Product Overview
This 8F OS2 G.657.A2 MPO to LC simplex breakout cable is specified in the supplied product brief with one female MPO/APC end, eight individual LC/UPC ends, a black LSZH jacket and fixed Type A wiring. It is intended for a defined single-mode port map where each LC branch needs separate identification. Confirm the assembly drawing before ordering.
The black jacket is part of this configuration’s requested identity. It does not identify optical performance or approve the cable for a particular installation environment. Check the fiber designation on the build sheet and cable marking rather than relying on jacket color.
This configuration uses eight simplex terminations. It is not automatically a four-channel transceiver breakout: pairing, populated MPO positions and the equipment lane map must agree. A matching connector housing alone is insufficient to approve a link.
Key Features
- Eight active single-mode fibers with individual LC branch identification.
- MPO/APC female interface at one end and eight LC/UPC simplex connectors at the other.
- OS2 cabling designation with G.657.A2 fiber specified separately.
- Black LSZH jacket and fixed Type A wiring in the source configuration.
- Length selection tied to a drawing that defines the trunk, breakout point and branch reach.
Technical Specifications
Review status: The following configuration comes from the supplied brief. Model-specific datasheet, BOM and drawing approval: confirmation with BWNFiber. These entries are not independently verified test results.
| Item | Source configuration / confirmation required |
|---|---|
| Active fiber count | 8 |
| MPO end | Source label: MPO-8/APC female; ferrule format, occupied positions, key orientation and connector part number need drawing confirmation |
| Branch end | 8 × LC/UPC simplex; branch IDs and numbering direction need confirmation |
| Cabling / fiber | OS2 / ITU-T G.657.A2; exact fiber declaration and traceability need confirmation |
| Jacket | Black LSZH; material evidence and applicable installation rating need confirmation |
| Wiring | Fixed Type A as named in the brief; complete MPO-position-to-LC-ID map required |
| Overall length | Source-listed 1–50 m; measurement endpoints, tolerance and order availability need confirmation |
| Fanout length | Source lists 30 / 45 / 60 cm; approved construction and measurement datum need confirmation |
| Cable and branch diameter | confirmation with BWNFiber; no 3.0 mm trunk diameter is assigned to this configuration |
| Insertion loss / return loss | confirmation with BWNFiber for each interface, test wavelength, method and acceptance limit |
| Bend radius / temperature / pulling load | confirmation with BWNFiber for the finished assembly |
| Standards / declarations | Applicable editions, scope and model-specific evidence: confirmation with BWNFiber |
Optical acceptance information
Request an acceptance sheet that identifies the assembly revision, each of the eight branches, test wavelengths, reference method and agreed loss limits. Keep MPO and LC interface requirements separate from the total channel budget. A family-level loss table is not evidence that this black-jacket configuration meets the same limits.
A polarity record should show populated MPO positions, the viewing direction, key orientation and the LC identifier at the other end. Do not release a drawing containing only “Type A” without its connection map. The availability of per-branch records, inspection images and shipment documentation is confirmation with BWNFiber.
Selection Guidance
Check the mating interfaces
Use a mating MPO interface with the specified compatible end face, alignment-pin arrangement and keying. Female generally identifies an unpinned connector; the exact supplied connector must be checked against its part number. The LC/UPC ends must meet compatible LC/UPC interfaces. Different polishes on opposite ends of this cable are not the same as mating APC and UPC faces at one connection.
Check routing and jacket requirements
G.657.A2 describes bending-loss performance of the fiber. It does not provide the installation bend radius of the jacketed trunk, breakout body or protected legs. Ask for static and installation limits for the completed assembly, and keep the breakout body clear of the tightest bend. ITU-T G.657 reference.
For a US project, give the installation location and required cable rating to the responsible project reviewer. LSZH alone does not establish an OFNP or OFNR rating. A replacement jacket requires an approved alternative build; it is not a selectable version of the same black LSZH item by default.
For the underlying designation distinction, see the OS2 and fiber specification reference.
Check whether this exact configuration is necessary
| Requirement | Decision |
|---|---|
| Eight separate LC terminations, black LSZH and specified G.657.A2 fiber | Review this configuration against the drawing |
| Yellow jacket with a specified trunk diameter | Compare the separately defined standard configuration; do not substitute silently |
| A guaranteed low-loss grade | Request its numerical limits and evidence; this item has no approved low-loss claim |
| LC duplex clips or uniboot terminations | Select another branch construction through the category |
| Twelve active fibers | Select a separate 12F configuration; this item has eight |
For a complete channel, use the MPO polarity design workflow. To compare other branch constructions, return to the breakout and harness product range.
Applications
- Single-mode panel-to-port routing with eight individually managed LC connections, where the approved port map matches this assembly.
- Rack or tray layouts specifying G.657.A2 fiber and black cable identification, subject to finished-cable bend and fire-rating approval.
- Replacement of an existing harness when connector BOM, position map, branch reach and optical requirements match the original controlled drawing.
These are selection scenarios, not verified BWNFiber customer projects. No Ethernet speed, transceiver family or transmission distance is approved from the 8F designation alone.
Order Guide
Use one configuration description: 8F OS2 G.657.A2, MPO/APC female to 8 × LC/UPC simplex, black LSZH, Type A. Select length against the approved drawing. All source-listed lengths below require availability confirmation; they are not stock promises. Metric dimensions govern; feet are rounded to two decimals.
| Overall length (m) | Approximate length (ft) |
|---|---|
| 1 | 3.28 |
| 1.5 | 4.92 |
| 2 | 6.56 |
| 3 | 9.84 |
| 5 | 16.40 |
| 7 | 22.97 |
| 10 | 32.81 |
| 15 | 49.21 |
| 20 | 65.62 |
| 25 | 82.02 |
| 30 | 98.43 |
| 40 | 131.23 |
| 50 | 164.04 |
Information to include with the request
- Equipment and panel part numbers, plus the existing channel drawing if available.
- Populated MPO positions, key orientation, pin state and LC branch IDs.
- Overall length, breakout-point location, each branch length and measurement tolerance.
- Black LSZH requirement, destination market and required installation rating.
- Acceptance limits, quantity, destination, target delivery date and labeling needs.
Custom lengths, staggered legs, 0.9 mm branch construction, pulling protection, OEM printing and alternative jackets: confirmation with BWNFiber. MOQ, pricing, sample availability and lead time require a quotation. The code BWN-BO-M8APCF-8LCSX-OS2-G657A2-BLK-LSZH-A-{LEN} is a proposed internal pattern from the brief, not a verified orderable part number.
Why Source from BWNFiber
Use the configuration request to resolve one build: the same description should appear on the quotation, approved drawing, cable identification and acceptance record. Ask BWNFiber to identify any proposed substitution before the order is accepted. Manufacturing capability, inspection scope and supporting records for this specific item remain confirmation with BWNFiber.
The existing harness family overview can help locate other connector combinations. A family listing does not replace this item’s approved specification.
Need a Configuration Review or Sample?
Send the eight-branch connection map, requested length, black-jacket requirement and quantity to BWNFiber. Request a configuration review, applicable datasheet and written quotation. Include the required delivery date so sample and production feasibility can be assessed.
CTA: Request an 8-Branch Configuration Review.