MPO Breakout & Harness Cable

MPO 8F OS2 to LC Simplex Type A Cable

Connect one specified MPO interface to eight individually routed LC/UPC simplex ends. This MPO 8F OS2 to LC simplex Type A cable is specified with an MPO/APC female end and a 3.0 mm yellow trunk for installations that need separate LC port assignments.

MPO Breakout & Harness Cable

Connect one specified MPO interface to eight individually routed LC/UPC simplex ends. This MPO 8F OS2 to LC simplex Type A cable is specified with an MPO/APC female end and a 3.0 mm yellow trunk for installations that need separate LC port assignments.

Product Overview

The supplied configuration describes eight OS2 single-mode fibers terminating in eight LC/UPC simplex connectors. Choose this branch arrangement when each LC end needs its own port position, label and routing length. The eight fibers are not an optical power splitter, and the assembly does not convert a transmission protocol or data rate.

The Type A designation describes the requested assembly mapping. It does not, by itself, confirm a complete Method A channel or compatibility with a particular transceiver. Before ordering, reconcile the MPO occupied positions, connector key reference and eight LC destinations on the assembly drawing.

Specification status: This is a drawing-review configuration. The supplied product values and available options need BWNFiber confirmation (confirmation with BWNFiber) before a quotation or production release.

Key Features

  • One MPO/APC female end to eight individually accessible LC/UPC simplex ends.
  • Eight active OS2 single-mode fibers in the supplied configuration.
  • Yellow trunk specified at 3.0 mm diameter; this dimension does not define the branch diameter.
  • Fixed Type A request on this product; a different map requires a separately approved specification.
  • Individual branch identification to match the buyer’s LC port schedule; label format to be agreed.

Applications

Intended installationWhy this configuration may fitCheck before selection
OS2 distribution panel with individual LC positionsSeparate simplex ends can follow the panel’s port scheduleLC polish, occupied MPO positions and destination labels
Harness replacement within a documented single-mode routeThe eight destinations can be compared with the existing assembly drawingMapping and length datums; do not match by jacket color alone
Project-specific rack cabling with separately routed LC endsBranch lengths can be specified for individual port locationsBranch dimensions, bend-radius requirements and handling space

For general family selection, see MPO breakout and harness cables. For channel planning, use the MPO polarity checklist. The equipment interface specification remains the controlling source for compatibility.

Specifications

The following values reproduce the supplied configuration, not independently certified performance. All supplier-specific values require confirmation (confirmation with BWNFiber).

ParameterSupplied configurationConfirmation required
Active fibers8Exact occupied MPO positions and connector interface drawing
MPO terminationMPO-8/APC femaleFerrule/interface definition, key orientation and mating pin state
LC terminations8 × LC/UPC simplexEight separate connectors and branch identification
Fiber classOS2 single-mode, 9/125 μmFiber manufacturer and exact fiber specification if required
PolarityType A, fixed requestPosition-to-branch continuity drawing
Trunk color and diameterYellow, 3.0 mmDiameter tolerance and jacket construction
Overall lengths listed1–50 mLength datum, tolerance and quoted availability
Jacket requestsLSZH, OFNP or OFNRExact construction and applicable documentation
Fanout lengths listed30, 45 or 60 cmReference datum, branch diameter and routing tolerance
Insertion loss / return lossNot supplied numericallyLimits, wavelength, reference method and test scope
Bend radius / tensile loadNot suppliedInstallation and operating limits
Standards / regulatory documentsUnverifiedApplicable editions and product-specific evidence

Interface and mapping review

Do not infer the populated ferrule positions from “8 fibers” alone. Request a connector-end view with the viewing direction and key position marked. Match each populated position to one LC branch label and destination port. Female denotes the specified unpinned MPO side; verify the actual mating interface before assembly selection.

APC is specified at the MPO end and UPC at the LC ends. Verify polish at each mating connection; the two end descriptions do not authorize mating APC and UPC connectors together. OS2 describes the fiber category and does not establish an application-specific reach or supported Ethernet speed.

Compare the branch arrangement

RequirementThis eight-simplex configurationAlternative to review
Eight separately assigned LC positionsFits the stated branch arrangementNo duplex grouping needs to be assumed
Four mechanically paired LC connectionsRequires a different connector arrangementAn approved LC duplex harness
A specified lower insertion-loss limitNo low-loss grade established hereRequest a measured loss grade and its test limits
A specified bend-insensitive fiber or black jacketNot established by this yellow OS2 specificationRequest the exact fiber and jacket construction

Order Guide

Define the eight destinations

Send a port schedule with one row per LC end. Include the branch label, destination panel and port, required reach from the breakout point and any label orientation constraint. BWNFiber must confirm the corresponding MPO position; do not prefill it from a generic Type A sketch.

Select length and jacket

The source lists these metric lengths. Feet are approximate conversions, not additional stock sizes: 1 m (3.28 ft), 1.5 m (4.92 ft), 2 m (6.56 ft), 3 m (9.84 ft), 5 m (16.40 ft), 7 m (22.97 ft), 10 m (32.81 ft), 15 m (49.21 ft), 20 m (65.62 ft), 25 m (82.02 ft), 30 m (98.43 ft), 40 m (131.23 ft) and 50 m (164.04 ft).

State whether the total length is measured between connector reference points and how the fanout length is measured. LSZH, OFNP and OFNR are source-listed requests, not interchangeable approvals. Specify the installation requirement and request documentation for the quoted cable construction.

Customization requests

Custom length, staggered branches, 0.9 mm legs, pulling eyes and OEM labeling appear in the supplied material. Availability and dimensions require BWNFiber confirmation (confirmation with BWNFiber). Keep the baseline Type A map and 3.0 mm trunk explicit when asking about changes; a requested feature is not an approved catalog option.

Quality Control and Ordering Support

For this assembly, ask BWNFiber for a revision-controlled drawing, the approved material specification, an eight-path continuity record and the agreed optical acceptance criteria. Specify whether insertion-loss and return-loss values apply to each connection or to an end-to-end assembly, along with the wavelength and reference method.

Request a sample report showing how the assembly ID, branch labels and test results are linked. Set end-face inspection and packaging requirements in the purchase specification. Actual inspection coverage, report availability and acceptance limits require BWNFiber confirmation (confirmation with BWNFiber); no blanket test or certification claim is made here.

For a quotation, send the mating interface reference, eight-port destination schedule, overall and fanout lengths, jacket requirement, quantity, destination country and required delivery date. Ask for the approved specification and quote-specific MOQ and lead time. Do not infer availability from the source length list.

Compare enclosed distribution using breakout cable versus cassette selection if individual external branches do not fit the installation. Broader architecture choices belong in the MPO cable types guide.

FAQ

MPO 8F OS2 to LC Simplex Type A Cable FAQ

Are these eight simplex ends or four duplex ends?

The supplied configuration specifies eight LC/UPC simplex connectors. If the panel needs four paired duplex connections, request a separately confirmed arrangement and port map.

Does Type A guarantee a Method A channel?

No. Confirm the complete route and the required source-to-destination mapping. The cable designation alone does not describe every component in the channel.

Which MPO positions are populated?

The attachment does not provide a position drawing. Ask BWNFiber to identify every occupied position, the viewing direction and its corresponding LC branch before release.

Is the female MPO end pinned?

The supplied female designation means an unpinned end. Verify the mating connector’s pin state and mechanical interface against the approved drawing.

Is the 3.0 mm dimension the branch diameter?

No. It is the specified trunk diameter. Branch diameter and fanout dimensions must be confirmed separately.

Can I select Type B on this page?

This configuration is specified as Type A. A Type B request requires a separate mapping review rather than a silent order substitution.

Is this a low-loss assembly?

No numerical loss grade is established in the supplied file. State your required limits and request a corresponding test specification.

Are LSZH, OFNP and OFNR interchangeable?

No. Select against the project installation requirements and request evidence for the quoted jacket construction. A jacket name alone is not a compliance certificate.

Can I order a staggered fanout?

You can submit the eight required branch lengths for review. Availability, tolerances and any change to the assembly construction require confirmation.

Is it compatible with my DR4 or PSM4 module?

Compatibility is not established by this product description. Supply the exact module specification, interface and lane map for review; eight fibers alone do not establish compatibility.

Which documents should accompany the quote?

Request the drawing revision, materials, length datums, branch mapping, optical acceptance limits and available report format. Agree which records will accompany the order.

What information is needed to request this configuration?

Send the MPO mating interface, eight LC destinations, lengths, jacket requirement, quantity and delivery location. Request an eight-branch configuration review with those details.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.