Hero
This MPO 8 fiber OS2 to LC duplex breakout cable connects an eight-fiber single-mode assembly to four LC duplex branches. The supplied configuration specifies an APC female MPO end, UPC LC ends and a yellow jacket. Confirm the connector footprint and fiber map against both endpoints before requesting a quotation.
Product Overview
Use this configuration when an OS2 cable route must terminate in four paired LC connections. Eight active fibers provide four two-fiber pairs; they do not by themselves establish four working network links. The selected optics, host breakout mode and transmit-to-receive mapping determine how those pairs are used.
The source calls the connector “MPO-8.” Confirm the physical ferrule format and populated positions on the assembly drawing: an eight-active-fiber configuration can use a 12-position MPO interface. Do not interpret the marketing name as proof of mating compatibility.
Browse the MPO breakout and harness cable range to compare other branch formats. This page covers the four-duplex OS2 configuration; it does not represent every harness in the category.
Key Features
- Eight active single-mode fibers arranged as four LC duplex branches.
- Source-specified APC MPO female connector and LC/UPC branch ends.
- Yellow OS2 jacket for this supplied configuration.
- Drawing-based selection of fiber mapping, overall length and branch geometry.
- A configuration checklist that separates optical fit, physical fit and acceptance requirements.
Technical Specifications
Specification notice: the following source-listed configuration is subject to BWNFiber confirmation (confirmation with BWNFiber). Confirm it in an approved drawing and quotation before ordering.
| Item | Supplied configuration or confirmation requirement |
|---|---|
| Active fiber count | 8 |
| Fiber type | OS2 single-mode, nominal 9/125 μm; exact fiber designation requires confirmation |
| MPO end | Source label: MPO-8/APC female, unpinned; physical format and populated positions require confirmation |
| Branch connectors | 4 × LC/UPC duplex, comprising eight LC fiber terminations |
| Jacket color | Yellow |
| Polarity | Source lists Type A/B/C; approve an explicit MPO-position-to-LC-leg map for the ordered build |
| Overall length | Source lists 1–50 m; available lengths and measurement reference require confirmation |
| Fanout length | Source lists 30 / 45 / 60 cm and a 30 cm default; confirm each leg on the drawing |
| Jacket options | Source lists LSZH, OFNP and OFNR; exact available cable and supporting fire-rating documentation require confirmation |
| Optical loss | MPO and LC insertion-loss limits, return-loss limits, wavelengths and test method: confirmation with BWNFiber |
| Mechanical limits | Cable and branch diameters, bend radius, pull load and temperature limits: confirmation with BWNFiber |
| Compliance | No SKU-specific certification or conformity evidence supplied; confirmation with BWNFiber |
Selection Guidance
Confirm both mating interfaces
The supplied female MPO end has no guide pins and must mate with a compatible pinned MPO interface. Check key orientation and polish at that connection. Each LC/UPC end must connect to an appropriate LC/UPC interface; APC at the MPO end does not make the LC end APC. The cable joins different connector types at opposite ends, not different polishes at one mated junction.
Approve the eight-fiber map
Specify which MPO position reaches each LC connector, identify the two fibers in every duplex branch and label the destination ports. A Type A, B or C label alone is insufficient to document the entire path through adapters, panels and other cords. This supplied SKU is described as factory-fixed, not field polarity-switchable; confirmation with BWNFiber. Use the MPO channel design guide for the full-path design process and the polarity review worksheet to organize the approval record.
Check the optical application separately
A passive harness does not convert wavelength, lane rate or optical signaling. PSM4 and DR4 names do not establish universal compatibility. As an engineering reference, Cisco’s breakout documentation describes module-specific breakout arrangements. Confirm exact module part numbers, far-end optics, host support, connector format and link budget for the actual installation. That reference is not a compatibility approval for this BWNFiber cable.
Compare nearby configurations
| Requirement | Appropriate selection path | Reason |
|---|---|---|
| Eight OS2 fibers landing in four paired LC ports | Review this configuration | Four duplex branches match the requested physical grouping |
| Twelve active OS2 fibers landing in six pairs | Select the full-count OS2 configuration from the parent range | A larger populated-fiber requirement needs a different map |
| Eight individually managed LC fibers | Review a simplex-branch configuration | Branch handling differs even if the total fiber count matches |
| A specified low-loss Type B assembly | Request the separately documented loss grade and mapping | Do not assume its limits apply to this standard configuration |
| OM3 or OM4 multimode optics | Select a matching multimode assembly | OS2 is not a substitute for the required multimode optical path |
Applications
- OS2 panel distribution: route eight allocated fibers to four paired LC panel positions after confirming the panel map.
- Module breakout evaluation: review a candidate parallel single-mode connection only after the complete host and optical interface requirements are known.
- Replacement harness procurement: match an existing approved drawing, branch labels and acceptance limits before treating a replacement as equivalent.
These are selection scenarios, not customer case studies or claims of tested module compatibility.
Order Guide
Send one completed configuration record rather than selecting by cable name alone.
| RFQ field | What to provide |
|---|---|
| Endpoints | Host and module part numbers; panel or adapter details where present |
| Connector drawing | MPO footprint, APC polish, unpinned cable end, occupied fiber positions and key orientation |
| Branch map | Four labeled LC/UPC duplex pairs, individual fiber IDs and destination ports |
| Optical criteria | Maximum permitted assembly loss and required return loss, wavelengths and measurement method |
| Length | Overall dimension, branch lengths, equal or staggered routing and measurement reference |
| Installation | Jacket requirement, destination market, route constraints and required fire-rating documents |
| Commercial details | Quantity, destination, requested delivery date, labels and packaging |
Source-listed length requests
1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m are listed in the supplied file. Availability is confirmation with BWNFiber. Use metric dimensions on the purchase drawing; 1 m is approximately 3.28 ft and 1.5 m approximately 4.92 ft. Rounded feet are reference values, not alternate build dimensions.
Customization requests
The source mentions alternate lengths, 0.9 mm legs, staggered fanout, pulling eyes, OEM print and polarity labels. Feasibility, construction limits and availability are confirmation with BWNFiber. Identify requested deviations explicitly; do not treat them as included options or an approved order code.
Quality and acceptance documents
Before releasing an order, request the signed build drawing, connector and fiber identification, continuity/polarity map and agreed per-path optical acceptance record. Distinguish a connector loss limit from an end-to-end assembly limit. The record should identify wavelengths, reference method, test equipment, sample or batch identity and acceptance criteria.
The source names IEC 61300-3-4 as a test-method reference, but it supplies no test report or agreed edition. Method, limits, test coverage and report availability are confirmation with BWNFiber. Listing a standard is not evidence that this SKU was certified or tested to it. The MPO polarity and loss testing overview provides background; agree the current method and acceptance criteria for this build.
Why Source from BWNFiber
Use the configuration review to establish a clear purchasing baseline: one approved drawing, one branch-label schedule and one set of acceptance requirements. Request confirmation of the proposed build and any exceptions before comparing quotations. This makes differences in optical grade, routing and documentation visible alongside price.
Production capability, sample availability, MOQ, delivery timing and included test documentation are confirmation with BWNFiber for this SKU. No factory test percentage, certification or delivery promise is asserted here.
Need a Configuration Review or Sample?
Request an OS2 four-duplex harness review. Send the endpoint details, fiber map, overall and branch lengths, jacket requirement, quantity and destination. Ask BWNFiber to confirm the assembly specification, quotation scope and available technical documents. Include your required delivery date for assessment.