Fiber Patch Cord

SN/UPC to LC/UPC Uniboot Patch Cord

Genuine SENKO SN® VSFF to LC/UPC duplex fiber cable for 400G/800G data center, cloud, hyperscale, and Base-2/Base-8 migration cabling.

Genuine SENKO SN® G.657A1 Bend-Insensitive 2.0mm LSZH Uniboot 100% IL/RL Tested Base-2 / Base-8 Ready

What Is an SN/UPC to LC/UPC Uniboot Patch Cord?

An SN/UPC to LC/UPC Uniboot Patch Cord is a hybrid duplex single-mode fiber cable that connects SENKO SN® VSFF interfaces to standard LC/UPC duplex ports.

The SN® connector side is designed for compact, high-density optical connectivity, while the LC/UPC side supports existing single-mode data center, telecom, and optical distribution equipment. This makes the cable useful for projects where customers need to connect next-generation SN® VSFF patching systems with established LC/UPC infrastructure.

This product is designed for high-density Base-2 optical connectivity, compact patching, easier cable routing, and reduced cable congestion.

SENKO SN UPC to LC UPC uniboot fiber patch cord for high density data center cabling

Full view of SN/UPC to LC/UPC Uniboot Patch Cord assembly

Close up of SENKO SN UPC VSFF connector on uniboot patch cord

SENKO SN®/UPC VSFF connector close-up

SENKO SN® VSFF Connector to Standard LC/UPC Infrastructure

Bridge compact next-generation SN® VSFF ports with widely deployed LC/UPC equipment without a full infrastructure refresh.

The SENKO SN® connector is a Very Small Form Factor (VSFF) duplex optical connector that enables significantly higher port density than traditional LC duplex connectivity. By pairing SN®/UPC on one side with LC/UPC on the other, this uniboot patch cord lets network teams:

  • Deploy high-density SN® patching in new racks or panels
  • Retain existing LC/UPC switches, servers, and transceivers
  • Reduce cable bulk with a 2.0mm round duplex uniboot jacket
  • Simplify switch-to-switch and switch-to-server cabling

This is especially valuable in 400G/800G data center builds, Base-2/Base-8 migration, and space-limited high-port-count patch panels.

Why Choose BWNFiber SN to LC UPC Uniboot Patch Cord?

Genuine SENKO SN®/UPC VSFF Connector

Supports compact, high-density optical patching with original SENKO connector quality.

LC/UPC Duplex on the Opposite End

Compatible with standard single-mode LC/UPC equipment already installed in your network.

UPC-to-UPC Polish Configuration

Suitable for standard data center and telecom single-mode links using UPC ferrules.

G.657A1 Bend-Insensitive Fiber

Better routing performance in tight racks, cable managers, and dense cabinets.

2.0mm Round Duplex LSZH Jacket

Reduces cable bulk and helps improve airflow in high-port-count environments.

Uniboot Cable Structure

Cleaner cable management compared to traditional duplex zipcord patch cords.

Push-Pull Operation

Easier insertion and removal in dense patching environments.

100% IL/RL Factory Testing

Each unit can be supplied with an individual quality label showing IL/RL values.

Base-2 / Base-8 Migration Support

Suitable for high-density network architecture transition and parallel optical systems.

Custom Length, Label, Boot, Packaging

Flexible support for project BOMs, OEM requirements, and private-label requests.

SN/UPC – LC/UPC Uniboot G657A1 DX 2.0mm LSZH Patch Cord Specifications

ItemSpecification
Product NameSN/UPC – LC/UPC Uniboot G657A1 DX 2.0mm LSZH Patch Cord
Fiber ModeSingle-mode OS2, 9/125µm
Fiber TypeITU-T G.657A1 bend-insensitive fiber
Fiber CountDuplex, 2 fibers
Connector ASENKO SN® / UPC
Connector BLC / UPC
Polish TypeUPC on both ends
Cable Type2.0mm round duplex cable
Jacket MaterialLSZH
Jacket ColorYellow
Typical Insertion Loss0.05-0.15 dB per channel
Maximum Insertion Loss≤0.30 dB assembly acceptance
Return Loss, UPC Side≥50 dB assembly acceptance; premium target ≥55 dB
Minimum Bend Radius10mm fiber-level reference for G.657A1
Operating Temperature-40°C to +75°C / +85°C depending on project specification
Storage Temperature-40°C to +85°C
Durability500 mating cycles typical
Tensile StrengthApprox. 200N installation tensile strength for 2.0mm round duplex cable
Test StandardsIEC 61300-3-4 for insertion loss; IEC 61300-3-6 for return loss
Compliance ReferenceGR-326-CORE, TIA-568, RoHS, REACH, UL94 V-0 / LSZH material reference

Applications in 400G/800G Data Center and Telecom Cabling

Where is SN to LC UPC Uniboot Patch Cord used?

  • Ultra-high-density data center patching
  • 400G / 800G high-speed optical network cabling
  • Switch-to-switch fiber connections
  • Switch-to-server optical links
  • High-port-count patch panels
  • Optical cassettes and compact fiber management systems
  • Cloud, hyperscale, enterprise, and colocation data centers
  • Telecom central office cabling
  • Optical distribution frames
  • Base-2 / Base-8 architecture migration
  • Space-limited racks where traditional LC duplex cabling is too bulky
SENKO SN UPC VSFF connector with push pull boot for dense patching panels

Push-pull boot detail for dense patching panels

Product Advantages

Compact SN® VSFF to Standard LC/UPC Connectivity

The SN® side supports compact VSFF duplex connectivity, while the LC/UPC side connects to standard LC-based single-mode equipment. This allows network teams to introduce SN® high-density patching without replacing all existing LC/UPC infrastructure.

Cleaner Cable Routing in Dense Racks

The 2.0mm round duplex uniboot cable structure helps reduce cable congestion compared with traditional duplex zipcord patch cords. This is useful in racks where airflow, cable routing, port access, and patching visibility are important.

Suitable for 400G / 800G Cabling Environments

This patch cord is designed for high-density optical connectivity and can be used in 400G / 800G data center cabling environments, especially where compact Base-2 links, high-port-count panels, and equipment-side LC/UPC connections need to be matched.

Factory-Tested IL/RL Performance

Each cable can be supplied with a production label showing serial number, connector type, length, insertion loss, and return loss. The sample label format shows channel-level IL/RL data, including insertion loss values such as 0.12 dB, 0.20 dB, 0.07 dB, and 0.14 dB, with return loss values from 53.1 dB to 55.5 dB.

Custom Built for Project BOMs

BWNFiber can support custom length, polarity, label, boot color, packaging, private label options, and 100% IL/RL test reports before shipment. G.657A1 is standard, while G.657A2 and compact cable structures can be evaluated based on project requirements.

Base-2 / Base-8 Migration Support

Modern data centers are moving toward higher-density optical architectures. The SN® connector is optimized for Base-2 optical links, while Base-8 MPO/MTP systems remain common for parallel 400G/800G transceiver connectivity.

This SN/UPC to LC/UPC Uniboot Patch Cord helps during migration by:

  • Connecting Base-2 SN® breakout ports to LC/UPC endpoint equipment
  • Supporting compact front-panel patching in high-port-count racks
  • Reducing cable congestion when scaling from Base-8 trunking to Base-2 server links
  • Providing a clean upgrade path for hyperscale and cloud facilities

BWNFiber also supplies MPO/MTP trunk cables, SN® cassettes, and LC/UPC breakout panels to support complete migration designs.

LC UPC connector side of SN to LC UPC uniboot patch cord

LC/UPC connector side for existing infrastructure

SN UPC to LC UPC uniboot patch cord with insertion loss and return loss test label

Individual IL/RL test label supplied with each patch cord

Factory IL/RL Testing and Product Label

Every SN/UPC to LC/UPC Uniboot Patch Cord is 100% factory tested before shipment. Customers can request an individual test label attached to each cable showing:

  • Serial number and production batch
  • Connector type and cable length
  • Insertion loss (IL) per channel
  • Return loss (RL) per channel

Typical test results show insertion loss values such as 0.12 dB, 0.20 dB, 0.07 dB, and 0.14 dB, with return loss values from 53.1 dB to 55.5 dB. Full IL/RL test reports are available before shipment for qualified orders.

Customization Options

ItemCustom Options
Cable LengthCustomized length available on request
Fiber TypeG.657A1 standard; G.657A2 optional
Cable Diameter2.0mm standard; 1.6mm or other compact cable structures can be evaluated by project
Jacket MaterialLSZH standard
Jacket ColorYellow standard for single-mode
Connector BrandGenuine SENKO SN® connector
PolarityStandard duplex polarity; custom polarity available on request
Pull Tab / BootStandard push-pull boot; custom boot color or pull-tab length available on request
LabelS/N, length, connector type, IL/RL test data
PackagingIndividual PE bag; OEM label and carton marking available
Test Report100% IL/RL test report available before shipment

Ordering Guide

BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-XXM
Code SectionMeaningAvailable Options
BWNBWNFiber product prefixFixed
SNUPCConnector ASENKO SN® / UPC
LCUPCConnector BLC / UPC
G657A1Fiber typeG.657A1 bend-insensitive single-mode fiber
DXFiber countDuplex, 2 fibers
2.0Cable diameter2.0mm round duplex cable
LSZHJacket materialLSZH, yellow
XXMCable length1M, 2M, 3M, 5M, 10M, or customized

Standard Ordering Examples

Ordering CodeDescription
BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-1MSN/UPC to LC/UPC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 1 meter
BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-3MSN/UPC to LC/UPC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 3 meters
BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-5MSN/UPC to LC/UPC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 5 meters
BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-10MSN/UPC to LC/UPC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 10 meters

How to Request a Quote

To quote the correct SN/UPC to LC/UPC Uniboot Patch Cord, please send:

  1. Connector type: SN/UPC to LC/UPC
  2. Fiber type: G.657A1 or G.657A2 single-mode
  3. Cable diameter: 2.0mm round duplex cable or other compact structure
  4. Jacket material: LSZH
  5. Cable length: 1m / 3m / 5m / 10m / customized
  6. Quantity
  7. Label and packaging requirements
  8. Polarity or equipment-side connection requirements

Send Your BOM to BWNFiber for SN to LC UPC Patch Cord Matching

FAQ

SN/UPC to LC/UPC Uniboot Patch Cord FAQ

1. What is an SN/UPC to LC/UPC Uniboot Patch Cord?

An SN/UPC to LC/UPC Uniboot Patch Cord is a duplex single-mode fiber cable with a genuine SENKO SN®/UPC VSFF connector on one end and a standard LC/UPC duplex connector on the other end.

2. What is this SN to LC UPC patch cord used for?

It is used for high-density data center patching, switch-to-switch links, switch-to-server connections, telecom central office cabling, optical distribution frames, and Base-2/Base-8 migration environments.

3. Is this cable suitable for 400G and 800G networks?

Yes. The product is designed for high-density 400G and 800G optical cabling environments, especially in cloud, hyperscale, enterprise, and colocation data centers.

4. What fiber type is used?

The standard fiber is ITU-T G.657A1 bend-insensitive single-mode fiber. G.657A2 can also be evaluated based on project requirements.

5. What is the cable jacket?

The standard cable jacket is 2.0mm round duplex LSZH, yellow color for single-mode applications.

6. What is the insertion loss of this SN to LC UPC patch cord?

The typical insertion loss is 0.05-0.15 dB per channel, with ≤0.30 dB maximum assembly acceptance.

7. Can BWNFiber provide IL/RL test labels?

Yes. Each cable can be 100% factory tested and supplied with an individual label showing serial number, length, connector type, insertion loss, and return loss values.

8. Can the cable length be customized?

Yes. Standard lengths include 1m, 3m, 5m, and 10m. Customized lengths are available based on project BOMs.

9. Is this product different from the CS/UPC to LC/APC page?

Yes. This page is for SN/UPC to LC/UPC. The previous page is for CS/UPC to LC/APC. The connector type, polish type, target keywords, and application positioning are different.