Fiber Wall Socket

SJ-FTTH-MN-3-PT Pre-Terminated Fiber Faceplate with SC/APC Pigtail

The SJ-FTTH-MN-3-PT is a pre-terminated FTTH fiber faceplate: a 95 × 90 × 14 mm wall plate supplied with an SC/APC adapter and a factory-terminated transparent G657A1 pigtail. Instead of polishing or splicing a connector at the subscriber’s wall, the installer routes the ready-made pigtail back to the floor distribution point — or splices it to the incoming drop cable with a standard 40–45 mm protection sleeve — and the connection is done. Factory termination gives every outlet a controlled, low-loss SC/APC end-face, which is why pre-terminated plates are the fast option for MDU and hotel projects with hundreds of identical drops.

SJ-FTTH-MN-3-PT Specifications

ModelSJ-FTTH-MN-3-PT
TypePre-terminated fiber faceplate (outlet + adapter + pigtail)
Faceplate dimension95 × 90 × 14 mm
Capacity1 fiber, SC
Adapter1 × SC simplex, SC/APC
PigtailTransparent SC/APC pigtail, G657A1
Pigtail length10–200 m, made to order
Storage fiber typesG657A1, G657A2, G657B3; OM1–OM5
Supported cable structuresRound drop cable; FTTH F8 (FRP / steel); FTTH flat (FRP / steel)
Fusion splice sleeve40–45 mm (for drop-cable splicing option)
Faceplate materialABS + PC
Operating temperature−40 °C to +70 °C
InstallationWall mounting
Packaging16 × 16 × 4 cm

Key Features

  • Factory-terminated SC/APC pigtail — every outlet ships with a polished, inspected APC end-face; no field polishing, no connector consumables on site.
  • Transparent G657A1 pigtail — bend-insensitive fiber in a low-visibility jacket, discreet along baseboards and in living areas.
  • Two ways to build the link — route the pigtail directly to the floor distribution point, or splice it to the incoming drop cable with a 40–45 mm sleeve.
  • Works with all common drop cable structures — round drop, figure-8 (FRP or steel messenger) and flat FRP/steel FTTH cables.
  • Wide fiber compatibility — stores G657A1/A2/B3 single-mode and OM1–OM5 multimode fiber.
  • Rated −40 °C to +70 °C — covers unheated corridors, stairwells and plant rooms as well as living spaces.

Where the SJ-FTTH-MN-3-PT Fits

  • MDU and hotel projects — hundreds of identical subscriber outlets installed to the same quality, without per-room connector work.
  • FTTH home runs — the pigtail runs from the wall plate back to the floor box in one unbroken factory-terminated length.
  • Fast retrofit — replace a copper wall outlet with a fiber outlet without bringing a splicing trailer into the building.

Prefer a field-spliced plate without pigtail? See the SJ-FTTH-MN-3 1-port faceplate (same slim 14 mm design). Need the 86 × 86 mm format or a second fiber? See the SJ-FTTH-MN-1-PT pre-terminated faceplate.

Installation Notes

  • Fix the plate to the wall, route the pigtail along the planned path first, then connect the adapter side — avoid pulling on the terminated connector.
  • If splicing to the drop cable, use a 40–45 mm fusion splice sleeve and seat it in the plate’s sleeve position.
  • Keep pigtail bends above the G657A1 minimum bend radius, especially at wall corners.
  • For general wall-outlet mounting, see how to install a fiber wall socket in your house.

Pre-Terminated Faceplates in the Range

MN-3-PT (this model)MN-1-PT
Faceplate95 × 90 × 14 mm, slim86 × 86 × 22 mm, 86-type
Capacity1 fiber, 1 × SC simplex1–2 fibers, 1–2 × SC simplex
PigtailTransparent SC/APC G657A1Transparent SC/APC G657A1
Best forSlim single-fiber outletsStandard 86 boxes, dual-fiber points

Full range: Fiber Wall Socket category

FAQ

SJ-FTTH-MN-3-PT Pre-Terminated Fiber Faceplate with SC/APC Pigtail FAQ

What is a pre-terminated fiber faceplate?

A wall outlet supplied from the factory with the adapter and a terminated pigtail already fitted. The installer only routes the pigtail and makes at most one splice — no connector polishing or termination work at the wall.

What pigtail lengths are available?

The pigtail is made to order in lengths from 10 to 200 m. Tell us your floor heights and routing distances and we confirm the right lengths per unit.

Why SC/APC?

PON-based FTTH networks standardize on SC/APC for its low reflectance. The pigtail is transparent G657A1 bend-insensitive fiber, discreet in living areas.

Can I splice the pigtail to a drop cable instead of running it to the floor box?

Yes. Splice with a standard 40–45 mm protection sleeve; the plate supports round drop, figure-8 and flat FTTH cable structures.

What is the operating temperature range?

−40 °C to +70 °C, suitable for unheated corridors and plant rooms as well as homes.

Is multimode available?

The design supports G657 single-mode and OM1–OM5 multimode storage fiber; confirm your fiber type when ordering and we build to match.

Do you support project pricing and OEM?

Yes — send unit counts, pigtail lengths and destination to our sales team for a configuration review and quote.