MPO Breakout & Harness Cable

MPO 8 Fiber OM4 to LC Simplex Breakout Cable

Eight simplex connectors describe eight physical terminations. They do not establish eight independent Ethernet channels, nor do they confirm a particular transceiver breakout mode. The active fiber positions, equipment interfaces and approved wiring map determine the connection. For other branch formats, compare the MPO breakout and harness cable range.

MPO Breakout & Harness Cable

Hero

Connect an eight-fiber OM4 assembly to eight individually handled LC/UPC ends. This MPO-to-LC simplex configuration is intended for separate LC adapter positions where each fiber needs its own identified termination. Confirm the MPO interface drawing and branch map before selecting a cable length or approving a purchase order.

Product Overview

The MPO 8 fiber OM4 to LC simplex breakout cable is specified in the supplied product record with a female MPO/PC end, eight LC/UPC simplex connectors and a violet jacket. Its distinguishing feature is the separate LC connector format, which supports individual fiber routing at a compatible panel or test interface.

Eight simplex connectors describe eight physical terminations. They do not establish eight independent Ethernet channels, nor do they confirm a particular transceiver breakout mode. The active fiber positions, equipment interfaces and approved wiring map determine the connection. For other branch formats, compare the MPO breakout and harness cable range.

Key Features

  • Eight active fibers, with OM4 50/125 μm multimode fiber specified in the source record.
  • One female MPO/PC end and eight separate LC/UPC ends.
  • Violet jacket identification; verify the actual cable marking and drawing.
  • Individual branch handling for separately positioned LC adapters.
  • Configuration defined by a connector-to-branch map, length drawing and acceptance requirements.

Technical Specifications

The following values describe the submitted configuration. The released datasheet and quotation must confirm the final build.

ParameterSubmitted configuration / purchase check
Product familyMPO breakout / harness cable
Active fiber count8
FiberOM4 multimode, 50/125 μm
MPO endSource designation MPO-8/PC, female; confirm ferrule format, populated positions and key orientation
Branch end8 × LC/UPC simplex connectors
Jacket colorViolet
Overall length choicesSource lists 1–50 m; exact available combinations require confirmation
Fanout lengthSource lists 30, 45 or 60 cm; define the measurement datum and branch tolerance on the drawing
Jacket requirementsLSZH, OFNP or OFNR requested by project; confirm cable construction and supporting documentation
Polarity / fiber mapSpecify MPO cavity position → LC branch ID; approve the drawing rather than choosing from a label alone
Optical acceptanceInsertion loss, return loss, wavelengths and reference method to be agreed; no approved numeric limits supplied
Mechanical acceptanceCable diameter, leg diameter, bend radius, pull limits and temperature range require a released datasheet

Selection Guidance

Confirm the mating interface

Record the panel or equipment part number. Confirm guide-pin arrangement, key orientation and end-face finish at each connection. The source calls the MPO end female; do not infer pinning of the mating component from the cable name alone.

Approve eight identifiable fiber paths

Ask for a drawing with eight branch IDs, each linked to a populated MPO cavity. If a 12-position ferrule is used with eight active fibers, the drawing must identify the unused positions. Do not assign LC branch 1 to MPO position 1 without that evidence. A Type A, B or C selection is insufficient on its own to approve a complete channel.

For a complete system rather than a single assembly, use the MPO channel polarity design workflow.

Match the connector format to the destination

Destination requirementSelection implication
Eight separate LC adapter positionsReview this simplex format and branch labeling
Four pre-paired LC duplex connectionsRequest a duplex configuration; do not assume clips, pairing or a wiring conversion are included
A cassette or different active fiber countConfirm the cassette drawing and select a matching assembly
A transceiver operating in breakout modeConfirm the exact module, supported mode, lane pairing and link budget separately

Set length and routing requirements

Measure the installed route and service allowance, then specify overall length and individual fanout lengths separately. Show the reference points on the drawing. A 50 m assembly option does not establish a 50 m supported transmission reach for every optical application. Avoid pulling on connector boots or loading unsupported branch legs; obtain the cable-specific installation limits.

Applications

  • Individually numbered LC panel positions in an OM4 cabling system, after interface and mapping review.
  • Test-fixture connections that require separate access to eight terminated fibers, subject to fixture compatibility.
  • Rack or cabinet routing where LC terminations land at different positions and branch lengths need to be specified individually.

These are selection scenarios, not claims of completed BWNFiber projects or universal equipment compatibility. This SKU does not claim 40G, 100G or 400G breakout support merely from its connector count.

Order Guide

Define one build record

Send the MPO mating interface, eight-branch connection schedule, route dimensions, jacket requirement, quantity and destination. Ask BWNFiber to confirm feasible options and a controlled drawing before the order is released.

Order fieldWhat to send
IdentityMPO PC female to 8 LC UPC simplex; 8 active OM4 fibers; violet
MappingEach MPO position, LC branch ID and destination port
Overall lengthOne metric length, defined measurement points and tolerance
FanoutEqual or staggered lengths; measured from the breakout point as agreed
JacketRequired construction and project documentation, not color alone
AcceptanceOptical limits, reference method, branch continuity and labeling record
CommercialQuantity, destination, required date, sample and packaging request

Source-listed length choices

The source lists 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m. These are quotation inputs; current availability requires confirmation.

MetresApproximate feetMetresApproximate feet
13.281.54.92
26.5639.84
516.40722.97
1032.811549.21
2065.622582.02
3098.4340131.23
50164.04——

Metric dimensions control the order. Rounded imperial equivalents are for reference.

Custom requests

The source mentions alternative fanout dimensions, 0.9 mm legs, pulling eyes and identification options. Submit these as requests for feasibility review; they are not confirmed options for every length or jacket. Ask for a part number only after the final configuration is approved. The suggested source order-code pattern is not a validated BWNFiber ordering code.

Why Source from BWNFiber

Use the inquiry to establish a documented configuration rather than relying on a broad family description. Ask BWNFiber for the exact assembly drawing, the agreed bill of materials and the inspection records available for this build.

Quality control and acceptance documents

Request end-face inspection criteria, continuity and branch mapping results, and insertion-loss records identifying each tested fiber. Agree the return-loss requirement where applicable, wavelengths, test reference and pass/fail limits before acceptance. General fiber optic cable testing guidance explains the wider test context; it does not certify this SKU.

A standards list is not evidence that a specific assembly passed testing. Ask for the applicable document, revision and product scope for every compliance claim. Confirm lead time, MOQ, sample availability, labeling and packing in the quotation.

Need a Configuration Review or Sample?

Send your eight-port LC schedule, MPO interface drawing, overall and branch lengths, jacket requirement, quantity and destination. Request a configuration review and quote for the OM4 simplex assembly. Include any test-record or sample requirements so that the quotation can address them explicitly.

FAQ

MPO 8 Fiber OM4 to LC Simplex Breakout Cable FAQ

Does this cable have eight LC simplex ends or four duplex ends?

The supplied configuration specifies eight separate LC/UPC simplex ends. If your design requires pre-paired duplex connectors, request the corresponding assembly and drawing.

Does eight active fibers mean the MPO has only eight positions?

Not necessarily. Active fiber count and ferrule format are separate fields. Confirm the physical interface and populated cavities on the approved drawing.

Does this assembly provide eight Ethernet channels?

Connector count alone cannot establish channel count. Identify the equipment transmit/receive paths and the required pairing before making a channel claim.

Can this SKU be specified as an SR4 breakout?

Only after checking the exact equipment mode and lane map. The simplex format neither proves nor categorically prevents that use; this product page does not claim SR4 compatibility.

Which polarity should I order?

Send the required MPO-position-to-LC-branch schedule. Have the final drawing confirmed rather than selecting Type A, B or C without the channel context.

Can polarity be changed in the field?

The supplied record describes a fixed configuration. Do not plan on field changes; obtain confirmation of the ordered wiring map.

Is the 30 cm fanout a guaranteed default?

The source lists that default, but no released drawing was supplied. Put the required fanout dimension and tolerance explicitly on the quotation and drawing.

Does a violet jacket prove the fiber grade or fire rating?

No. Confirm the fiber specification and cable marking. Color does not replace construction records or the documentation required for the installation.

Are LSZH, OFNP and OFNR interchangeable choices?

Do not treat them as equivalent approvals. State the installation requirements and obtain documentation for the exact proposed cable construction.

Are loss limits or certificates included in this page?

No approved SKU-specific numeric limits or certificates were provided. Request the agreed acceptance specification and the evidence applicable to the proposed build.

Is a custom order code already available?

The source contains a suggested pattern only. Ask BWNFiber to assign or confirm the final part number against the approved configuration.

What is the minimum information for a useful quotation?

Provide the eight LC destinations, MPO interface, wiring map, dimensions, jacket requirement, quantity and destination, plus any required delivery date or acceptance documents.

| — | — | — |

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.