This MPO 8F OS2 to LC uniboot breakout cable connects one APC female MPO end to four LC/UPC duplex uniboot terminations. The supplied configuration specifies eight single-mode fibers and a yellow jacket. Confirm the occupied MPO positions, four LC pair assignments and connector dimensions against the intended equipment before ordering.
Key Features
- Eight active fibers arranged as four duplex LC uniboot branches.
- APC female MPO termination and UPC LC terminations at opposite ends; each mating interface must have matching polish and compatible pin configuration.
- OS2 single-mode fiber designation. The exact fiber specification and assembly bend limits require confirmation.
- Yellow jacket specified in the supplied configuration.
- Listed lengths and jacket selections can be submitted for quotation after drawing review.
Technical Specifications
The table records the supplied configuration, not a signed manufacturing specification. Items marked below must be resolved before this page is released.
| Parameter | Supplied configuration / release requirement |
|---|---|
| Product reference | 44; internal source reference, not an approved saleable part number |
| Active fiber count | 8 |
| MPO end | Described as MPO-8/APC, female; ferrule format, occupied positions and key orientation: confirmation with BWNFiber |
| LC end | Four LC/UPC uniboot duplex terminations; connector model and dimensions: confirmation with BWNFiber |
| Fiber designation | OS2 single-mode, nominal 9/125 μm designation; manufacturer and ITU-T fiber type: confirmation with BWNFiber |
| Jacket color | Yellow, as supplied |
| Overall length request | Listed metric options from 1 to 50 m; measurement endpoints, tolerance and availability: confirmation with BWNFiber |
| Fanout request | Source lists 30, 45 or 60 cm and a 30 cm default; branch measurement and availability: confirmation with BWNFiber |
| Jacket request | Source lists LSZH, OFNP and OFNR; exact construction and supporting documentation: confirmation with BWNFiber |
| Polarity request | Source lists A/B/C; approve the actual four-pair wiring diagram rather than relying on the letter alone |
| Field reconfiguration | Source states no field polarity switching; connector instructions: confirmation with BWNFiber |
| Insertion loss / return loss | Numerical limits, wavelengths, connector-versus-assembly scope and test records: confirmation with BWNFiber |
| Operating conditions | Installation/operating bend radius, tensile limits and temperature range: confirmation with BWNFiber |
OS2 does not by itself identify the ITU-T fiber subtype or exclude G.657.A2. Specify the required fiber and cable construction in the order. Do not infer an assembly bend radius from the fiber name.
Selection Guidance
Match the four duplex destinations
Eight active fibers provide four duplex pairs. They do not establish a supported Ethernet speed or host breakout mode. Use the following record to agree on the assembly wiring. No fiber-position assignment has been invented here.
| Branch label | MPO positions to LC A / LC B | Destination equipment and port | Approval |
|---|---|---|---|
| P1 | To be supplied on drawing | Buyer to specify | Pending |
| P2 | To be supplied on drawing | Buyer to specify | Pending |
| P3 | To be supplied on drawing | Buyer to specify | Pending |
| P4 | To be supplied on drawing | Buyer to specify | Pending |
Record whether the MPO drawing is viewed from the mating face or cable side, its key orientation and pin state. Verify continuity for each recorded destination. For the complete channel, use the MPO polarity design workflow.
Check the uniboot body against the panel
A duplex uniboot organizes two fibers through a shared boot. It does not guarantee narrower adapter spacing, a pull tab, field reversibility or access in every dense panel. Compare the connector envelope, latch access, branch diameter and clearance to neighboring ports with the panel drawing.
Choose the construction that matches the requirement
| Requirement | Configuration to review | Decision boundary |
|---|---|---|
| Four paired LC destinations, shared boots, single-mode path | This OS2 uniboot configuration | Confirm the fiber BOM and pair map |
| Explicit G.657.A2 requirement | A documented G.657.A2 build | Compare actual BOMs; OS2 alone is not a different fiber technology |
| Separate conventional duplex clips | Standard LC duplex construction | Check boot geometry and service access |
| Multimode path | Matching OM3/OM4 family | This OS2 assembly is not a multimode substitute |
| Protected front-access patching | Cassette-based arrangement | Compare routing, connectors and the complete channel budget |
Browse MPO breakout and harness configurations for other assembly types. For an enclosed alternative, review MPO cassette products.
Applications
Use this configuration for four-pair single-mode distribution where the MPO end, LC/UPC ports and routing dimensions match the approved assembly drawing. It can be considered for panel-to-equipment patching or an OEM harness with four paired destinations.
For a parallel-optics breakout request, provide both transceiver part numbers and the host breakout mode. An eight-fiber count is not sufficient to confirm PSM4 or DR4 compatibility: connector format, active positions, pin state, polish, lane mapping, optical specifications and loss budget must all match. This page makes no unconditional DR4 compatibility or reach claim.
Order Guide
Prepare one configuration record
- Identify the two endpoints, equipment part numbers and required channel function.
- Agree the occupied MPO positions and P1–P4 LC A/B destinations.
- Specify overall length and each branch length using explicit measurement endpoints and tolerances.
- Supply the required jacket construction, installation location and applicable project requirements.
- Add quantity, destination, labels, acceptance documents and requested delivery date for quotation.
Listed request options
| Field | Options listed in the supplied material |
|---|---|
| Polarity label | Type A, Type B, Type C; each requires a signed map |
| Overall length, m | 1; 1.5; 2; 3; 5; 7; 10; 15; 20; 25; 30; 40; 50 |
| Jacket designation | LSZH; OFNP; OFNR; documentation required |
| Fanout, cm | 30; 45; 60; source default 30 remains subject to confirmation |
The source lists 117 combinations of polarity, overall length and jacket. These are request options, not verified inventory. Metric dimensions govern; feet are rounded reference conversions. For example, 1 m ≈ 3.28 ft and 2 m ≈ 6.56 ft.
Drawing fields for a repeat order
Include the approved part number, BOM revision, fiber identity, end-face view, pair map, connector model, dimensional drawing, jacket documentation and label schedule. Require review of any material or component substitution before a repeat build.
Custom lengths, staggered fanouts, 0.9 mm legs, pulling eyes, OEM printing and packaging are mentioned in the supplied material. Availability and suitability for this uniboot assembly: confirmation with BWNFiber. The proposed source order-code pattern is not a validated SKU and should not be used as a purchase-order identifier until approved.
Quality Control and Test Documentation
Request an acceptance specification for this exact configuration. It should identify continuity/polarity checks, connector inspection, insertion-loss limits, return-loss limits, test wavelengths, reference method and the scope of each result. Keep connector-level limits separate from complete-assembly limits; neither alone establishes the remaining channel margin.
The source names TIA/EIA-568.3-D, IEC 61754-7, IEC 61754-20, IEC 61753-1, IEC 61300-3-4 and RoHS. Their applicable editions, scope and evidence for this assembly are confirmation with BWNFiber. Listing a standard is not a certificate. Factory inspection coverage, per-assembly reports, traceability and sample availability are also confirmation with BWNFiber.
For a US project, identify the actual installation space and required cable rating before selecting a jacket. For Canada or Europe, supply the project’s applicable requirements and documentation needs; do not treat a jacket acronym as universal approval.
Why Source from BWNFiber
Use a configuration-specific inquiry to establish what will be supplied: eight occupied fibers, four LC duplex destinations, an agreed mechanical fit and a documented acceptance basis. Ask BWNFiber to confirm these items in the quotation and drawing before purchase.
For fiber optic manufacturing and fiber optic testing questions, request evidence tied to the proposed BOM and report scope. Production capacity, certification coverage, MOQ, lead time and available records: confirmation with BWNFiber.
Request a Four-Pair Configuration Review
Send your MPO mating interface, four LC destination ports, required fiber specification, overall and branch lengths, jacket requirement, quantity and destination. Ask for the proposed BOM, pair map, connector drawing, loss limits and commercial terms. Contact BWNFiber about this configuration before releasing a purchase order.