MPO Conversion Cable

MPO-24 to 3x MPO-8 OS2 Conversion Cable

The BWNFiber MPO-24 to 3x MPO-8 OS2 conversion cable breaks one MPO-24/APC female connector into three MPO-8/APC female connectors, mapping 24 single-mode fibers as 8 + 8 + 8 on a yellow jacket. It lets an installed Base-12 or Base-24 single-mode backbone feed Base-8 equipment ports at full fiber utilization — no dark fibers, no re-cabling. Polarity is factory-built to the conversion wiring drawing (Type A, B or C), and overall length runs 1–50 m or custom.

C5.2

Product Overview

The BWNFiber MPO-24 to 3x MPO-8 OS2 conversion cable breaks one MPO-24/APC female connector into three MPO-8/APC female connectors, mapping 24 single-mode fibers as 8 + 8 + 8 on a yellow jacket. It lets an installed Base-12 or Base-24 single-mode backbone feed Base-8 equipment ports at full fiber utilization — no dark fibers, no re-cabling. Polarity is factory-built to the conversion wiring drawing (Type A, B or C), and overall length runs 1–50 m or custom.

This page describes a single MPO-24 connector on the trunk end — not a 2x MPO-12 fan-out, not an LC breakout, and not an SR4/SR8 jumper. For the multimode OM3 version of the same 24 to 3x 8 map, see the OM3 conversion cable. For straight 24-fiber single-mode links, see the MPO trunk cable family.

Key Features

  1. One MPO-24/APC (F) to three MPO-8/APC (F) — the 24 fibers split as three sequential 8-fiber groups per the conversion wiring drawing.
  2. Full 24-fiber utilization — turns one MPO-24 trunk or panel port into three Base-8 links, with no stranded fibers.
  3. OS2 9/125 µm single-mode, yellow jacket — for telecom, carrier and single-mode data center plants.
  4. APC polish on every end — higher return loss for single-mode links; never mate APC to UPC on the same connection.
  5. Female (unpinned) on all four ends — mates directly to pinned transceiver and panel ports; pinned builds on request.
  6. Polarity Type A, B or C set at factory termination per the conversion drawing — not field-switchable.
  7. Overall length 1–50 m standard set, custom on the drawing — measured from the MPO-24 end to the farthest MPO-8 leg.
  8. LSZH, OFNP or OFNR jacket options — fiber-map record and IL/RL test report available for project handover.

Technical Specifications

ParameterValue
Product familyMPO Conversion Cable
Conversion mapMPO-24 → 3 × MPO-8 (24 = 8 + 8 + 8)
Active fibers24
Fiber typeOS2 single-mode, 9/125 µm
Jacket colorYellow
ConnectorsMPO-24/APC (F) trunk end; 3 × MPO-8/APC (F) leg ends
PolishAPC on all ends
GenderFemale (unpinned) all ends; male (pinned) builds on request
PolarityType A / Type B / Type C, factory-set per conversion wiring drawing
Overall length1–50 m standard set; custom on request
Jacket optionsLSZH / OFNP / OFNR
Insertion lossPer BWNFiber test specification for the selected loss grade
Return lossAPC single-mode grade, per BWNFiber test specification
Test method referenceIEC 61300-3-4
StandardsTIA/EIA-568.3-D, EIA/TIA 604-5 (FOCIS-5), IEC 61754-7, IEC 61753-1, GR-1435-CORE, RoHS

Final IL / RL limits follow the BWNFiber test specification for the selected loss grade. Test method reference: IEC 61300-3-4.

Selection Guidance

  1. When this cable is the right tool. Use it when a 24-fiber single-mode trunk or panel port must serve three 8-fiber (Base-8) equipment ports — typical for 100G/400G DR4-class parallel optics. Patching directly from a Base-12 plant into 8-fiber ports strands 4 of every 12 fibers (33%); the conversion map uses all 24.
  2. One MPO-24, not two MPO-12. Some "24 to 3x 8" assemblies present two MPO-12 connectors on the trunk end. This page is the single-MPO-24 build. Match the trunk-end connector to what is actually on your panel or trunk before ordering.
  3. Conversion cable vs conversion cassette. A cassette moves the same 24 to 3x 8 map into a panel and adds at least one extra mated pair — and its insertion loss — to every channel. A conversion cable integrates the map inside the assembly: no panel space, one fewer mated pair per link. Choose a cassette when the conversion must stay reconfigurable at the panel; choose the cable when the map is fixed at the link.
  4. Polarity is set per the conversion wiring drawing. Type A, B or C is applied across the whole 24 to 3x 8 map at factory termination and cannot be changed in the field. Confirm the drawing against your link design before ordering.
  5. Female ends mate to pinned ports. Transceivers and most panel and cassette MPO ports are pinned; the female (unpinned) ends on this cable mate directly to them. If your design terminates on unpinned ports, note it in the RFQ and ask for pinned builds.
  6. APC on every end. OS2 single-mode MPO in this catalog is APC-polished for return loss on single-mode links. Do not mate APC to UPC on the same connection.
  7. Jacket and length. LSZH for enclosed spaces and most EU projects, OFNP for plenum spaces, OFNR for riser shafts — confirm the local fire code. Overall length is measured from the MPO-24 end to the farthest MPO-8 leg; standard steps run 1–50 m. Runs beyond 50 m are usually better served by the MPO trunk cable family.

Applications

  • Base-12/Base-24 single-mode backbones feeding 100G/400G DR4-class Base-8 transceiver ports at full fiber utilization
  • Data center migration: keep installed 24-fiber OS2 trunks in service and convert at the equipment end instead of re-cabling
  • Structured cabling panels: turn one MPO-24 panel position into three Base-8 equipment links
  • Telecom and carrier single-mode parallel-optics distribution where APC polish is specified

Order Guide

This SKU is not polarity-switchable in the field. Choose the polarity from the conversion wiring drawing, then jacket material and overall length. Overall length is measured from the MPO-24 end to the farthest MPO-8 leg.

PolarityPart NumberDescription
Type ABWN-CV-M24APC-3M8APC-OS2-YEL-A-{JKT}-{LEN}MMPO-24/APC (F) to 3 x MPO-8 APC (F) conversion cable, 24F OS2, yellow
Type BBWN-CV-M24APC-3M8APC-OS2-YEL-B-{JKT}-{LEN}MMPO-24/APC (F) to 3 x MPO-8 APC (F) conversion cable, 24F OS2, yellow
Type CBWN-CV-M24APC-3M8APC-OS2-YEL-C-{JKT}-{LEN}MMPO-24/APC (F) to 3 x MPO-8 APC (F) conversion cable, 24F OS2, yellow

Standard lengths: 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m, in LSZH, OFNP or OFNR. Custom lengths between or beyond these steps, and pulling eyes, are quoted on the drawing.

Why Source from BWNFiber

BWNFiber factory-terminates every MPO end on this assembly and inspects each leg before shipment. The product name carries the conversion map, polish and gender, so the cable on the label matches the drawing. Fiber-map records and IL/RL test reports ship for project handover, and OEM printing is available on project orders. Send the conversion map, polish pair, polarity drawing, jacket and length — BWNFiber returns a build sheet before production.

View the complete MPO Conversion Cable series for the full map range: MPO-8 → 2x MPO-4, MPO-12 → 2x MPO-4, MPO-16 → 2x MPO-8, MPO-24 → 2x MPO-12 and MPO-24 → 3x MPO-8 in OM3, OM4, OM5 and OS2. For straight single-mode links, see the MPO trunk cable family.

FAQ

Frequently Asked Questions

1. Is this the same conversion map as the OM3 version?

Yes — 24 fibers split as 8 + 8 + 8. This page is the OS2 single-mode build with APC polish on a yellow jacket; the OM3 version is PC polish on aqua.

2. Is this an SR4 or SR8 cable?

No. SR4 and SR8 define native 8-fiber and 16-fiber links. This is a 24-fiber conversion assembly that adapts one MPO-24 interface to three 8-fiber MPO ports for Base-8 equipment.

3. What is the difference between this cable and a 2x MPO-12 to 3x MPO-8 harness?

The trunk end. This build presents one MPO-24 connector; the other presents two MPO-12 connectors. Both deliver three 8-fiber legs — choose by the connector that is actually on your trunk or panel.

4. Should I use a conversion cable or a conversion cassette?

A cassette puts the map in the panel and keeps links reconfigurable, at the cost of an extra mated pair — and its insertion loss — on every channel. A conversion cable builds the map into the assembly: no panel space, one fewer mated pair. Fixed links favor the cable; frequently changed panels favor the cassette.

5. Why APC polish on all ends?

OS2 single-mode MPO in this catalog is APC-polished for higher return loss. Never mate APC to UPC on the same connection — check the interface on your equipment before ordering.

6. What lengths are available, and how is length measured?

Standard steps run 1–50 m, with custom lengths quoted on the drawing. Overall length is measured from the single MPO-24 end to the farthest of the three MPO-8 legs.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.