MPO Conversion Cable

MPO-12 to 2x MPO-4 OS2 Conversion Cable, 8 Fibers

An MPO-12 APC ferrule, eight live OS2 fibers, two MPO-4 APC ports — the catalog map for single-mode plants that present a 12-fiber shell but light only eight fibers. Four positions stay dark. Factory-set polarity, lengths from 1 m to 50 m.

C2.2

Product Overview

The BWNFiber MPO-12/APC (F) to 2 x MPO-4 APC (F) Conversion Cable remaps eight live OS2 fibers from one MPO-12 interface into two MPO-4 interfaces on a yellow single-mode jacket. The MPO-12 ferrule terminates eight positions and keeps four positions dark; each MPO-4 leg carries four fibers. Standard lengths run from 1 m to 50 m, with project lengths built to the drawing.

This is a conversion cable: MPO to MPO with a changed interface count. It is not an MPO-to-LC breakout cord, not a same-count trunk or patch cord, and not an 800G transceiver splitter to 2 x MPO-12. Use it when a single-mode plant presents an MPO-12 shell but only needs to light eight fibers into two MPO-4 ports.

Key Features

  • One MPO-12/APC female connector to two MPO-4 APC female connectors
  • 8 live fibers in a 12-fiber ferrule — four positions dark
  • OS2 9/125 μm single-mode, yellow jacket
  • APC polish on all three ends — mate with APC ports only
  • Female (unpinned) connectors on all ends by default
  • Factory-set polarity: Type A, Type B or Type C — not field-switchable
  • 13 stocked lengths from 1 m (3 ft) to 50 m (164 ft); custom lengths and pulling eyes quoted on the drawing
  • Jacket options: LSZH, OFNP and OFNR

Technical Specifications

ItemSpecification
Product familyMPO Conversion Cable
Conversion mapMPO-12 → 2 × MPO-4 (8 live of 12, four positions dark)
InterfaceMPO-12/APC (F) to 2 × MPO-4 APC (F)
Active fibers8
Fiber typeOS2 single-mode, 9/125 μm
Jacket colorYellow
PolishAPC on all ends
GenderFemale (unpinned) on all ends; pinned (male) version quoted on request
PolarityType A / Type B / Type C, fixed at factory per conversion wiring drawing
Insertion lossPer selected loss grade
Return lossConfirmed with the order specification.
Test methodIEC 61300-3-4 (IL) / IEC 61300-3-6 (RL)
Standard lengths1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m
ComplianceTIA/EIA-568.3-D, EIA/TIA-604-5 (FOCIS-5), IEC 61754-7, IEC 61753-1, GR-1435-CORE, RoHS

Final IL/RL limits follow the BWNFiber test specification for the selected loss grade. Confirm the loss budget against the channel design before ordering.

Selection Guidance

  • Choose this map when a single-mode panel or equipment presents an MPO-12 port but the far side needs two MPO-4 ports — eight live fibers, four positions dark.
  • Why the MPO-12 shell? When the panel side is keyed MPO-12, this cable keeps the 12-position interface while lighting only the eight fibers the MPO-4 legs carry. If the panel side is MPO-8, use the MPO-8 to 2x MPO-4 OS2 version in this series instead.
  • This is not a 12-fiber cable. Four positions are dark by design. For 12 live fibers, use a same-count MPO-12 trunk or patch cord — do not order this page against 12-fiber titles.
  • Polarity is not field-switchable. Confirm Type A, Type B or Type C against the conversion wiring drawing before ordering; the drawing governs.
  • Female is the default because transceiver and trunk-side MPO ports are pinned. Request pinned (male) ends only when the mating port is unpinned.
  • Length is measured from the single-count MPO-12 end to the farthest MPO-4 leg. State this figure, not the leg length, when ordering.
  • APC mates with APC only. Do not plug this cable into PC or UPC ports, cassettes or adapters — the polish mismatch damages end faces and breaks the loss budget.
  • Jacket by install space: LSZH for general indoor spaces, OFNP for plenum air-handling spaces, OFNR for vertical riser runs — confirm the local code requirement before selecting.

Applications

  • OS2 plants that present an MPO-12 interface but light eight fibers into two MPO-4 ports
  • Rack-to-rack single-mode links where two 4-fiber MPO-4 positions consolidate onto one 12-position panel port
  • Base-8 single-mode structured cabling through MPO-12 panel positions
  • Migration phases where MPO-4 equipment joins an installed MPO-12 backbone

This page does not cover 12-live-fiber builds (same-count trunks or patch cords), MPO-8 interface maps (see the MPO-8 to 2x MPO-4 OS2 version), or MPO-to-LC breakout builds (see the MPO Breakout / Harness Cable category).

Order Guide

This SKU is not polarity-switchable in the field. Choose polarity from the conversion wiring drawing, then overall length and jacket material. Overall length is measured from the single-count MPO-12 end to the farthest MPO-4 leg. Live count is 8 fibers.

OptionAvailable values
PolarityType A / Type B / Type C (per conversion wiring drawing)
Overall length1m (3ft) · 1.5m (5ft) · 2m (7ft) · 3m (10ft) · 5m (16ft) · 7m (23ft) · 10m (33ft) · 15m (49ft) · 20m (66ft) · 25m (82ft) · 30m (98ft) · 40m (131ft) · 50m (164ft)
Jacket materialLSZH / OFNP / OFNR
Live fiber count8 (four positions dark on the MPO-12 end)

BWN-CV-M12APC-2M4APC-OS2-8F-YEL-{POL}-{JKT}-{LEN} — example: BWN-CV-M12APC-2M4APC-OS2-8F-YEL-B-LSZH-5M

Custom lengths between or beyond these steps and pulling eyes are quoted on the drawing.

Why Source from BWNFiber

  • Factory-terminated MPO ends on every leg, inspected before shipment
  • Interface count and live-fiber count written in the product name — no ambiguity at goods-in
  • Lengths from 1 m to 50 m on catalog SKUs, plus project lengths
  • Jacket options LSZH, OFNP and OFNR
  • OEM print, fiber-map records and IL/RL reports for project handover
  • One factory path for catalog SKUs and private-label assemblies

Send the conversion map, polish pair, polarity drawing, jacket and length. BWNFiber returns a build sheet for confirmation before production.

FAQ

Frequently Asked Questions

1. Why 8 fibers on an MPO-12?

The MPO-12 ferrule terminates eight positions and keeps four dark. Only the eight fibers feeding the two MPO-4 legs are live. Choose this build when the panel or equipment side presents an MPO-12 interface but the far side needs two MPO-4 ports.

2. Is this the same as the MPO-8 to 2x MPO-4 OS2 cable?

No. That build uses an 8-position MPO-8 ferrule with all eight positions live. This build uses a 12-position MPO-12 ferrule with eight live positions and four dark — choose it when the panel side is keyed MPO-12.

3. Is this a DR4-to-LC breakout cable?

No. DR4-to-LC fan-out maps belong to the MPO breakout and harness family. This cable stays MPO-to-MPO and converts one 12-position interface into two 4-position ports.

4. Can I order 12 live fibers on this cable?

No. This build lights eight fibers by design. For 12 live fibers, use a same-count MPO-12 trunk or patch cord.

5. Why APC?

OS2 single-mode MPO in this catalog is APC unless the official name says otherwise. APC must mate with APC — do not plug this cable into PC or UPC ports, cassettes or adapters.

6. What lengths are listed?

Thirteen stocked lengths from 1 m to 50 m across LSZH, OFNP and OFNR jackets, in polarity Type A, B or C. Custom lengths and pulling eyes are quoted on the drawing.

7. Which jacket should I choose — LSZH, OFNP or OFNR?

Match the pathway: LSZH for general indoor spaces, OFNP for plenum air-handling spaces, OFNR for vertical riser runs. Local code governs — confirm before selecting.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.