C2.1
MPO-12 to 2x MPO-4 OM4 Conversion Cable, 8 Fibers
An MPO-to-MPO conversion cable that lands one 8-fiber MPO-12/APC female port on two MPO-4/PC female ports — eight live OM4 fibers, four center positions dark.

Product Overview
This conversion cable runs from one MPO-12/APC female connector to two MPO-4/PC female connectors on a violet OM4 jacket. The 12-position ferrule carries eight live fibers; the four center positions stay dark. It splits four duplex channels into two groups of two, so an OM4 plant that presents an MPO-12 interface can feed two 4-fiber MPO-4 ports without leaving dark fibers in the link path.
Also searched as an MPO shuffle cable or conversion harness, this is an MPO-to-MPO assembly that only changes the fiber map — it never lands on LC. It is not an MPO-to-LC breakout, and not a 12-fiber link. The polish pair is mixed by design: APC on the MPO-12 end, PC on both MPO-4 legs, so verify both mating ports on the channel drawing before ordering. Polarity is factory-wired as Type A, B or C per the conversion drawing and cannot be changed in the field. Overall length runs 1–50 m across 13 stock steps, with custom lengths and pulling eyes quoted on the drawing.
Key Features
- MPO-12/APC female to 2 × MPO-4/PC female — MPO-to-MPO conversion, no LC
- 8 live fibers in a 12-position ferrule; the 4 center positions stay dark
- OM4 50/125 μm multimode, violet jacket
- Mixed polish pair APC → PC — verify both end faces on the channel drawing
- Female (unpinned) on all three ends; pinned builds on request
- Factory-set Type A / B / C polarity per the conversion wiring drawing
- Overall lengths 1–50 m in 13 stock steps; custom lengths and pulling eyes on the drawing
- Serialized IL/RL and fiber-map records available with the shipment
Technical Specifications
| Item | Specification |
|---|---|
| Connector system | Generic MPO |
| Interface | MPO-12 to 2 × MPO-4 |
| Conversion map | 12 → 2×4 — four duplex channels split into two groups of two |
| Active fibers | 8 (four center positions of the 12-position ferrule stay dark) |
| Fiber type | OM4 multimode, 50/125 μm |
| Jacket color | Violet |
| Polish pair | APC on MPO-12 / PC on MPO-4 (mixed by design) |
| Gender | Female (F) on all ends; male (pinned) on request |
| Cable form | 3.0 mm round legs from a short conversion body, typical |
| Jacket rating | LSZH / OFNP / OFNR |
| Polarity | Type A / Type B / Type C, fixed at manufacture per drawing |
| Insertion loss, multimode low loss | ≤0.35 dB, typical ≤0.20 dB |
| Insertion loss, multimode standard | ≤0.60 dB, typical ≤0.35 dB |
| Return loss, multimode | ≥20 dB |
| Operating wavelength | 850 / 1300 nm (OM4 windows) |
| Operating temperature | −20 °C to +70 °C |
| Storage temperature | −40 °C to +85 °C |
| Standard length set | 1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m |
| Standards | TIA/EIA-568.3-D, EIA/TIA 604-5, IEC 61754-7, IEC 61753-1, GR-1435-CORE, RoHS |
Notice: Figures are typical and for reference only, not a guarantee. Final IL / RL limits follow the BWNFiber test specification for the selected loss grade. Test method reference: IEC 61300-3-4.
Selection Guidance
- 8 live fibers, not 12. The MPO-12 ferrule lights eight fibers into the two MPO-4 legs; the four center positions stay dark. If the link needs 12 live fibers, this is not the right assembly.
- Mixed polish pair. APC on the MPO-12 end, PC on the two MPO-4 legs. Confirm which port each end mates with, and never mate APC to PC on the same connection.
- Polarity is fixed at manufacture. Type A / B / C on a conversion cable follows the conversion wiring drawing — it is not the same map as Type A / B / C on a same-interface patch cord. Re-verify the full channel (trunks, cassettes, panels) with the MPO polarity channel design workflow before confirming the method.
- Female (unpinned) on all three ends is the catalog default, because the assembly plugs into pinned modules or pinned adapters. If the mating side is unpinned, request a pinned (male) build at inquiry. Do not mate two pinned ends.
- Length is measured from the single MPO-12 end to the farthest MPO-4 leg.
- Need the same 8-fiber job on an MPO-8 ferrule instead? The MPO-8 to 2x MPO-4 builds sit in the same MPO conversion cable series — match the ferrule to the hardware you plug into.
- For MPO-to-LC fan-out, use the MPO breakout & harness family. This page stays MPO-to-MPO. Weighing a routed conversion cable against an enclosed module? See the conversion cable vs module comparison.
Applications
Use this 12→2×4 OM4 conversion cable when a link starts on 12-position MPO hardware but only eight OM4 fibers are live, and the far end must land on two 4-fiber MPO ports.
Typical uses:
- Splitting one 8-fiber MPO-12 port (four duplex channels) into two 4-fiber MPO-4 links (two duplex channels each)
- Adapting Base-12 panels, cassettes and trunks to MPO-4 interfaces without paying for dark fibers in the link path
- Reusing installed OM4 MPO-12 plant when new equipment presents MPO-4 ports
- High-density data-center rows where one 12-position port feeds two lower-count MPO connections
Do not use this page for:
- Links that need 12 live fibers end to end
- MPO-to-LC duplex fan-out (that is the breakout/harness family)
- 400G/800G SR8-class conversion — that map belongs to the MPO-16 to 2x MPO-8 build in the same series
Order Guide
This SKU is not polarity-switchable in the field. Choose polarity (Type A, B or C) from the conversion wiring drawing, then jacket material and overall length. Overall length is measured from the single-count MPO end to the farthest multi-leg MPO end.
| Product description | Polarity | Lengths (m) | Jacket material |
|---|---|---|---|
| MPO-12/APC (F) to 2 x MPO-4 PC (F) Conversion Cable, 8 Fibers, OM4 Multimode Violet | Type A | 1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 | LSZH / OFNP / OFNR |
| MPO-12/APC (F) to 2 x MPO-4 PC (F) Conversion Cable, 8 Fibers, OM4 Multimode Violet | Type B | 1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 | LSZH / OFNP / OFNR |
| MPO-12/APC (F) to 2 x MPO-4 PC (F) Conversion Cable, 8 Fibers, OM4 Multimode Violet | Type C | 1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 | LSZH / OFNP / OFNR |
Every polarity × jacket × length combination in this matrix is orderable. Custom lengths between or beyond these steps, and pulling eyes, are quoted on the drawing.
BWN-CV-M12APC-2M4PC-OM4-8F-VIO-{POL}-{JKT}-{LEN}
Why Source from BWNFiber
- Factory-terminated MPO ends on every leg, end-face inspected before shipment
- Interface count and live-fiber count are both written in the product name — 8 live fibers, never sold as 12
- Conversion map, polish pair and polarity are confirmed against your drawing before production
- Lengths from 1 m to 50 m on the catalog set, exact project lengths on the drawing
- Jacket options LSZH, OFNP and OFNR
- OEM print, labels, fiber-map records and IL/RL reports for project handover
View the complete MPO conversion cable series for the other maps and fiber types in this family.
Frequently Asked Questions
Why does an MPO-12 title say 8 Fibers?
The ferrule has 12 positions, but only eight fibers are live into the two MPO-4 legs. The four center positions stay dark. The name states the interface and the live count so the cable is never mistaken for a 12-fiber link.
Is this the same as an MPO-8 to 2x MPO-4 conversion cable?
Same 8-fiber job on different hardware. This page uses a 12-position MPO ferrule; the MPO-8 build uses a true 8-position ferrule. Match the ferrule to the panel or cassette you plug into — both builds sit in the same conversion cable series.
Why is the polish APC on one end and PC on the other?
That is the official configuration of this SKU: APC on the MPO-12 end, PC on the two MPO-4 legs. Verify both mating ports before ordering, and never mate APC to PC on one connection.
Can I change polarity or pin gender after installation?
No. The conversion body is factory-wired to Type A, B or C per the drawing, and gender is fixed when the connectors are built. Confirm the channel map before production.
Is this an 800G or SR8 cable?
No. It is an 8-fiber OM4 conversion assembly. SR8-class conversion uses the MPO-16 to 2x MPO-8 map on a different page in this series. Do not order this SKU for an SR8 map.
What lengths are listed?
1 m to 50 m across 13 stock steps, with custom lengths and pulling eyes quoted on the drawing.
Related Products