What Is an SN/UPC to LC/UPC Uniboot Patch Cord?
An SN/UPC to LC/UPC Uniboot Patch Cord is a hybrid duplex single-mode fiber cable that connects SENKO SN® VSFF interfaces to standard LC/UPC duplex ports.
The SN® connector side is designed for compact, high-density optical connectivity, while the LC/UPC side supports existing single-mode data center, telecom, and optical distribution equipment. This makes the cable useful for projects where customers need to connect next-generation SN® VSFF patching systems with established LC/UPC infrastructure.
This product is designed for high-density Base-2 optical connectivity, compact patching, easier cable routing, and reduced cable congestion.


SENKO SN® VSFF Connector to Standard LC/UPC Infrastructure
Bridge compact next-generation SN® VSFF ports with widely deployed LC/UPC equipment without a full infrastructure refresh.
The SENKO SN® connector is a Very Small Form Factor (VSFF) duplex optical connector that enables significantly higher port density than traditional LC duplex connectivity. By pairing SN®/UPC on one side with LC/UPC on the other, this uniboot patch cord lets network teams:
- Deploy high-density SN® patching in new racks or panels
- Retain existing LC/UPC switches, servers, and transceivers
- Reduce cable bulk with a 2.0mm round duplex uniboot jacket
- Simplify switch-to-switch and switch-to-server cabling
This is especially valuable in 400G/800G data center builds, Base-2/Base-8 migration, and space-limited high-port-count patch panels.
Why Choose BWNFiber SN to LC UPC Uniboot Patch Cord?
Genuine SENKO SN®/UPC VSFF Connector
Supports compact, high-density optical patching with original SENKO connector quality.
LC/UPC Duplex on the Opposite End
Compatible with standard single-mode LC/UPC equipment already installed in your network.
UPC-to-UPC Polish Configuration
Suitable for standard data center and telecom single-mode links using UPC ferrules.
G.657A1 Bend-Insensitive Fiber
Better routing performance in tight racks, cable managers, and dense cabinets.
2.0mm Round Duplex LSZH Jacket
Reduces cable bulk and helps improve airflow in high-port-count environments.
Uniboot Cable Structure
Cleaner cable management compared to traditional duplex zipcord patch cords.
Push-Pull Operation
Easier insertion and removal in dense patching environments.
100% IL/RL Factory Testing
Each unit can be supplied with an individual quality label showing IL/RL values.
Base-2 / Base-8 Migration Support
Suitable for high-density network architecture transition and parallel optical systems.
Custom Length, Label, Boot, Packaging
Flexible support for project BOMs, OEM requirements, and private-label requests.
SN/UPC – LC/UPC Uniboot G657A1 DX 2.0mm LSZH Patch Cord Specifications
| Item | Specification |
|---|---|
| Product Name | SN/UPC – LC/UPC Uniboot G657A1 DX 2.0mm LSZH Patch Cord |
| Fiber Mode | Single-mode OS2, 9/125µm |
| Fiber Type | ITU-T G.657A1 bend-insensitive fiber |
| Fiber Count | Duplex, 2 fibers |
| Connector A | SENKO SN® / UPC |
| Connector B | LC / UPC |
| Polish Type | UPC on both ends |
| Cable Type | 2.0mm round duplex cable |
| Jacket Material | LSZH |
| Jacket Color | Yellow |
| Typical Insertion Loss | 0.05-0.15 dB per channel |
| Maximum Insertion Loss | â¤0.30 dB assembly acceptance |
| Return Loss, UPC Side | â¥50 dB assembly acceptance; premium target â¥55 dB |
| Minimum Bend Radius | 10mm fiber-level reference for G.657A1 |
| Operating Temperature | -40°C to +75°C / +85°C depending on project specification |
| Storage Temperature | -40°C to +85°C |
| Durability | 500 mating cycles typical |
| Tensile Strength | Approx. 200N installation tensile strength for 2.0mm round duplex cable |
| Test Standards | IEC 61300-3-4 for insertion loss; IEC 61300-3-6 for return loss |
| Compliance Reference | GR-326-CORE, TIA-568, RoHS, REACH, UL94 V-0 / LSZH material reference |
Applications in 400G/800G Data Center and Telecom Cabling
Where is SN to LC UPC Uniboot Patch Cord used?
- Ultra-high-density data center patching
- 400G / 800G high-speed optical network cabling
- Switch-to-switch fiber connections
- Switch-to-server optical links
- High-port-count patch panels
- Optical cassettes and compact fiber management systems
- Cloud, hyperscale, enterprise, and colocation data centers
- Telecom central office cabling
- Optical distribution frames
- Base-2 / Base-8 architecture migration
- Space-limited racks where traditional LC duplex cabling is too bulky

Product Advantages
Compact SN® VSFF to Standard LC/UPC Connectivity
The SN® side supports compact VSFF duplex connectivity, while the LC/UPC side connects to standard LC-based single-mode equipment. This allows network teams to introduce SN® high-density patching without replacing all existing LC/UPC infrastructure.
Cleaner Cable Routing in Dense Racks
The 2.0mm round duplex uniboot cable structure helps reduce cable congestion compared with traditional duplex zipcord patch cords. This is useful in racks where airflow, cable routing, port access, and patching visibility are important.
Suitable for 400G / 800G Cabling Environments
This patch cord is designed for high-density optical connectivity and can be used in 400G / 800G data center cabling environments, especially where compact Base-2 links, high-port-count panels, and equipment-side LC/UPC connections need to be matched.
Factory-Tested IL/RL Performance
Each cable can be supplied with a production label showing serial number, connector type, length, insertion loss, and return loss. The sample label format shows channel-level IL/RL data, including insertion loss values such as 0.12 dB, 0.20 dB, 0.07 dB, and 0.14 dB, with return loss values from 53.1 dB to 55.5 dB.
Custom Built for Project BOMs
BWNFiber can support custom length, polarity, label, boot color, packaging, private label options, and 100% IL/RL test reports before shipment. G.657A1 is standard, while G.657A2 and compact cable structures can be evaluated based on project requirements.
Base-2 / Base-8 Migration Support
Modern data centers are moving toward higher-density optical architectures. The SN® connector is optimized for Base-2 optical links, while Base-8 MPO/MTP systems remain common for parallel 400G/800G transceiver connectivity.
This SN/UPC to LC/UPC Uniboot Patch Cord helps during migration by:
- Connecting Base-2 SN® breakout ports to LC/UPC endpoint equipment
- Supporting compact front-panel patching in high-port-count racks
- Reducing cable congestion when scaling from Base-8 trunking to Base-2 server links
- Providing a clean upgrade path for hyperscale and cloud facilities
BWNFiber also supplies MPO/MTP trunk cables, SN® cassettes, and LC/UPC breakout panels to support complete migration designs.


Factory IL/RL Testing and Product Label
Every SN/UPC to LC/UPC Uniboot Patch Cord is 100% factory tested before shipment. Customers can request an individual test label attached to each cable showing:
- Serial number and production batch
- Connector type and cable length
- Insertion loss (IL) per channel
- Return loss (RL) per channel
Typical test results show insertion loss values such as 0.12 dB, 0.20 dB, 0.07 dB, and 0.14 dB, with return loss values from 53.1 dB to 55.5 dB. Full IL/RL test reports are available before shipment for qualified orders.
Customization Options
| Item | Custom Options |
|---|---|
| Cable Length | Customized length available on request |
| Fiber Type | G.657A1 standard; G.657A2 optional |
| Cable Diameter | 2.0mm standard; 1.6mm or other compact cable structures can be evaluated by project |
| Jacket Material | LSZH standard |
| Jacket Color | Yellow standard for single-mode |
| Connector Brand | Genuine SENKO SN® connector |
| Polarity | Standard duplex polarity; custom polarity available on request |
| Pull Tab / Boot | Standard push-pull boot; custom boot color or pull-tab length available on request |
| Label | S/N, length, connector type, IL/RL test data |
| Packaging | Individual PE bag; OEM label and carton marking available |
| Test Report | 100% IL/RL test report available before shipment |
Ordering Guide
| Code Section | Meaning | Available Options |
|---|---|---|
| BWN | BWNFiber product prefix | Fixed |
| SNUPC | Connector A | SENKO SN® / UPC |
| LCUPC | Connector B | LC / UPC |
| G657A1 | Fiber type | G.657A1 bend-insensitive single-mode fiber |
| DX | Fiber count | Duplex, 2 fibers |
| 2.0 | Cable diameter | 2.0mm round duplex cable |
| LSZH | Jacket material | LSZH, yellow |
| XXM | Cable length | 1M, 2M, 3M, 5M, 10M, or customized |
Standard Ordering Examples
| Ordering Code | Description |
|---|---|
| BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-1M | SN/UPC to LC/UPC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 1 meter |
| BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-3M | SN/UPC to LC/UPC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 3 meters |
| BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-5M | SN/UPC to LC/UPC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 5 meters |
| BWN-SNUPC-LCUPC-G657A1-DX2.0-LSZH-10M | SN/UPC to LC/UPC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 10 meters |
How to Request a Quote
To quote the correct SN/UPC to LC/UPC Uniboot Patch Cord, please send:
- Connector type: SN/UPC to LC/UPC
- Fiber type: G.657A1 or G.657A2 single-mode
- Cable diameter: 2.0mm round duplex cable or other compact structure
- Jacket material: LSZH
- Cable length: 1m / 3m / 5m / 10m / customized
- Quantity
- Label and packaging requirements
- Polarity or equipment-side connection requirements
Send Your BOM to BWNFiber for SN to LC UPC Patch Cord Matching