MPO Conversion Cable

MPO-8 to 2x MPO-4 OM3 Conversion Cable

The BWNFiber MPO-8 to 2x MPO-4 OM3 conversion cable regroups one 8-fiber MPO-8/PC female port into two 4-fiber MPO-4/PC female ports on a single aqua OM3 assembly. Use it to split an 8-fiber MPO channel into two 4-fiber groups, or, in the other direction, to merge two 4-fiber MPO groups into one fully used 8-fiber port. Every leg is factory-terminated, labeled for wiring type and optically tested before shipment. Standard lengths run from 1 m to 50 m.

C1.2

Product Overview

The BWNFiber MPO-8 to 2x MPO-4 OM3 conversion cable regroups one 8-fiber MPO-8/PC female port into two 4-fiber MPO-4/PC female ports on a single aqua OM3 assembly. Use it to split an 8-fiber MPO channel into two 4-fiber groups, or, in the other direction, to merge two 4-fiber MPO groups into one fully used 8-fiber port. Every leg is factory-terminated, labeled for wiring type and optically tested before shipment. Standard lengths run from 1 m to 50 m.

A conversion cable stays inside the MPO connector family: it changes how fibers are grouped between MPO ports, not the connector type. If you need one MPO port fanned out to duplex LC legs, that is a breakout (fanout) harness, a different assembly with a different job. This page is the OM3 multimode build with PC polish on every end; for the same 8-to-2×4 map in other fiber types, see the OM4 and OS2 versions in the MPO conversion cable series.

This is a generic MPO assembly built to IEC 61754-7 and TIA/EIA-568.3-D, so it mates with any standards-compliant MPO-8 and MPO-4 ports. If your BOM names a branded connector, tell us in the RFQ and we will quote that build.

Key Features

  • MPO-8/PC female to 2 × MPO-4/PC female: one 8-fiber port remapped onto two 4-fiber MPO ports in the same connector family
  • 8 live fibers, OM3 50/125 µm laser-optimized multimode, aqua jacket
  • PC polish on all three ends: no APC variant in the OM3 multimode catalog
  • Female (unpinned) on every end: mates directly to pinned MPO ports on panels, cassettes and modules
  • Type A, Type B or Type C conversion wiring, factory-built and labeled, not field-changeable
  • Bidirectional passive build: the same cable splits 8F → 2×4F or merges 2×4F → 8F
  • LSZH, OFNP or OFNR jacket; standard lengths 1 m to 50 m, custom lengths on the drawing
  • IL/RL test report per assembly, fiber-map record available for project handover

Technical Specifications

ItemSpecification
Product familyMPO Conversion Cable
Conversion mapMPO-8 → 2 × MPO-4
Connector, single endMPO-8/PC, female (unpinned)
Connector, leg ends2 × MPO-4/PC, female (unpinned)
Active fibers8 (4 + 4)
Fiber typeOM3 multimode, 50/125 µm
Jacket colorAqua
Polish pairPC → PC
Wiring (polarity)Type A / Type B / Type C, per order drawing
Jacket materialLSZH / OFNP / OFNR
Overall length1–50 m standard steps; custom on request
StandardsTIA/EIA-568.3-D, EIA/TIA 604-5, IEC 61754-7, IEC 61753-1, GR-1435-CORE, RoHS

Final insertion loss and return loss limits follow the BWNFiber test specification for the selected loss grade. Test method reference: IEC 61300-3-4.

Selection Guidance

  • Conversion or breakout? A conversion cable regroups fibers between MPO ports (MPO to MPO). A breakout cable changes connector family (MPO to LC legs). If your end devices have duplex LC ports, use the MPO breakout & harness range; if both ends stay MPO, you are on the right page.
  • Split or merge: direction is free. The cable is passive and bidirectional: split one 8-fiber MPO-8 port into two 4-fiber groups, or aggregate two 4-fiber groups into one 8-fiber port so no fiber in the backbone port sits dark.
  • Wiring type is set at the factory. Type A (straight map), Type B (reversed map) and Type C (crossed-pair map) are fixed at termination and cannot be changed in the field. Confirm the fiber map against your site drawing before ordering; we build to the drawing you send.
  • Why female ends? Panels, cassettes and transceiver-class MPO ports carry the guide pins. An unpinned female conversion cable mates to them directly. Pinned (male) builds are quoted on request.
  • Match the fiber grade to the plant. This is the OM3 build: the channel performs to OM3 limits wherever this cable sits in the link. For OM4 plants, use the OM4 conversion version so the whole channel keeps OM4 headroom.
  • How length is measured. Overall length is taken from the single MPO-8 end to the farthest MPO-4 leg end. State leg staggering on the drawing if the two legs land at different distances.
  • Jacket follows the install space. LSZH for enclosed spaces and most European projects, OFNP for plenum spaces, OFNR for riser runs. The local fire code is the deciding factor.

Applications

  • Split one 8-fiber MPO-8 trunk or panel port into two 4-fiber MPO-4 groups inside OM3 multimode plants
  • Aggregate two 4-fiber MPO groups into one 8-fiber MPO port to bring a backbone port to full 8-fiber utilization, with no dark fibers left in the panel
  • Re-partition duplex-pair groups between panels and cassettes: an MPO-8 port carrying four duplex pairs hands two pairs to each MPO-4 leg, without re-terminating the backbone
  • Interface regrouping where installed OM3 cabling presents MPO-8 ports and the connected equipment presents 4-fiber MPO interfaces
  • Base-8 OM3 brownfield rework: regroup existing ports instead of re-pulling cable

Not this product: MPO-to-LC fanout (use a breakout harness), singlemode plants (OS2 version), OM5 wideband builds (OM5 version).

Order Guide

This SKU is built to the ordered wiring type and is not polarity-switchable in the field. Choose the wiring type from the conversion drawing, then jacket material and overall length. Overall length is measured from the single MPO-8 end to the farthest MPO-4 leg end.

WiringPart NumberDescription
Type ABWN-CV-M8PC-2M4PC-OM3-AQ-A-{JKT}-{LEN}MPO-8/PC (F) to 2 × MPO-4/PC (F) conversion cable, 8 fibers, OM3, aqua
Type BBWN-CV-M8PC-2M4PC-OM3-AQ-B-{JKT}-{LEN}MPO-8/PC (F) to 2 × MPO-4/PC (F) conversion cable, 8 fibers, OM3, aqua
Type CBWN-CV-M8PC-2M4PC-OM3-AQ-C-{JKT}-{LEN}MPO-8/PC (F) to 2 × MPO-4/PC (F) conversion cable, 8 fibers, OM3, aqua

Standard lengths: 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m, in LSZH, OFNP or OFNR jacket. Custom lengths between or beyond these steps, staggered legs and pulling eyes are quoted on the drawing.

Why Source from BWNFiber

BWNFiber factory-terminates and inspects every MPO leg before shipment, and the conversion map on the label matches the drawing you approved. Interface count and live-fiber count are written into the product name, so receiving inspection checks the label against the BOM in seconds. Catalog lengths cover 1 m to 50 m, jackets cover LSZH, OFNP and OFNR, and every assembly ships with its IL/RL test report; fiber-map records, OEM printing and private labeling are available for project and distributor orders. Send the conversion map, polish pair, wiring drawing, jacket and length, and BWNFiber returns a build sheet before production.

View the complete MPO conversion cable series for the same 8-to-2×4 map in OM4, OS2 and OM5, and for 12-, 16- and 24-fiber conversion builds.

This page describes a generic MPO assembly built to IEC 61754-7. MTP® is a trademark of US Conec Ltd. Branded connector builds are quoted on request.

FAQ

Frequently Asked Questions

What is an MPO-8 to 2x MPO-4 conversion cable?

A passive factory-terminated assembly that regroups one 8-fiber MPO-8 port into two 4-fiber MPO-4 ports inside the same connector family. This OM3 build uses PC female connectors on all ends, runs 1–50 m, and works in both directions: 8F splitting to 2×4F, or 2×4F merging into 8F.

How is a conversion cable different from a breakout cable?

A conversion cable keeps every leg inside the MPO family and only changes how fibers are grouped; here, one MPO-8 into two MPO-4 ports. A breakout cable changes the connector family, fanning one MPO port out to duplex LC legs. If your end devices use LC ports, see the MPO breakout & harness range.

Is this the cable people call an MPO shuffle cable?

Yes, "shuffle" is the field nickname for assemblies that remap fiber groups between MPO ports. This page is the 8-to-2×4 OM3 shuffle: one MPO-8/PC female to two MPO-4/PC female ports. The same map is available in OM4 and OS2.

Can I change the wiring type in the field?

No. Type A, Type B and Type C conversion maps are fixed at factory termination and labeled on the cable. Confirm the map against your site drawing before ordering; a different map is a different build.

Why are all three ends female (unpinned)?

MPO ports on panels, cassettes and modules carry the alignment pins. An unpinned female cable mates directly to those pinned ports, which is why female is the catalog default on all ends. Pinned builds are quoted on request.

Can I use this OM3 cable in an OM4 plant?

It mates physically, but the link then performs to OM3 limits, since the channel is only as strong as its lowest-grade element. For OM4 plants, order the OM4 conversion version so the channel keeps its OM4 loss and reach headroom.

What lengths and jackets can I order?

Standard lengths run from 1 m to 50 m in thirteen steps, with LSZH, OFNP or OFNR jackets. Custom lengths, staggered legs and pulling eyes are quoted on the drawing.

Is there an OM4 or singlemode version?

Yes. The same 8-to-2×4 conversion map is available as OM4 PC, OM4 mixed APC/PC, OS2 singlemode and OM5 builds. See the MPO conversion cable series for the full range.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.