C4.1
MPO-24 to 2x MPO-12 OM4 Conversion Cable
The BWNFiber MPO-24 to 2x MPO-12 OM4 conversion cable maps one 24-fiber MPO PC female connector onto two 12-fiber MPO PC female connectors, so a Base-24 OM4 backbone run lands on two Base-12 ports without re-terminating the trunk. All 24 fibers stay live on OM4 50/125 µm, in a violet jacket, with Type A/B/C conversion wiring built to the confirmed drawing. Catalog lengths run 1–50 m, with project lengths on request.

Product Overview
This conversion cable re-groups fiber count, not connector type: one MPO-24 ferrule on the backbone side, two MPO-12 ferrules on the equipment side, MPO-to-MPO end to end. In the usual map, positions 1–12 of the 24-fiber ferrule land on the first MPO-12 leg and positions 13–24 on the second; the polarity type defines how transmit and receive pairs flip through the link. The exact position map for your build is fixed on the conversion wiring drawing before production.
Use it where a Base-24 OM4 structured cabling plant meets Base-12 hardware — typically cassette, panel or trunk ports — without pulling new cable. It is not an SR4 jumper and not an LC breakout: every one of the 24 fibers stays live into the two 12-fiber legs. If your link is Base-8 end to end, the MPO patch cord family is the right starting point instead. If you are weighing a routed harness against an enclosed module at a panel boundary, see our MPO conversion cable vs module guide.
Key Features
- One MPO-24/PC female to two MPO-12/PC female connectors
- 24 live fibers on OM4 50/125 µm multimode, violet jacket
- Base-24 to two Base-12 re-grouping in one factory-terminated assembly
- Type A, Type B or Type C conversion wiring, fixed at build per approved drawing
- PC polish on all ends; female (unpinned) default, pinned versions on request
- Catalog lengths 1–50 m; custom lengths, staggered legs and pulling-eye builds on the drawing
- LSZH, OFNP or OFNR jacket options for plenum, riser and general indoor spaces
- Factory optical test on every assembly; IL/RL report available per shipment lot
Technical Specifications
| Item | Specification |
|---|---|
| Product family | MPO Conversion Cable |
| Conversion map | MPO-24 → 2 × MPO-12 |
| Connector, single end | MPO-24, PC polish, female (unpinned) |
| Connector, leg ends | 2 × MPO-12, PC polish, female (unpinned) |
| Fiber count | 24 live fibers end to end |
| Fiber type | OM4 50/125 µm multimode |
| Jacket color | Violet |
| Jacket material | LSZH standard; OFNP / OFNR optional |
| Polarity | Type A / Type B / Type C conversion wiring, per approved drawing |
| Overall length | 1–50 m catalog steps; custom on request |
| Insertion loss / Return loss | Per selected loss grade; final limits follow the BWNFiber test specification |
| Standards reference | TIA/EIA-568.3-D, EIA/TIA 604-5, IEC 61754-7, IEC 61753-1, GR-1435-CORE, RoHS |
| Test method reference | IEC 61300-3-4 (insertion loss), IEC 61300-3-6 (return loss) |
Notice: specifications above are catalog references for this configuration and are for reference only, not a guarantee; final limits follow the BWNFiber test specification for the ordered build.
Selection Guidance
- Choose this cable when the backbone side is Base-24 and the access side is Base-12. If both sides are Base-12, a standard MPO trunk cable or patch cord is the simpler build.
- This is a conversion harness, not an SR4 jumper. SR4 links use eight live fibers on Base-8 interfaces; this assembly keeps 24 fibers live into two 12-fiber MPO legs. For Base-8 patching, see the MPO patch cord family.
- Pick polarity from the channel design, not from habit. Type A, B and C conversion wiring map transmit/receive pairs to the two legs differently. If the design does not specify, send the equipment list and BWNFiber confirms the wiring on the conversion drawing before production.
- MPO mate rule: pinned meets unpinned. Female (unpinned) ends on this cable mate with pinned ports on trunks, cassettes and transceiver-side interfaces. Tell us at inquiry if any leg must be pinned.
- Match the jacket to the space: OFNP for plenum, OFNR for riser shafts, LSZH for general indoor and low-smoke requirements. Confirm against local code.
- Overall length is measured from the single MPO-24 end to the farthest MPO-12 leg. Staggered leg lengths are available on the drawing.
- Need singlemode? The OS2 version of this same map is listed separately. Need 24 → 3 × MPO-8 for Base-8 hardware? See the 3-leg conversion version.
Applications
- Splitting a Base-24 OM4 backbone run into two Base-12 links for cassette or panel environments
- Mixed-generation data center cabling where new Base-24 trunks feed existing Base-12 hardware
- Legacy 24-fiber links (such as 100G SR10-style interfaces) re-grouped onto two 12-fiber ports
- High-density OM4 structured cabling in equipment rooms and distribution areas
- Project builds that must ship with a documented fiber-position map and test records
Order Guide
Build your part number as BWN-CV-M24PC-2M12PC-OM4-VIO-{POL}-{JKT}-{LEN}:
| Option | Choices | Notes |
|---|---|---|
| Polarity (POL) | Type A / Type B / Type C | Fixed at build from the approved conversion wiring drawing; not field-switchable |
| Jacket (JKT) | LSZH / OFNP / OFNR | Select by installation space and local code |
| Length (LEN) | 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40, 50 m | Custom lengths between or beyond these steps quoted on the drawing |
Ordering notes:
- Every build starts from a confirmed conversion wiring drawing; the same drawing revision travels with production and test records.
- Pulling eyes, staggered leg lengths, labeling and OEM print are quoted on the drawing.
- Overall length is measured from the single MPO-24 end to the farthest MPO-12 leg end.
Why Source from BWNFiber
- Factory-terminated and optically tested MPO ends on all three legs
- Conversion map, live-fiber count and polish written into the product name, so quotes never mix configurations
- Drawing-first workflow: polarity and position map confirmed with you before production
- Catalog lengths 1–50 m plus project lengths, pulling-eye and labeling options
- LSZH, OFNP and OFNR jacket choices under one part family
- OEM print, fiber-map records and IL/RL reports available for project handover
Send the conversion map, polish pair, polarity requirement, jacket and length. BWNFiber returns a build sheet before production.
Frequently Asked Questions
1. Is this an SR4 cable?
No. SR4 patching uses eight live fibers on Base-8 interfaces. This assembly keeps all 24 fibers live and re-groups them from one MPO-24 into two MPO-12 legs for Base-12 hardware. For SR4 links, use the MPO patch cord family.
2. What is the difference between the 2 × MPO-12 and 3 × MPO-8 versions?
Same 24-fiber source, different leg grouping. The 2 × MPO-12 map serves Base-12 hardware; the 3 × MPO-8 map serves Base-8 hardware. The 3-leg versions are listed on their own pages.
3. Which polarity type should I order?
Match the channel design. Type A, B and C conversion wiring differ in how transmit/receive pairs map to the two legs. If your design does not specify, send the equipment list and BWNFiber confirms the wiring on the conversion drawing before production.
4. Are the connectors pinned or unpinned?
Female (unpinned) on all three ends by default, made to mate with pinned trunk, cassette or transceiver-side ports. Pinned versions are available on request — state it at inquiry.
5. Can I get this map in OS2 singlemode?
Yes. The OS2 version of the MPO-24 → 2 × MPO-12 map is listed separately. This page covers OM4 multimode only.
6. What insertion loss should I expect?
Final IL/RL limits follow the BWNFiber test specification for the selected loss grade, verified per IEC 61300-3-4 and IEC 61300-3-6. State your channel loss budget at inquiry so the correct grade is quoted.
7. How is the overall length measured?
From the single MPO-24 connector end to the farthest MPO-12 leg end. If you specify staggered legs, the drawing defines each leg length separately.
8. Can BWNFiber supply the wiring drawing before order?
Yes. Conversion builds start from a confirmed fiber-position drawing, and that drawing revision is referenced in production and test records.
Related Products