MPO 8F OS2 low loss LC simplex breakout cable
Secondary Keywords
8 fiber MPO APC female to LC UPC harness; OS2 eight individual LC fanout; low loss singlemode simplex harness
H1
MPO 8F OS2 Low-Loss to LC Simplex Breakout Cable
Hero
One MPO/APC female interface to eight individual LC/UPC connectors on OS2 fiber. Define the fiber mapping and optical acceptance limits with your configuration request.
Product Overview
This MPO 8F OS2 low-loss LC simplex breakout cable is specified in the supplied product sheet with one MPO/APC female end and eight individual LC/UPC branches. The proposed assembly uses eight active single-mode fibers and a yellow jacket. It is intended for projects requiring separately identified LC terminations, subject to approval of the mating interfaces and end-to-end fiber map.
Eight LC simplex connectors describe eight individual fiber terminations. They do not establish eight duplex links or a transceiver breakout mode. Before choosing this assembly, compare the required connector grouping with the physical LC ports and the approved channel assignment.
For other fiber counts and connector formats, browse the MPO breakout and harness cable range. Broader system selection belongs in MPO cabling; this page addresses one proposed eight-fiber configuration.
Key Features
- Eight active OS2 single-mode fibers with individual LC/UPC terminations, as described in the supplied sheet.
- MPO/APC female interface; ferrule position layout and mating pin state must be checked on the approved drawing.
- Low-loss MPO grade requested as part of the order; numerical limits and measurement conditions must be agreed before acceptance.
- Factory-defined mapping rather than field-switchable polarity.
- Length, fanout and jacket selections recorded together on one configuration sheet.
Technical Specifications
The following values come from the supplied product description. They are proposed configuration details, not independently verified production or compliance claims.
| Parameter | Supplied configuration | Release requirement |
|---|---|---|
| Fiber count | 8 active fibers | confirmation with BWNFiber: BOM and occupied ferrule positions |
| MPO termination | MPO-8/APC female | confirmation with BWNFiber: interface drawing, key orientation and pin state |
| Branch termination | 8 × LC/UPC, individual simplex connectors | confirmation with BWNFiber: branch labels and construction |
| Fiber | OS2, 9/125 μm | confirmation with BWNFiber: exact fiber specification; no G.657 subtype inferred |
| Jacket color | Yellow | confirmation with BWNFiber: production color |
| Loss grade | Low loss at the MPO end | confirmation with BWNFiber: maximum IL, minimum RL, wavelengths and reference method |
| Overall length | Source lists 1–50 m and custom requests | confirmation with BWNFiber: offered lengths, tolerance and measurement datum |
| Fanout length | Source lists 30 / 45 / 60 cm | confirmation with BWNFiber: equal or staggered legs and breakout-point datum |
| Jacket options | Source lists LSZH, OFNP and OFNR | confirmation with BWNFiber: available constructions and applicable compliance evidence |
| Polarity | Source lists Type A / B / C | confirmation with BWNFiber: full position-to-branch map for the selected construction |
| Bend radius and tensile limits | Not supplied | confirmation with BWNFiber: installation and service limits |
| Standards and declarations | Listed in the source, without supporting reports | confirmation with BWNFiber: current applicability, reports and declarations |
A low-loss label alone is not an acceptance threshold. Specify the MPO interface loss, LC interface loss and complete assembly measurement boundary separately. Record the test wavelengths, reference setup and serial or batch association so results can be compared on the same basis.
Selection Guidance
Match the termination format
| Requirement | Selection direction | Check before ordering |
|---|---|---|
| Eight independently identified LC terminations | Review this proposed simplex assembly | Port labels, branch reach and occupied MPO positions |
| Four paired LC connections | Review a duplex harness configuration | Duplex grouping and transmit/receive map; do not assume clips are interchangeable |
| A fixed Type A order | Treat Type A as an option of the agreed product owner | Resolve the overlap between references 42 and 43 |
| Different connector family or active fiber count | Return to the product range | Confirm a matching configuration rather than adapting this SKU description |
Verify the mating and mapping drawing
Request a drawing that shows the MPO mating face, key orientation, occupied positions and the LC branch label reached by each position. The source term “MPO-8” does not replace a dimensional interface drawing. A Type A, B or C label alone does not show how this particular fanout is labeled or how the complete channel is connected.
For the complete channel, use the MPO polarity checklist and return to this product record only for the assembly-specific drawing.
Check APC and UPC at each mating interface. The different finishes at opposite ends of an assembly do not mean APC and UPC connector faces should be mated together.
Confirm the optical requirement
State the allowable assembly loss and how it fits the complete channel budget. Do not select an assembly merely because another supplier describes a similar item as “Elite.” The supplied material does not establish a branded connector grade or provide measured loss data for this product.
Check installation dimensions
Specify overall length in meters, required fanout reach and connector clearance. Ask BWNFiber to confirm whether the length datum includes connector bodies and where the fanout length begins. For US drawings, 1 m is approximately 3.28 ft and 5 m is approximately 16.40 ft; metric dimensions should remain the controlling values unless the approved drawing states otherwise.
Applications
| Proposed use | Required project evidence | Stop condition |
|---|---|---|
| OS2 panel termination with individually routed LC branches | Panel port list, approved mapping and route dimensions | Branch grouping or length does not match the panel |
| Replacement of an existing eight-fiber harness | Existing assembly drawing, connector identity and acceptance limits | Part name matches but mapping or pin state differs |
| Project-specific equipment cabling | Exact equipment interface and operating mode documentation | Compatibility is inferred only from speed, OS2 or fiber count |
These are selection scenarios, not BWNFiber customer case studies. No 40G, 100G, 400G or 800G compatibility is claimed for this assembly without the exact equipment and channel specification. See data center solutions when evaluating the wider connection architecture.
Order Guide
Prepare one configuration record
- Record the requested product reference and the actual termination format: eight separate LC connectors.
- Attach the MPO-to-LC position map, mating connector information and branch labels.
- State overall length, fanout dimensions, tolerances and the controlling measurement units.
- Identify the jacket requirement and destination installation environment.
- State optical acceptance limits, test wavelengths and required report traceability.
- Add quantity, destination and requested delivery date for quotation review.
| RFQ field | Buyer input | Supplier confirmation |
|---|---|---|
| Interface and map | Drawing revision and port schedule | Matching BOM and mapping drawing |
| Optical acceptance | Maximum IL / minimum RL with measurement boundary | Proposed test method and report availability |
| Mechanical routing | Length, leg reach, clearance and environment | Available construction and installation limits |
| Jacket | Required listing or project specification | Applicable evidence for the selected cable |
| Commercial request | Quantity, destination, requested date | Price, MOQ, lead time and sample availability |
The original sheet repeats the same product name for every polarity × length × jacket combination. This consolidated order record retains the selection dimensions without implying that every combination is available. Type A / B / C availability, the 1–50 m range, custom lengths and the stated fanout options remain confirmation with BWNFiber. The source’s 30 cm default is not an automatic order instruction.
Why Source from BWNFiber
Configuration and customization review
Send the required drawing and project constraints to BWNFiber for a configuration review. Custom lengths, leg layouts, labels, packaging and jacket choices are requests until confirmed in the quotation and approved product documentation. MOQ, delivery time, sample supply and production capacity are confirmation with BWNFiber.
Quality control and testing documentation
Ask for the applicable product datasheet, approved fiber mapping drawing, inspection criteria and available optical test report before placing an order. Useful acceptance records identify the assembly, measured paths, wavelengths, IL/RL limits, results and disposition. Report availability and the actual BWNFiber inspection process are confirmation with BWNFiber.
The source lists TIA/EIA-568.3-D, IEC 61754-7, IEC 61754-20, IEC 61753-1, RoHS and IEC 61300-3-4. This list does not prove conformity, certification or testing. Applicable editions, scope and supporting documents are confirmation with BWNFiber; no compliance claim is made in this draft.
Need a Configuration Review or Sample?
Send BWNFiber your eight-branch port map, mating interface details, overall and fanout lengths, optical acceptance limits, jacket requirement, quantity and destination. Request confirmation of the offered construction, drawing revision and quotation. Sample availability and test documentation should be confirmed with the order review.
Use the existing inquiry form below for the final approved page. This offline preview does not submit inquiries.