (male) version at inquiry.
- Overall length is measured from the single-count MPO end to the farthest multi-leg MPO end. State this figure, not the leg length, when ordering.
- Need an MPO-12 shell with 8 live fibers? That is sibling model the corresponding configuration in the MPO conversion cable series — choose it when the panel side is keyed for MPO-12.
- For DR4 to LC fan-out, use the breakout family. DR4-to-LC maps stay off this page (source file boundary).
Applications
Use this 8 fiber OS2 conversion cable where a single-mode MPO plant needs port-count conversion while staying in the MPO connector family.
Typical uses:
- OS2 plants that split one 8F MPO port into two MPO-4 ports
- Single-mode fiber maps that stay in the MPO family end to end
- Consolidating two 4-fiber MPO legs onto one 8-fiber panel position (reverse direction of the same map)
- Base-8 single-mode structured cabling through cassettes and adapter panels
Do not use this page for:
- OM3 / OM4 8→2×4 multimode maps — see sibling models in the MPO conversion cable series
- LC DR4 breakout maps — those stay on the MPO breakout & harness cable series
Order Guide
This SKU is not polarity-switchable in the field. Choose polarity from the conversion wiring drawing, then overall length and jacket material. Short BOM lines often write the same map as MPO-8 to 2 MPO-4 OS2.
| Polarity | Part Number | Description |
|---|---|---|
| Type A | BWN-CV-M8APC-2M4APC-OS2-YEL-A-[JKT]-[LEN] | MPO-8/APC (F) to 2 x MPO-4 APC (F) Conversion Cable, 8 Fibers, OS2 Singlemode Yellow — 39 catalog SKUs |
| Type B | BWN-CV-M8APC-2M4APC-OS2-YEL-B-[JKT]-[LEN] | MPO-8/APC (F) to 2 x MPO-4 APC (F) Conversion Cable, 8 Fibers, OS2 Singlemode Yellow — 39 catalog SKUs |
| Type C | BWN-CV-M8APC-2M4APC-OS2-YEL-C-[JKT]-[LEN] | MPO-8/APC (F) to 2 x MPO-4 APC (F) Conversion Cable, 8 Fibers, OS2 Singlemode Yellow — 39 catalog SKUs |
Catalog grid per polarity (13 lengths × 3 jackets = 39 SKUs):
| Length steps | Jacket options |
|---|---|
| 1m (3ft) · 1.5m (5ft) · 2m (7ft) · 3m (10ft) · 5m (16ft) · 7m (23ft) · 10m (33ft) · 15m (49ft) · 20m (66ft) · 25m (82ft) · 30m (98ft) · 40m (131ft) · 50m (164ft) | LSZH / OFNP / OFNR |
Custom lengths between or beyond these steps and pulling eyes are quoted on the drawing.
Why Source from BWNFiber
- Factory-terminated MPO ends on every leg, inspected before shipment
- Conversion map, interface count and live-fiber count are written in the product name, so the BOM matches the shipped hardware
- Lengths from 1 m to 50 m on catalog SKUs, plus project lengths
- Jacket options LSZH, OFNP and OFNR
- OEM print, fiber-map records and IL/RL reports for project handover
- One factory path for catalog SKUs and private-label assemblies
View the complete MPO conversion cable series for related fiber counts, maps and fiber types.
Send the conversion map, polish pair, polarity drawing, jacket and length. BWNFiber returns a build sheet before production.
Frequently Asked Questions
Why APC polish on all ends?
OS2 single-mode MPO in this catalog is APC unless the official name says otherwise. APC must mate with APC — do not plug this cable into PC or UPC ports, cassettes or adapters.
Is this a DR4 to LC breakout cable?
No. DR4-to-LC fan-out maps belong to the breakout and harness family. This cable stays MPO-to-MPO inside the single-mode MPO plant and converts one 8-fiber port into two 4-fiber ports.
Is there an MPO-12 version with 8 live fibers?
Yes — sibling model the corresponding configuration uses an MPO-12/APC shell with 8 live fibers to 2 × MPO-4 APC, OS2. Choose it when the panel side is keyed for MPO-12. Find it in the MPO conversion cable series.
Why female connectors as standard?
Pinned trunk and cassette ports take an unpinned conversion cable, so female is the default on all ends. If the mating side is unpinned, request a pinned (male) version at inquiry.
What lengths are listed?
1 m to 50 m in 13 catalog steps across LSZH, OFNP and OFNR jackets, for polarity Type A, B or C. Custom lengths and pulling eyes are quoted on the drawing.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.