Hero
One MPO/APC female interface to eight FC/UPC simplex branches, specified with eight OS2 fibers and a yellow jacket. Review the occupied MPO positions, FC port assignments and branch dimensions for your installation before ordering.
Product Overview
The MPO 8 fiber OS2 to FC breakout cable is a proposed singlemode assembly for connecting an MPO interface to eight individually assigned FC/UPC ports. Use this configuration when the equipment schedule calls for FC terminations and eight active fibers. The endpoint drawing determines the connection map; the number of fibers alone does not establish equipment compatibility.
This product belongs to the MPO breakout and harness cable range. It addresses a specific FC port requirement within that range. The supplied specification identifies OS2 9/125 μm fiber, MPO/APC female termination and FC/UPC simplex branches. These are proposed configuration details pending the approved BWNFiber drawing — confirmation with BWNFiber.
Key Features
- Eight individually addressable FC/UPC simplex branches for an eight-fiber connection schedule.
- Separate interface definitions for the MPO/APC end and the FC/UPC ends.
- A branch schedule that can tie each connector label to the equipment port and optical test record.
- Overall and branch lengths specified separately to suit the actual rack or instrument layout.
- Ordering information organized around an approved fiber map, instead of an unqualified polarity label.
Technical Specifications
| Parameter | Proposed configuration / confirmation required |
|---|---|
| Active fiber count | 8; occupied MPO positions require a drawing |
| Fiber | OS2 singlemode, 9/125 μm; exact fiber designation confirmation with BWNFiber |
| MPO end | APC, female/unpinned as supplied; housing, ferrule and key orientation confirmation with BWNFiber |
| Branch ends | 8 × FC/UPC simplex; FC key dimensions and mating interface confirmation with BWNFiber |
| Jacket color | Yellow in supplied material; final construction confirmation with BWNFiber |
| Overall length | Source lists 1–50 m and custom requests; range, tolerance and measurement datum confirmation with BWNFiber |
| Branch length | Source lists 30 / 45 / 60 cm and a 30 cm default; no default released until drawing approval — confirmation with BWNFiber |
| Jacket options | Source lists LSZH, OFNP and OFNR; material, rating and supporting documentation confirmation with BWNFiber |
| Fiber routing | Point-to-point map required; Type A/B/C availability and interpretation confirmation with BWNFiber |
| Optical acceptance | IL/RL limits, wavelengths, reference method and report format confirmation with BWNFiber |
| Mechanical limits | Cable diameter, minimum bend radius, tensile limit and temperature range confirmation with BWNFiber |
Selection Guidance
Check the two mating interfaces
Specify the mating MPO port’s pin state, polish and key orientation. For each FC port, record the interface and key dimensions from the equipment documentation. APC at the MPO end and UPC at the FC end describe different ends of this assembly; they do not authorize mating an APC connector directly with a UPC connector.
Approve eight individual paths
Do not infer the occupied ferrule positions from the shorthand “MPO-8.” Ask for the connector drawing and a numbered map. A Type A, B or C selection alone does not tell an installer which numbered FC lead goes to which equipment port.
| FC branch label | MPO position | Destination port | Test-record identifier |
|---|---|---|---|
| FC-01 through FC-08 | Complete each of the eight rows on the approved drawing | Customer port schedule | Match the same branch identifier |
This is a procurement worksheet, not a wiring diagram. No pinout is assigned here. For the complete channel-design process, use the existing MPO channel polarity design guide.
Compare neighboring requirements
| Your requirement | Selection action |
|---|---|
| Eight OS2 fibers ending in eight FC/UPC ports | Review this configuration and its port map |
| Twelve OS2 fibers ending in FC | Request the twelve-fiber configuration; do not substitute an eight-fiber assembly |
| OM3 or OM4 equipment path ending in FC | Review the appropriate multimode configuration |
| LC equipment ports | Select the applicable LC breakout product |
| Polarization-maintaining operation | Request a separately specified PM assembly; OS2 alone does not establish PM performance |
For the broader assembly options, see the existing MPO/MTP fanout range. Family specifications must not be treated as this SKU’s acceptance limits.
Applications
- Connecting an eight-fiber singlemode MPO path to an FC/UPC equipment-port schedule, after interface and routing approval.
- Organizing individual FC connections at a test or instrument panel where the device documentation specifies compatible singlemode interfaces.
- Replacing an existing FC fanout when the replacement drawing, branch reach and port labels match the installation.
These are candidate uses, not customer case studies or verified equipment endorsements. A passive cable does not establish a data rate or enable a transceiver breakout mode. For any DR4 or other parallel-optics request, check the exact equipment model, optical interface and operating mode; this FC-terminated assembly cannot directly plug into an LC port.
Order Guide
Send one complete configuration request
Include the equipment model, mating-port drawing, eight-row fiber map, total length and tolerance, branch lengths, jacket requirement, quantity, destination and requested delivery date. Ask for commercial confirmation of MOQ, lead time, sample availability and final part number.
The source’s proposed code is BWN-BO-M8APCF-8FCUPC-OS2-YEL-{POL}-{JKT}-{LEN}. Code syntax and available combinations are confirmation with BWNFiber; it is not a released stock code.
Specify dimensions without ambiguity
State whether total length includes the fanout, where the reference planes lie and whether branches are equal or staggered. Measure required reach to the actual FC ports. Keep meters as the ordering unit; any feet values are approximate references.
| Length | Approximate feet |
|---|---|
| 1 m | 3.28 ft |
| 1.5 m | 4.92 ft |
| 2 m | 6.56 ft |
| 3 m | 9.84 ft |
| 5 m | 16.40 ft |
| 7 m | 22.97 ft |
| 10 m | 32.81 ft |
| 15 m | 49.21 ft |
| 20 m | 65.62 ft |
| 25 m | 82.02 ft |
| 30 m | 98.43 ft |
| 40 m | 131.23 ft |
| 50 m | 164.04 ft |
Listed lengths reproduce the source’s requested range, subject to confirmation. They are not a stock or delivery promise.
Why Source from BWNFiber
Agree the acceptance record before purchase
For this proposed configuration, ask BWNFiber to confirm the drawing revision, component identifiers, eight-path continuity map and branch labels before accepting a quotation. Request the applicable fiber optic testing plan, including insertion loss and return loss criteria, test wavelengths, reference conditions and traceable record identifiers. Record availability and actual fiber optic manufacturing controls are confirmation with BWNFiber.
IEC 61754-13 addresses the FC-PC connector interface. IEC TR 61282-15 provides guidance for testing MPO-terminated multifiber cabling. These references help frame the engineering review; they do not certify this BWNFiber assembly. The source’s IEC/TIA and RoHS claims require applicable editions and supporting documents before publication as conformity statements.
Confirm customization and installation requirements
Submit requested branch staggering, labels, jacket, packaging and lengths for feasibility review. Do not assume all combinations are available. For North American installations, obtain evidence for any specified plenum or riser rating. For European projects, state the required reaction-to-fire documentation where applicable. An LSZH material description alone does not establish either requirement.
Need a Configuration Review or Sample?