MPO Breakout & Harness Cable

MPO 8 Fiber OS2 to FC Breakout Cable

This product belongs to the MPO breakout and harness cable range. It addresses a specific FC port requirement within that range. The supplied specification identifies OS2 9/125 μm fiber, MPO/APC female termination and FC/UPC simplex branches. These are proposed configuration details pending the approved BWNFiber drawing — confirmation with BWNFiber.

MPO Breakout & Harness Cable

Hero

One MPO/APC female interface to eight FC/UPC simplex branches, specified with eight OS2 fibers and a yellow jacket. Review the occupied MPO positions, FC port assignments and branch dimensions for your installation before ordering.

Product Overview

The MPO 8 fiber OS2 to FC breakout cable is a proposed singlemode assembly for connecting an MPO interface to eight individually assigned FC/UPC ports. Use this configuration when the equipment schedule calls for FC terminations and eight active fibers. The endpoint drawing determines the connection map; the number of fibers alone does not establish equipment compatibility.

This product belongs to the MPO breakout and harness cable range. It addresses a specific FC port requirement within that range. The supplied specification identifies OS2 9/125 μm fiber, MPO/APC female termination and FC/UPC simplex branches. These are proposed configuration details pending the approved BWNFiber drawing — confirmation with BWNFiber.

Key Features

  • Eight individually addressable FC/UPC simplex branches for an eight-fiber connection schedule.
  • Separate interface definitions for the MPO/APC end and the FC/UPC ends.
  • A branch schedule that can tie each connector label to the equipment port and optical test record.
  • Overall and branch lengths specified separately to suit the actual rack or instrument layout.
  • Ordering information organized around an approved fiber map, instead of an unqualified polarity label.

Technical Specifications

ParameterProposed configuration / confirmation required
Active fiber count8; occupied MPO positions require a drawing
FiberOS2 singlemode, 9/125 μm; exact fiber designation confirmation with BWNFiber
MPO endAPC, female/unpinned as supplied; housing, ferrule and key orientation confirmation with BWNFiber
Branch ends8 × FC/UPC simplex; FC key dimensions and mating interface confirmation with BWNFiber
Jacket colorYellow in supplied material; final construction confirmation with BWNFiber
Overall lengthSource lists 1–50 m and custom requests; range, tolerance and measurement datum confirmation with BWNFiber
Branch lengthSource lists 30 / 45 / 60 cm and a 30 cm default; no default released until drawing approval — confirmation with BWNFiber
Jacket optionsSource lists LSZH, OFNP and OFNR; material, rating and supporting documentation confirmation with BWNFiber
Fiber routingPoint-to-point map required; Type A/B/C availability and interpretation confirmation with BWNFiber
Optical acceptanceIL/RL limits, wavelengths, reference method and report format confirmation with BWNFiber
Mechanical limitsCable diameter, minimum bend radius, tensile limit and temperature range confirmation with BWNFiber

Selection Guidance

Check the two mating interfaces

Specify the mating MPO port’s pin state, polish and key orientation. For each FC port, record the interface and key dimensions from the equipment documentation. APC at the MPO end and UPC at the FC end describe different ends of this assembly; they do not authorize mating an APC connector directly with a UPC connector.

Approve eight individual paths

Do not infer the occupied ferrule positions from the shorthand “MPO-8.” Ask for the connector drawing and a numbered map. A Type A, B or C selection alone does not tell an installer which numbered FC lead goes to which equipment port.

FC branch labelMPO positionDestination portTest-record identifier
FC-01 through FC-08Complete each of the eight rows on the approved drawingCustomer port scheduleMatch the same branch identifier

This is a procurement worksheet, not a wiring diagram. No pinout is assigned here. For the complete channel-design process, use the existing MPO channel polarity design guide.

Compare neighboring requirements

Your requirementSelection action
Eight OS2 fibers ending in eight FC/UPC portsReview this configuration and its port map
Twelve OS2 fibers ending in FCRequest the twelve-fiber configuration; do not substitute an eight-fiber assembly
OM3 or OM4 equipment path ending in FCReview the appropriate multimode configuration
LC equipment portsSelect the applicable LC breakout product
Polarization-maintaining operationRequest a separately specified PM assembly; OS2 alone does not establish PM performance

For the broader assembly options, see the existing MPO/MTP fanout range. Family specifications must not be treated as this SKU’s acceptance limits.

Applications

  • Connecting an eight-fiber singlemode MPO path to an FC/UPC equipment-port schedule, after interface and routing approval.
  • Organizing individual FC connections at a test or instrument panel where the device documentation specifies compatible singlemode interfaces.
  • Replacing an existing FC fanout when the replacement drawing, branch reach and port labels match the installation.

These are candidate uses, not customer case studies or verified equipment endorsements. A passive cable does not establish a data rate or enable a transceiver breakout mode. For any DR4 or other parallel-optics request, check the exact equipment model, optical interface and operating mode; this FC-terminated assembly cannot directly plug into an LC port.

Order Guide

Send one complete configuration request

Include the equipment model, mating-port drawing, eight-row fiber map, total length and tolerance, branch lengths, jacket requirement, quantity, destination and requested delivery date. Ask for commercial confirmation of MOQ, lead time, sample availability and final part number.

The source’s proposed code is BWN-BO-M8APCF-8FCUPC-OS2-YEL-{POL}-{JKT}-{LEN}. Code syntax and available combinations are confirmation with BWNFiber; it is not a released stock code.

Specify dimensions without ambiguity

State whether total length includes the fanout, where the reference planes lie and whether branches are equal or staggered. Measure required reach to the actual FC ports. Keep meters as the ordering unit; any feet values are approximate references.

LengthApproximate feet
1 m3.28 ft
1.5 m4.92 ft
2 m6.56 ft
3 m9.84 ft
5 m16.40 ft
7 m22.97 ft
10 m32.81 ft
15 m49.21 ft
20 m65.62 ft
25 m82.02 ft
30 m98.43 ft
40 m131.23 ft
50 m164.04 ft

Listed lengths reproduce the source’s requested range, subject to confirmation. They are not a stock or delivery promise.

Why Source from BWNFiber

Agree the acceptance record before purchase

For this proposed configuration, ask BWNFiber to confirm the drawing revision, component identifiers, eight-path continuity map and branch labels before accepting a quotation. Request the applicable fiber optic testing plan, including insertion loss and return loss criteria, test wavelengths, reference conditions and traceable record identifiers. Record availability and actual fiber optic manufacturing controls are confirmation with BWNFiber.

IEC 61754-13 addresses the FC-PC connector interface. IEC TR 61282-15 provides guidance for testing MPO-terminated multifiber cabling. These references help frame the engineering review; they do not certify this BWNFiber assembly. The source’s IEC/TIA and RoHS claims require applicable editions and supporting documents before publication as conformity statements.

Confirm customization and installation requirements

Submit requested branch staggering, labels, jacket, packaging and lengths for feasibility review. Do not assume all combinations are available. For North American installations, obtain evidence for any specified plenum or riser rating. For European projects, state the required reaction-to-fire documentation where applicable. An LSZH material description alone does not establish either requirement.

Need a Configuration Review or Sample?

Send your MPO port drawing and eight FC destinations with lengths, jacket requirement and quantity. Request a configuration review and quotation and ask which drawing, sample and test records can be supplied for approval. Commercial terms and documentation remain confirmation with BWNFiber.

FAQ

MPO 8 Fiber OS2 to FC Breakout Cable FAQ

Does eight fiber mean eight duplex FC connections?

No. The supplied configuration has eight simplex FC terminations. Any transmit/receive pairing must be assigned by the equipment port schedule.

Can I select this cable from the MPO-8 name alone?

No. Confirm the physical MPO interface, occupied positions, pin state, key orientation and complete fiber map.

Why are APC and UPC both listed?

They describe different connector ends: MPO/APC and FC/UPC. Match the mating interface at each end separately.

Is this an FC/APC product?

No. The supplied branch configuration is FC/UPC. An FC/APC requirement needs a separate specification and feasibility review.

Can it replace a twelve-fiber OS2 FC harness?

Not as a like-for-like replacement. It provides eight active fibers; review the required number of paths and connector layout.

Is this the same as the OM3 FC version?

No. The proposed fiber is OS2 singlemode. Confirm the fiber requirement across the entire optical path before selecting a multimode alternative.

Does Type B specify all FC port assignments?

No. Supply or request the eight-path map with a stated connector viewing orientation and branch labels.

Is the cable automatically compatible with DR4?

No compatibility is established by this description. Verify the specific module interface and host mode. FC branches do not directly mate with LC ports.

What length should I put on the RFQ?

Provide total and branch lengths, tolerances and reference points. The supplied 1–50 m range is subject to BWNFiber confirmation.

Can I treat LSZH as a plenum rating?

No. Request the precise jacket requirement and corresponding documentation. Availability and conformity are confirmation with BWNFiber.

What optical report should I request?

Ask for branch-identified continuity and applicable IL/RL results with limits, wavelengths and reference method. Actual test scope is confirmation with BWNFiber.

Is this a polarization-maintaining fanout?

PM performance is not specified in the source. If required, submit a separate PM specification rather than assuming that OS2 provides it.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.