TBF-I / TBF-II
TBF-I / TBF-II 1F Tight Buffer Fibre
TBF-I / TBF-II 1F Tight Buffer Fibre for indoor building or equipment-room routes at 1F. Confirm jacket and fiber grade before quoting.

Product Value Summary
TBF-I / TBF-II is a single-fiber tight-buffered optical-fiber product family with a nominal 900 µm finished buffer diameter in the supplied draft. It should be evaluated as a buffered fiber component, not automatically as a finished simplex cable with an outer jacket or strength member. The exact model construction, buffer material, color, stripping behavior and approved optical-fiber grade must be confirmed before quotation or publication.
Buyer short answer: Start with the required fiber grade and the downstream termination or cable-integration process. Then confirm whether TBF-I or TBF-II matches the approved coating/buffer construction, stripping requirement, color and reel length. Do not choose between the two model names from weight alone.
Key Features
- One optical fiber per buffered element.
- Nominal 900 µm tight-buffer diameter in the supplied draft.
- Provisional optical-fiber options: G.652.D, G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 and OM4.
- Separate TBF-I and TBF-II construction rows for model-level review.
- Provisional mechanical data keeps long-term and short-term values separate.
- No outer jacket, aramid-yarn strength member, connector or finished-cable diameter is documented in the supplied P139 file.
Product Identity and Construction Boundary
| Item | Supplied draft status | Publication status |
|---|---|---|
| Fiber count | 1F | Publish after engineering confirms the P139 source record |
| Finished buffer diameter | 900 µm nominal | TBC — original specification required |
| Outer jacket | Not documented | Do not imply PVC, LSZH, OFNR or OFNP |
| Strength member | Not documented | Do not imply aramid yarn or other reinforcement |
| Connector | Not documented | Do not imply a connectorized pigtail or patch cord |
| Buffer material | Not documented | TBC — source required |
| Buffer color options | Not documented | TBC — source required |
| Flame or building rating | Not documented | TBC — certification / test evidence required |
This distinction separates P139 from finished 1F simplex indoor cables that add strength members and an outer sheath. If engineering confirms that P139 is instead a finished cable, this page must be reclassified and rewritten before publication.
Provisional Technical Specifications
The values below are transcribed from the supplied P139 V4 draft. They are not cleared for publication because the referenced original record and source-row report were not present in the delivery folder.
| Model | Fiber coating diameter | Tight-buffer diameter | Weight | Tensile, long / short | Crush, long / short | Bend, dynamic / static | Coating strip force | Status |
|---|---|---|---|---|---|---|---|---|
| TBF-I | 245 ± 7 µm | 900 ± 50 µm | 0.9 kg/km | 3 / 6 N | 100 / 500 N per 100 mm | 20D / 10D | ≤13.3 N | TBC — original specification required |
| TBF-II | 500 ± 50 µm | 900 ± 50 µm | 0.7 kg/km | 3 / 6 N | 100 / 500 N per 100 mm | 20D / 10D | ≤13.3 N | TBC — model mapping requires engineering confirmation |
Interpretation boundary: D is treated as the finished tight-buffer diameter only after the source definition is confirmed. The supplied image labels a 250 µm fiber and a tight-buffer layer; it does not verify the provisional TBF-II 500 µm coating entry.
Provisional Optical-Fiber Options
The supplied draft lists the following alternatives. Each order should select one approved grade; values from different rows must not be combined.
| Fiber option | Wavelength | Provisional attenuation data | Bandwidth data | Status |
|---|---|---|---|---|
| G.652.D | 1310 / 1550 nm | Typical 0.36 / 0.22 dB/km; maximum 0.5 / 0.4 dB/km | Not applicable | TBC — source required |
| G.657.A1 | 1310 / 1550 nm | Typical 0.36 / 0.22 dB/km; maximum 0.5 / 0.4 dB/km | Not applicable | TBC — source required |
| G.657.A2 | 1310 / 1550 nm | Typical 0.36 / 0.22 dB/km; maximum 0.5 / 0.4 dB/km | Not applicable | TBC — source required |
| 50/125 | 850 / 1300 nm | Typical 3.0 / 1.0 dB/km; maximum 3.5 / 1.5 dB/km | OFL ≥500 / 500 MHz·km | TBC — grade designation required |
| 62.5/125 | 850 / 1300 nm | Typical 3.0 / 1.0 dB/km; maximum 3.5 / 1.5 dB/km | OFL ≥200 / 500 MHz·km | TBC — grade designation required |
| OM3 | 850 / 1300 nm | Typical 3.0 / 1.0 dB/km; maximum 3.5 / 1.5 dB/km | OFL ≥1500 / 500; EMB ≥2000 MHz·km at 850 nm | TBC — source required |
| OM4 | 850 / 1300 nm | Typical 3.0 / 1.0 dB/km; maximum 3.5 / 1.5 dB/km | OFL ≥3500 / 500; EMB ≥4700 MHz·km at 850 nm | TBC — source required |
The fiber designation defines the optical-fiber option; it does not prove that every listed grade is currently available in both TBF models.
Interfaces and Connector Options
No connector, polish, ferrule, pinning or finished assembly is specified for P139. If the intended deliverable is a pigtail, patch cord or component lead, create a separate order configuration that states the connector family, polish, length, color, labeling and acceptance limits. Do not add connector options to this product page until BWNFiber confirms that they are supplied under this model.
Compatibility and Application Conditions
Potential use must be confirmed against the downstream design. The current evidence supports treating P139 as a candidate buffered-fiber component for integration into protected indoor cable or assembly designs, rather than as a stand-alone building-rated cable.
Before approval, confirm:
- the receiving component, cable or enclosure;
- the fiber holder and stripping-tool range;
- the required strip length and acceptable strip force;
- the termination or splicing process;
- buffer material, color and identification rules;
- the relevant environmental and flame-rating evidence for the final assembly.
How to Select the Correct Configuration
- Define the finished use. State whether the fiber will be integrated into a pigtail, patch cord, passive component, protected equipment lead or another approved assembly.
- Select one fiber grade. Choose the single-mode or multimode grade required by the approved optical design.
- Confirm the TBF model. Match TBF-I or TBF-II to an engineering-approved construction drawing or specification; do not infer the choice from the model label.
- Confirm handling requirements. Record buffer material, color, stripping-tool range, strip length and acceptance method.
- Lock the commercial configuration. State total length, length per reel, quantity, marking and destination.
- Request controlled evidence. Ask for the current datasheet, drawing and applicable inspection or test record for the quoted configuration.
Differences From Related BWNFiber Products
| Product type | What it includes | When it is the better starting point |
|---|---|---|
| P139 TBF-I / TBF-II buffered fiber | A single buffered optical-fiber element; outer jacket and strength member are not documented | When the buyer needs a buffered element for an approved downstream design |
| 1F simplex indoor cable | Buffered fiber plus documented cable-level protection, dimensions and jacket options | When the buyer needs a finished routable cable rather than a component |
| GJFJV / GJFJH indoor cable | A named finished-cable construction with model-specific cable data | When the building pathway, strength member, outer diameter and jacket are part of the order |
| Connectorized pigtail or patch cord | A finished optical assembly with specified connector interface and length | When the order must arrive terminated and ready for the approved interface |
Use Cases
The following are evaluation scenarios, not confirmed P139 application claims:
- integration into an approved pigtail or patch-cord construction;
- protected routing inside equipment or passive optical components;
- integration into a simplex, duplex, distribution or breakout cable design;
- short protected fiber leads where a 900 µm buffered element is specified.
BWNFiber engineering should confirm the final structure, environment, termination method and applicable rating before these uses appear as product claims.
Testing and Quality-Control Requirements
The supplied file does not document a BWNFiber test method, sampling plan, equipment list or acceptance report. Before release, define which of the following applies to the quoted model:
- finished buffer diameter and concentricity inspection;
- attenuation at the specified wavelengths;
- tensile and crush method and acceptance condition;
- dynamic and static bend definition;
- strip-force method, strip length and conditioning;
- buffer shrink-back, color and surface inspection where required;
- reel identification, length verification and traceability.
TBC — BWNFiber must provide the applicable test method, limits, sampling plan and document name.
Packaging and Procurement Information
| Procurement field | Required order input |
|---|---|
| Product / model | TBF-I or TBF-II, after engineering confirmation |
| Fiber count | 1F |
| Fiber grade | Select one approved grade |
| Buffer diameter | Confirm the approved nominal and tolerance |
| Buffer material and color | TBC — buyer requirement plus BWNFiber availability |
| Reel length | TBC — source required |
| Quantity | Buyer to provide |
| Marking / label | Buyer to provide; BWNFiber capability TBC |
| Destination | Buyer to provide |
| Required documents | Datasheet, drawing, inspection/test record or compliance evidence as applicable |
MOQ, price, availability, lead time, warranty and standard packing are TBC — quotation required.
Required Information for an RFQ
Send BWNFiber:
- TBF-I or TBF-II reference, if already approved;
- selected fiber grade and wavelength requirements;
- required coating and finished buffer diameters;
- buffer material and color;
- downstream cable, pigtail, component or termination process;
- stripping-tool range, strip length and any strip-force requirement;
- total length, reel length and quantity;
- marking, label, packing and destination requirements;
- drawing, BOM, reference specification or acceptance plan when available.
Datasheet, Drawing and Test-Record Area
- Current product datasheet: TBC — source required
- Model construction drawing: TBC — source required
- Optical and mechanical test method: TBC — source required
- Lot or reel inspection record: TBC — confirm availability
- Compliance / fire-rating evidence: TBC — do not claim without model-level documentation
RFQ / CTA
Request a TBF Specification Review
Send the intended downstream use, fiber grade, buffer construction, color, stripping requirement, reel length and quantity. BWNFiber can then confirm whether TBF-I or TBF-II matches the request and identify the datasheet, drawing and test evidence available for the quoted configuration.
Primary CTA label: Request a TBF Specification Review
Secondary CTA label: Send a Drawing or BOM
Frequently Asked Questions
Is P139 a finished indoor fiber-optic cable?
Not on the current evidence. The supplied file documents a single tight-buffered fiber element but does not document an outer jacket, strength member or finished-cable diameter. Treat it as a component until BWNFiber engineering confirms the product classification.
What is the difference between 250 µm coating and 900 µm tight buffer?
They describe different layers. The primary coating protects the glass fiber, while the larger tight buffer is an additional polymer layer around the coated fiber. The exact construction and material must match the approved product specification.
What is the difference between TBF-I and TBF-II?
The supplied draft shows different provisional coating-diameter and weight rows, but the original specification was not included. BWNFiber must confirm the model mapping before the difference is used for selection or publication.
Can I select G.652.D, G.657.A1 or G.657.A2?
Those single-mode options appear in the supplied draft, but current availability under each TBF model is not verified. Select one grade and ask BWNFiber to confirm it against the quoted model and source specification.
Are multimode 50/125, 62.5/125, OM3 and OM4 options available?
They are listed provisionally in the supplied draft. The exact grade designation, bandwidth values, color and model availability require the original datasheet and engineering approval.
Does 20D / 10D define the fiber’s intrinsic bend performance?
No. In the provisional mechanical table it is a product-level dynamic/static bend expression. It must not be substituted for a fiber-grade macrobend specification or a finished-cable bend limit.
Which connector is compatible with this product?
No connector is specified. Compatibility depends on the downstream assembly, ferrule or termination process and the prepared fiber dimensions. Confirm the complete assembly design before ordering.
Is this product LSZH, PVC, riser or plenum rated?
The supplied P139 file does not verify any of those materials or ratings. Do not infer a building rating from the term “tight buffer”; request model-level material and test evidence.
What test records should a buyer request?
Request only the records applicable to the approved configuration, such as dimensional inspection, wavelength-specific attenuation, mechanical test results, strip-force testing and reel traceability. BWNFiber must confirm the available record and test method.
What information is needed for an accurate quotation?
Provide the selected model and fiber grade, buffer construction, color, downstream use, strip requirement, total length, reel length, quantity, marking, destination and any drawing or acceptance plan.
Related Products