SJ-FTTH-MN-3-PT Specifications
| Model | SJ-FTTH-MN-3-PT |
| Type | Pre-terminated fiber faceplate (outlet + adapter + pigtail) |
| Faceplate dimension | 95 × 90 × 14 mm |
| Capacity | 1 fiber, SC |
| Adapter | 1 × SC simplex, SC/APC |
| Pigtail | Transparent SC/APC pigtail, G657A1 |
| Pigtail length | 10–200 m, made to order |
| Storage fiber types | G657A1, G657A2, G657B3; OM1–OM5 |
| Supported cable structures | Round drop cable; FTTH F8 (FRP / steel); FTTH flat (FRP / steel) |
| Fusion splice sleeve | 40–45 mm (for drop-cable splicing option) |
| Faceplate material | ABS + PC |
| Operating temperature | −40 °C to +70 °C |
| Installation | Wall mounting |
| Packaging | 16 × 16 × 4 cm |
Key Features
- Factory-terminated SC/APC pigtail — every outlet ships with a polished, inspected APC end-face; no field polishing, no connector consumables on site.
- Transparent G657A1 pigtail — bend-insensitive fiber in a low-visibility jacket, discreet along baseboards and in living areas.
- Two ways to build the link — route the pigtail directly to the floor distribution point, or splice it to the incoming drop cable with a 40–45 mm sleeve.
- Works with all common drop cable structures — round drop, figure-8 (FRP or steel messenger) and flat FRP/steel FTTH cables.
- Wide fiber compatibility — stores G657A1/A2/B3 single-mode and OM1–OM5 multimode fiber.
- Rated −40 °C to +70 °C — covers unheated corridors, stairwells and plant rooms as well as living spaces.
Where the SJ-FTTH-MN-3-PT Fits
- MDU and hotel projects — hundreds of identical subscriber outlets installed to the same quality, without per-room connector work.
- FTTH home runs — the pigtail runs from the wall plate back to the floor box in one unbroken factory-terminated length.
- Fast retrofit — replace a copper wall outlet with a fiber outlet without bringing a splicing trailer into the building.
Prefer a field-spliced plate without pigtail? See the SJ-FTTH-MN-3 1-port faceplate (same slim 14 mm design). Need the 86 × 86 mm format or a second fiber? See the SJ-FTTH-MN-1-PT pre-terminated faceplate.
Installation Notes
- Fix the plate to the wall, route the pigtail along the planned path first, then connect the adapter side — avoid pulling on the terminated connector.
- If splicing to the drop cable, use a 40–45 mm fusion splice sleeve and seat it in the plate’s sleeve position.
- Keep pigtail bends above the G657A1 minimum bend radius, especially at wall corners.
- For general wall-outlet mounting, see how to install a fiber wall socket in your house.
Pre-Terminated Faceplates in the Range
| MN-3-PT (this model) | MN-1-PT | |
|---|---|---|
| Faceplate | 95 × 90 × 14 mm, slim | 86 × 86 × 22 mm, 86-type |
| Capacity | 1 fiber, 1 × SC simplex | 1–2 fibers, 1–2 × SC simplex |
| Pigtail | Transparent SC/APC G657A1 | Transparent SC/APC G657A1 |
| Best for | Slim single-fiber outlets | Standard 86 boxes, dual-fiber points |
Full range: Fiber Wall Socket category
