MPO Breakout & Harness Cable

MPO 8F OS2 Type A to LC Simplex Breakout Cable — Low-Loss Configuration

Specify an 8-fiber OS2 Type A MPO-to-LC simplex harness. Review connector mapping, low-loss acceptance criteria and length requirements with BWNFiber.

MPO Breakout & Harness Cable

SEO Title: MPO 8F OS2 Type A LC Simplex Breakout | BWNFiber
Meta Description: Specify an 8-fiber OS2 Type A MPO-to-LC simplex harness. Review connector mapping, low-loss acceptance criteria and length requirements with BWNFiber.
Recommended URL: /products/data-center-solutions/mpo-cabling/mpo-breakout-harness-cable/mpo-8f-os2-type-a-low-loss-to-lc-simplex-breakout-cable/
Primary keyword: MPO 8F OS2 Type A LC simplex breakout cable
Secondary keywords: eight LC UPC simplex connectors; Type A OS2 harness configuration; low-loss MPO acceptance criteria
Review status: MERGE candidate — do not create an independently indexed page until configuration ownership with item 43 is resolved. URL above is conditional, not an instruction to publish.
Evidence status: Supplied product information is not an approved specification. Items marked confirmation with BWNFiber must be confirmed before upload.

Hero

An eight-fiber single-mode harness for individually routed LC connections: one MPO/APC female end, eight LC/UPC simplex ends and a specified Type A wiring requirement. Send the mating-interface drawing and branch schedule for configuration review.

Product Overview

This MPO 8F OS2 Type A LC simplex breakout cable is described in the supplied configuration as a yellow OS2 assembly with eight individual LC/UPC terminations and an MPO/APC female interface. It is intended for a project that specifies Type A wiring and a low-loss MPO grade. The approved drawing must identify each populated MPO position and its corresponding LC branch before the configuration can be released.

Eight simplex connectors describe eight individual fiber terminations. They do not establish four ready-paired duplex channels. The project port schedule defines how those terminations are used. A Type A component label also does not establish the polarity of the complete optical channel.

Browse the MPO breakout and harness cable range when the branch connector or fiber configuration has not yet been selected.

Key Features

  • Supplied configuration: eight active OS2 single-mode fibers and a yellow jacket.
  • MPO/APC female to eight separately identified LC/UPC simplex connectors.
  • Type A is fixed in this configuration request; a different mapping requires a different approved drawing.
  • Low-loss MPO grade is requested; acceptance limits must state measurement scope and conditions.
  • Individual branch scheduling supports separately routed LC adapter positions when the enclosure drawing allows it.
  • Length, jacket, branch protection and labeling are reviewed against the installation requirement.

Technical Specifications

ItemSupplied configuration / release requirement
AssemblyMPO to eight LC simplex terminations
Active fibers8; populated MPO positions and ferrule geometry: confirmation with BWNFiber
FiberOS2, nominal 9/125 μm; exact fiber designation: confirmation with BWNFiber
MPO endAPC, female/unpinned as supplied; mating connector and key orientation require drawing confirmation
Branch ends8 × LC/UPC simplex; branch numbering requires confirmation
WiringType A as supplied; position-to-branch continuity schedule: confirmation with BWNFiber
Loss gradeLow-loss MPO request; this is not a complete-channel loss guarantee
Optical acceptanceMPO/LC insertion loss, return loss, wavelengths, reference method and pass limits: confirmation with BWNFiber
Jacket colorYellow as supplied; production BOM: confirmation with BWNFiber
Overall lengthSource lists 1–50 m; available lengths, tolerance and measurement datums: confirmation with BWNFiber
Branch lengthSource lists 30 / 45 / 60 cm; approved options and measurement datums: confirmation with BWNFiber
Jacket specificationSource lists LSZH, OFNP and OFNR; availability and applicable evidence: confirmation with BWNFiber
ComplianceNo certification or standards-conformity claim approved from the supplied file alone

The source lists MPO insertion loss of ≤0.35 dB maximum and ≤0.25 dB typical. These figures are held for technical review, not offered as verified performance. Confirm whether each value applies to a mated connector pair or another measurement boundary. A typical value must not replace a contractual maximum.

Selection Guidance

Match the connector at each mating point

The MPO end must meet the corresponding APC interface and pin arrangement. Each LC/UPC end must meet a compatible UPC interface. Different polish types at opposite ends of a cable do not mean APC and UPC may be mated together at one connection.

Approve the eight branch assignments

Request a drawing showing the MPO view direction, key orientation, populated positions and LC branch labels. Do not infer the fiber-position numbering from the shorthand “MPO-8.” Use the complete channel design to confirm transmit/receive continuity. See the fiber cable testing guide for broader test planning, subject to technical review of its current recommendations.

Compare configurations before adding a separate SKU

RequirementSelection consequence
Eight separate LC ports and fixed Type A mapReview this configuration against the approved branch drawing
LC duplex pairsSelect a duplex configuration; do not order by connector count alone
A different polarity mapReturn to family selection and request the required drawing
Standard versus low-loss assemblyCompare approved acceptance limits at the same wavelengths and measurement boundaries
A general low-loss OS2 harness already offers Type ATreat this as a variant of that product unless an independent BOM or application distinction is demonstrated

Applications

  • Single-mode adapter-panel distribution where eight LC terminations need individual identification and routing.
  • Replacement of a documented Type A simplex assembly after the existing connector interfaces and continuity map have been checked.
  • A loss-budgeted harness position in an engineered channel, once both connector losses and the full path have been evaluated.

These are conditional selection scenarios, not customer case studies. No Ethernet speed, transceiver family or DR4 compatibility is guaranteed by this product name. For connection architecture comparisons, consult breakout cable versus cassette selection.

Order Guide

Provide the project reference, endpoint part numbers, eight-branch schedule, quantity, overall length, branch lengths, jacket requirement and destination. Keep the Type A requirement and proposed low-loss grade visible on the request. Do not use an unapproved internal order-code pattern as a released part number.

Source-listed length (m)Approximate feet
13.28
1.54.92
26.56
39.84
516.40
722.97
1032.81
1549.21
2065.62
2582.02
3098.43
40131.23
50164.04

Metric dimensions govern the request; feet are rounded conversions, not separate product lengths. All availability remains confirmation with BWNFiber. State whether overall length ends at the connector reference plane or another datum on the drawing.

Custom configuration requests

Send any request for staggered branches, alternative branch protection, pulling provision, printed labels or packaging as a drawing requirement. Source references to 0.9 mm legs, pulling eyes and OEM printing do not establish confirmed capability. Feasibility, minimum order quantity, sample availability and lead time are confirmation with BWNFiber.

Why Source from BWNFiber

Use the quotation review to obtain a consistent configuration record: connector identity, branch mapping, dimensional drawing, optical acceptance criteria and document revision. Request confirmation of which inspection and test records BWNFiber can supply for this assembly; do not assume that a general catalog statement covers the selected configuration.

Quality control and acceptance documents

Before order release, request continuity verification for all eight branches, optical acceptance results linked to the assembly identifier, and the agreed end-face inspection criteria. The test plan should identify wavelengths, reference procedure, connector scope and pass/fail limits. Confirm the applicable test-method edition with the technical reviewer; citing IEC 61300-3-4 alone does not certify a finished cable.

Need a Configuration Review or Sample?

Send BWNFiber the mating-interface drawing, LC branch destinations, length schedule, jacket requirement, quantity and acceptance criteria. Ask for a configuration review and quotation, including confirmation of available documentation. Request a harness configuration review.

FAQ

Image Alt Text

Are the eight LC connectors supplied as four duplex pairs?

The supplied description specifies eight simplex connectors. Confirm any pairing, clips or duplex handling requirement separately.

Does Type A confirm the polarity of the complete link?

No. It is a component wiring requirement. The complete path and endpoint assignments determine channel continuity.

Does MPO-8 identify every populated position?

No. Obtain the ferrule/interface drawing and position-to-branch schedule for this assembly.

Is the MPO connector pinned?

The source specifies female, or unpinned. Confirm the mating side and approved BOM before ordering.

Why are APC and UPC both listed?

They describe different cable ends. The mating interface at each end must match the applicable polish; do not mate APC directly to UPC.

Is low loss a guaranteed total cable loss?

No approved total-assembly limit was supplied. Confirm the individual connector and assembly acceptance boundaries with BWNFiber.

Is the typical insertion-loss figure an acceptance limit?

No. Obtain a specified maximum and test conditions for order acceptance. The source figures remain confirmation with BWNFiber.

Can this cable be ordered for any DR4 module?

No general compatibility claim is made. Supply the exact module and host details, required operating mode and fiber map for review.

Can I change polarity after delivery?

The supplied configuration is factory-fixed Type A. Field reconfiguration is not specified.

How should overall and branch lengths be stated?

Use meters and a drawing with measurement datums and tolerances. Confirm each branch length rather than assuming it equals the assembly length.

Are all listed jackets available and certified?

Availability and supporting evidence are confirmation with BWNFiber. LSZH describes material behavior; it must not be treated as interchangeable evidence for an OFNP or OFNR installation requirement.

What should accompany a sample request?

Send the connector drawing, branch schedule and acceptance criteria along with length, jacket, quantity and destination. Sample availability and delivery timing require quotation confirmation.

Proposed alt, to use only if it matches the prepared photograph: Yellow OS2 breakout cable with one MPO APC connector and eight LC UPC simplex connectors.

No product images generated. Do not describe Type A wiring or measured loss as visually verified by a photograph.

Related Products