MPO Breakout & Harness Cable

MPO 8 Fiber OS2 to LC Duplex Breakout Cable

This MPO 8 fiber OS2 to LC duplex breakout cable connects an eight-fiber single-mode assembly to four LC duplex branches. The supplied configuration specifies an APC female MPO end, UPC LC ends and a yellow jacket. Confirm the connector footprint and fiber map against both endpoints before requesting a quotation.

MPO Breakout & Harness Cable

Hero

This MPO 8 fiber OS2 to LC duplex breakout cable connects an eight-fiber single-mode assembly to four LC duplex branches. The supplied configuration specifies an APC female MPO end, UPC LC ends and a yellow jacket. Confirm the connector footprint and fiber map against both endpoints before requesting a quotation.

Product Overview

Use this configuration when an OS2 cable route must terminate in four paired LC connections. Eight active fibers provide four two-fiber pairs; they do not by themselves establish four working network links. The selected optics, host breakout mode and transmit-to-receive mapping determine how those pairs are used.

The source calls the connector “MPO-8.” Confirm the physical ferrule format and populated positions on the assembly drawing: an eight-active-fiber configuration can use a 12-position MPO interface. Do not interpret the marketing name as proof of mating compatibility.

Browse the MPO breakout and harness cable range to compare other branch formats. This page covers the four-duplex OS2 configuration; it does not represent every harness in the category.

Key Features

  • Eight active single-mode fibers arranged as four LC duplex branches.
  • Source-specified APC MPO female connector and LC/UPC branch ends.
  • Yellow OS2 jacket for this supplied configuration.
  • Drawing-based selection of fiber mapping, overall length and branch geometry.
  • A configuration checklist that separates optical fit, physical fit and acceptance requirements.

Technical Specifications

Specification notice: the following source-listed configuration is subject to BWNFiber confirmation (confirmation with BWNFiber). Confirm it in an approved drawing and quotation before ordering.

ItemSupplied configuration or confirmation requirement
Active fiber count8
Fiber typeOS2 single-mode, nominal 9/125 μm; exact fiber designation requires confirmation
MPO endSource label: MPO-8/APC female, unpinned; physical format and populated positions require confirmation
Branch connectors4 × LC/UPC duplex, comprising eight LC fiber terminations
Jacket colorYellow
PolaritySource lists Type A/B/C; approve an explicit MPO-position-to-LC-leg map for the ordered build
Overall lengthSource lists 1–50 m; available lengths and measurement reference require confirmation
Fanout lengthSource lists 30 / 45 / 60 cm and a 30 cm default; confirm each leg on the drawing
Jacket optionsSource lists LSZH, OFNP and OFNR; exact available cable and supporting fire-rating documentation require confirmation
Optical lossMPO and LC insertion-loss limits, return-loss limits, wavelengths and test method: confirmation with BWNFiber
Mechanical limitsCable and branch diameters, bend radius, pull load and temperature limits: confirmation with BWNFiber
ComplianceNo SKU-specific certification or conformity evidence supplied; confirmation with BWNFiber

Selection Guidance

Confirm both mating interfaces

The supplied female MPO end has no guide pins and must mate with a compatible pinned MPO interface. Check key orientation and polish at that connection. Each LC/UPC end must connect to an appropriate LC/UPC interface; APC at the MPO end does not make the LC end APC. The cable joins different connector types at opposite ends, not different polishes at one mated junction.

Approve the eight-fiber map

Specify which MPO position reaches each LC connector, identify the two fibers in every duplex branch and label the destination ports. A Type A, B or C label alone is insufficient to document the entire path through adapters, panels and other cords. This supplied SKU is described as factory-fixed, not field polarity-switchable; confirmation with BWNFiber. Use the MPO channel design guide for the full-path design process and the polarity review worksheet to organize the approval record.

Check the optical application separately

A passive harness does not convert wavelength, lane rate or optical signaling. PSM4 and DR4 names do not establish universal compatibility. As an engineering reference, Cisco’s breakout documentation describes module-specific breakout arrangements. Confirm exact module part numbers, far-end optics, host support, connector format and link budget for the actual installation. That reference is not a compatibility approval for this BWNFiber cable.

Compare nearby configurations

RequirementAppropriate selection pathReason
Eight OS2 fibers landing in four paired LC portsReview this configurationFour duplex branches match the requested physical grouping
Twelve active OS2 fibers landing in six pairsSelect the full-count OS2 configuration from the parent rangeA larger populated-fiber requirement needs a different map
Eight individually managed LC fibersReview a simplex-branch configurationBranch handling differs even if the total fiber count matches
A specified low-loss Type B assemblyRequest the separately documented loss grade and mappingDo not assume its limits apply to this standard configuration
OM3 or OM4 multimode opticsSelect a matching multimode assemblyOS2 is not a substitute for the required multimode optical path

Applications

  • OS2 panel distribution: route eight allocated fibers to four paired LC panel positions after confirming the panel map.
  • Module breakout evaluation: review a candidate parallel single-mode connection only after the complete host and optical interface requirements are known.
  • Replacement harness procurement: match an existing approved drawing, branch labels and acceptance limits before treating a replacement as equivalent.

These are selection scenarios, not customer case studies or claims of tested module compatibility.

Order Guide

Send one completed configuration record rather than selecting by cable name alone.

RFQ fieldWhat to provide
EndpointsHost and module part numbers; panel or adapter details where present
Connector drawingMPO footprint, APC polish, unpinned cable end, occupied fiber positions and key orientation
Branch mapFour labeled LC/UPC duplex pairs, individual fiber IDs and destination ports
Optical criteriaMaximum permitted assembly loss and required return loss, wavelengths and measurement method
LengthOverall dimension, branch lengths, equal or staggered routing and measurement reference
InstallationJacket requirement, destination market, route constraints and required fire-rating documents
Commercial detailsQuantity, destination, requested delivery date, labels and packaging

Source-listed length requests

1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m are listed in the supplied file. Availability is confirmation with BWNFiber. Use metric dimensions on the purchase drawing; 1 m is approximately 3.28 ft and 1.5 m approximately 4.92 ft. Rounded feet are reference values, not alternate build dimensions.

Customization requests

The source mentions alternate lengths, 0.9 mm legs, staggered fanout, pulling eyes, OEM print and polarity labels. Feasibility, construction limits and availability are confirmation with BWNFiber. Identify requested deviations explicitly; do not treat them as included options or an approved order code.

Quality and acceptance documents

Before releasing an order, request the signed build drawing, connector and fiber identification, continuity/polarity map and agreed per-path optical acceptance record. Distinguish a connector loss limit from an end-to-end assembly limit. The record should identify wavelengths, reference method, test equipment, sample or batch identity and acceptance criteria.

The source names IEC 61300-3-4 as a test-method reference, but it supplies no test report or agreed edition. Method, limits, test coverage and report availability are confirmation with BWNFiber. Listing a standard is not evidence that this SKU was certified or tested to it. The MPO polarity and loss testing overview provides background; agree the current method and acceptance criteria for this build.

Why Source from BWNFiber

Use the configuration review to establish a clear purchasing baseline: one approved drawing, one branch-label schedule and one set of acceptance requirements. Request confirmation of the proposed build and any exceptions before comparing quotations. This makes differences in optical grade, routing and documentation visible alongside price.

Production capability, sample availability, MOQ, delivery timing and included test documentation are confirmation with BWNFiber for this SKU. No factory test percentage, certification or delivery promise is asserted here.

Need a Configuration Review or Sample?

Request an OS2 four-duplex harness review. Send the endpoint details, fiber map, overall and branch lengths, jacket requirement, quantity and destination. Ask BWNFiber to confirm the assembly specification, quotation scope and available technical documents. Include your required delivery date for assessment.

FAQ

Image and Schema Handoff

Does eight fibers mean four LC duplex branches?

For this supplied configuration, yes: each duplex branch contains two fiber terminations. Whether each pair forms a supported optical link depends on the endpoints and approved mapping.

Is MPO-8 always a separate eight-position interface?

Do not infer the physical interface from that label. Verify the ferrule footprint and occupied positions; the source has no connector drawing.

Will this harness work with every 400G DR4 module?

No universal compatibility is established. Check both module part numbers, host breakout support, optical signaling, physical interface and end-to-end map before approval.

Can I substitute it for a PSM4 harness without checking the optics?

No. A shared connector shape does not prove matching lane rate, wavelength, receiver limits or host support. Compare the complete optical path.

Should I order Type B by default?

Order the map required by the actual path. Record every MPO position and LC destination; the polarity label does not replace that record.

Can the LC/UPC branches mate with LC/APC adapters and cords?

Do not mate UPC and APC optical end faces. Verify the required LC polish at each branch destination and request a different configuration where needed.

Is this the low-loss version?

The supplied item does not establish a numerical loss grade. Request confirmed assembly and connector limits; do not borrow limits from another product.

Can this replace six LC duplex branches?

It has four duplex branches. A requirement for twelve active fibers and six paired terminations needs a separately mapped assembly.

Is a 30 cm fanout guaranteed?

It is a default stated in the supplied draft, not an approved dimension. Confirm each leg length, tolerance and reference point on the drawing.

Are LSZH, OFNP and OFNR interchangeable choices?

Do not treat them as equivalent approval labels. Specify the installation requirement and request documentation for the exact offered jacket. Availability is confirmation with BWNFiber.

What should accompany a sample request?

Include the intended endpoint map, measurable acceptance criteria and identification requirements. Sample availability and test-document scope are confirmation with BWNFiber.

What determines quotation and lead time?

The confirmed configuration, quantities, component availability, customization and required documents affect the quotation. Ask for a project-specific response; no fixed MOQ or lead time is confirmed.

  • No product images generated or edited. Existing image positions remain reserved in the preview.
  • Proposed main-image filename: mpo-8f-os2-to-lc-duplex-breakout-cable.jpg. Match actual supplied file format; do not rename or convert an image in this task.
  • Proposed alt, only if the prepared photograph shows these details: “Yellow OS2 breakout cable with one MPO connector and four LC duplex branches.”
  • Detail-view alt, only if visible: “LC duplex branches and identification labels on the eight-fiber OS2 harness.”
  • Breadcrumb: Home → Products → Data Center Solutions → MPO Cabling → MPO Breakout & Harness Cable → this product.
  • Product + BreadcrumbList may be considered after final URL, approved specification, real brand/SKU and prepared image URL are confirmed. No invented Offer, price, stock, AggregateRating, review or certification.
  • No Article/HowTo markup for this product. Visible FAQs are for buyers; do not promise FAQ rich results.
  • Preview noindex/nofollow and disabled forms are local review controls, not CMS settings to copy.
Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.