Indoor Fiber Cable

TBF-I / TBF-II 1F Tight Buffer Fibre

TBF-I / TBF-II 1F Tight Buffer Fibre for indoor building or equipment-room routes at 1F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

TBF-I / TBF-II

Product Value Summary

TBF-I / TBF-II is a single-fiber tight-buffered optical-fiber product family with a nominal 900 µm finished buffer diameter in the supplied draft. It should be evaluated as a buffered fiber component, not automatically as a finished simplex cable with an outer jacket or strength member. The exact model construction, buffer material, color, stripping behavior and approved optical-fiber grade must be confirmed before quotation or publication.

Buyer short answer: Start with the required fiber grade and the downstream termination or cable-integration process. Then confirm whether TBF-I or TBF-II matches the approved coating/buffer construction, stripping requirement, color and reel length. Do not choose between the two model names from weight alone.

Key Features

  • One optical fiber per buffered element.
  • Nominal 900 µm tight-buffer diameter in the supplied draft.
  • Provisional optical-fiber options: G.652.D, G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 and OM4.
  • Separate TBF-I and TBF-II construction rows for model-level review.
  • Provisional mechanical data keeps long-term and short-term values separate.
  • No outer jacket, aramid-yarn strength member, connector or finished-cable diameter is documented in the supplied P139 file.

Product Identity and Construction Boundary

ItemSupplied draft statusPublication status
Fiber count1FPublish after engineering confirms the P139 source record
Finished buffer diameter900 µm nominalTBC — original specification required
Outer jacketNot documentedDo not imply PVC, LSZH, OFNR or OFNP
Strength memberNot documentedDo not imply aramid yarn or other reinforcement
ConnectorNot documentedDo not imply a connectorized pigtail or patch cord
Buffer materialNot documentedTBC — source required
Buffer color optionsNot documentedTBC — source required
Flame or building ratingNot documentedTBC — certification / test evidence required

This distinction separates P139 from finished 1F simplex indoor cables that add strength members and an outer sheath. If engineering confirms that P139 is instead a finished cable, this page must be reclassified and rewritten before publication.

Provisional Technical Specifications

The values below are transcribed from the supplied P139 V4 draft. They are not cleared for publication because the referenced original record and source-row report were not present in the delivery folder.

ModelFiber coating diameterTight-buffer diameterWeightTensile, long / shortCrush, long / shortBend, dynamic / staticCoating strip forceStatus
TBF-I245 ± 7 µm900 ± 50 µm0.9 kg/km3 / 6 N100 / 500 N per 100 mm20D / 10D≤13.3 NTBC — original specification required
TBF-II500 ± 50 µm900 ± 50 µm0.7 kg/km3 / 6 N100 / 500 N per 100 mm20D / 10D≤13.3 NTBC — model mapping requires engineering confirmation

Interpretation boundary: D is treated as the finished tight-buffer diameter only after the source definition is confirmed. The supplied image labels a 250 µm fiber and a tight-buffer layer; it does not verify the provisional TBF-II 500 µm coating entry.

Provisional Optical-Fiber Options

The supplied draft lists the following alternatives. Each order should select one approved grade; values from different rows must not be combined.

Fiber optionWavelengthProvisional attenuation dataBandwidth dataStatus
G.652.D1310 / 1550 nmTypical 0.36 / 0.22 dB/km; maximum 0.5 / 0.4 dB/kmNot applicableTBC — source required
G.657.A11310 / 1550 nmTypical 0.36 / 0.22 dB/km; maximum 0.5 / 0.4 dB/kmNot applicableTBC — source required
G.657.A21310 / 1550 nmTypical 0.36 / 0.22 dB/km; maximum 0.5 / 0.4 dB/kmNot applicableTBC — source required
50/125850 / 1300 nmTypical 3.0 / 1.0 dB/km; maximum 3.5 / 1.5 dB/kmOFL ≥500 / 500 MHz·kmTBC — grade designation required
62.5/125850 / 1300 nmTypical 3.0 / 1.0 dB/km; maximum 3.5 / 1.5 dB/kmOFL ≥200 / 500 MHz·kmTBC — grade designation required
OM3850 / 1300 nmTypical 3.0 / 1.0 dB/km; maximum 3.5 / 1.5 dB/kmOFL ≥1500 / 500; EMB ≥2000 MHz·km at 850 nmTBC — source required
OM4850 / 1300 nmTypical 3.0 / 1.0 dB/km; maximum 3.5 / 1.5 dB/kmOFL ≥3500 / 500; EMB ≥4700 MHz·km at 850 nmTBC — source required

The fiber designation defines the optical-fiber option; it does not prove that every listed grade is currently available in both TBF models.

Interfaces and Connector Options

No connector, polish, ferrule, pinning or finished assembly is specified for P139. If the intended deliverable is a pigtail, patch cord or component lead, create a separate order configuration that states the connector family, polish, length, color, labeling and acceptance limits. Do not add connector options to this product page until BWNFiber confirms that they are supplied under this model.

Compatibility and Application Conditions

Potential use must be confirmed against the downstream design. The current evidence supports treating P139 as a candidate buffered-fiber component for integration into protected indoor cable or assembly designs, rather than as a stand-alone building-rated cable.

Before approval, confirm:

  1. the receiving component, cable or enclosure;
  2. the fiber holder and stripping-tool range;
  3. the required strip length and acceptable strip force;
  4. the termination or splicing process;
  5. buffer material, color and identification rules;
  6. the relevant environmental and flame-rating evidence for the final assembly.

How to Select the Correct Configuration

  1. Define the finished use. State whether the fiber will be integrated into a pigtail, patch cord, passive component, protected equipment lead or another approved assembly.
  2. Select one fiber grade. Choose the single-mode or multimode grade required by the approved optical design.
  3. Confirm the TBF model. Match TBF-I or TBF-II to an engineering-approved construction drawing or specification; do not infer the choice from the model label.
  4. Confirm handling requirements. Record buffer material, color, stripping-tool range, strip length and acceptance method.
  5. Lock the commercial configuration. State total length, length per reel, quantity, marking and destination.
  6. Request controlled evidence. Ask for the current datasheet, drawing and applicable inspection or test record for the quoted configuration.

Differences From Related BWNFiber Products

Product typeWhat it includesWhen it is the better starting point
P139 TBF-I / TBF-II buffered fiberA single buffered optical-fiber element; outer jacket and strength member are not documentedWhen the buyer needs a buffered element for an approved downstream design
1F simplex indoor cableBuffered fiber plus documented cable-level protection, dimensions and jacket optionsWhen the buyer needs a finished routable cable rather than a component
GJFJV / GJFJH indoor cableA named finished-cable construction with model-specific cable dataWhen the building pathway, strength member, outer diameter and jacket are part of the order
Connectorized pigtail or patch cordA finished optical assembly with specified connector interface and lengthWhen the order must arrive terminated and ready for the approved interface

Use Cases

The following are evaluation scenarios, not confirmed P139 application claims:

  • integration into an approved pigtail or patch-cord construction;
  • protected routing inside equipment or passive optical components;
  • integration into a simplex, duplex, distribution or breakout cable design;
  • short protected fiber leads where a 900 µm buffered element is specified.

BWNFiber engineering should confirm the final structure, environment, termination method and applicable rating before these uses appear as product claims.

Testing and Quality-Control Requirements

The supplied file does not document a BWNFiber test method, sampling plan, equipment list or acceptance report. Before release, define which of the following applies to the quoted model:

  • finished buffer diameter and concentricity inspection;
  • attenuation at the specified wavelengths;
  • tensile and crush method and acceptance condition;
  • dynamic and static bend definition;
  • strip-force method, strip length and conditioning;
  • buffer shrink-back, color and surface inspection where required;
  • reel identification, length verification and traceability.

TBC — BWNFiber must provide the applicable test method, limits, sampling plan and document name.

Packaging and Procurement Information

Procurement fieldRequired order input
Product / modelTBF-I or TBF-II, after engineering confirmation
Fiber count1F
Fiber gradeSelect one approved grade
Buffer diameterConfirm the approved nominal and tolerance
Buffer material and colorTBC — buyer requirement plus BWNFiber availability
Reel lengthTBC — source required
QuantityBuyer to provide
Marking / labelBuyer to provide; BWNFiber capability TBC
DestinationBuyer to provide
Required documentsDatasheet, drawing, inspection/test record or compliance evidence as applicable

MOQ, price, availability, lead time, warranty and standard packing are TBC — quotation required.

Required Information for an RFQ

Send BWNFiber:

  • TBF-I or TBF-II reference, if already approved;
  • selected fiber grade and wavelength requirements;
  • required coating and finished buffer diameters;
  • buffer material and color;
  • downstream cable, pigtail, component or termination process;
  • stripping-tool range, strip length and any strip-force requirement;
  • total length, reel length and quantity;
  • marking, label, packing and destination requirements;
  • drawing, BOM, reference specification or acceptance plan when available.

Datasheet, Drawing and Test-Record Area

  • Current product datasheet: TBC — source required
  • Model construction drawing: TBC — source required
  • Optical and mechanical test method: TBC — source required
  • Lot or reel inspection record: TBC — confirm availability
  • Compliance / fire-rating evidence: TBC — do not claim without model-level documentation

RFQ / CTA

Request a TBF Specification Review

Send the intended downstream use, fiber grade, buffer construction, color, stripping requirement, reel length and quantity. BWNFiber can then confirm whether TBF-I or TBF-II matches the request and identify the datasheet, drawing and test evidence available for the quoted configuration.

Primary CTA label: Request a TBF Specification Review
Secondary CTA label: Send a Drawing or BOM

FAQ

Frequently Asked Questions

Is P139 a finished indoor fiber-optic cable?

Not on the current evidence. The supplied file documents a single tight-buffered fiber element but does not document an outer jacket, strength member or finished-cable diameter. Treat it as a component until BWNFiber engineering confirms the product classification.

What is the difference between 250 µm coating and 900 µm tight buffer?

They describe different layers. The primary coating protects the glass fiber, while the larger tight buffer is an additional polymer layer around the coated fiber. The exact construction and material must match the approved product specification.

What is the difference between TBF-I and TBF-II?

The supplied draft shows different provisional coating-diameter and weight rows, but the original specification was not included. BWNFiber must confirm the model mapping before the difference is used for selection or publication.

Can I select G.652.D, G.657.A1 or G.657.A2?

Those single-mode options appear in the supplied draft, but current availability under each TBF model is not verified. Select one grade and ask BWNFiber to confirm it against the quoted model and source specification.

Are multimode 50/125, 62.5/125, OM3 and OM4 options available?

They are listed provisionally in the supplied draft. The exact grade designation, bandwidth values, color and model availability require the original datasheet and engineering approval.

Does 20D / 10D define the fiber’s intrinsic bend performance?

No. In the provisional mechanical table it is a product-level dynamic/static bend expression. It must not be substituted for a fiber-grade macrobend specification or a finished-cable bend limit.

Which connector is compatible with this product?

No connector is specified. Compatibility depends on the downstream assembly, ferrule or termination process and the prepared fiber dimensions. Confirm the complete assembly design before ordering.

Is this product LSZH, PVC, riser or plenum rated?

The supplied P139 file does not verify any of those materials or ratings. Do not infer a building rating from the term “tight buffer”; request model-level material and test evidence.

What test records should a buyer request?

Request only the records applicable to the approved configuration, such as dimensional inspection, wavelength-specific attenuation, mechanical test results, strip-force testing and reel traceability. BWNFiber must confirm the available record and test method.

What information is needed for an accurate quotation?

Provide the selected model and fiber grade, buffer construction, color, downstream use, strip requirement, total length, reel length, quantity, marking, destination and any drawing or acceptance plan.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.