Connect an eight-fiber OM4 assembly to eight individually handled LC/UPC ends. This MPO-to-LC simplex configuration is intended for separate LC adapter positions where each fiber needs its own identified termination. Confirm the MPO interface drawing and branch map before selecting a cable length or approving a purchase order.
Product Overview
The MPO 8 fiber OM4 to LC simplex breakout cable is specified in the supplied product record with a female MPO/PC end, eight LC/UPC simplex connectors and a violet jacket. Its distinguishing feature is the separate LC connector format, which supports individual fiber routing at a compatible panel or test interface.
Eight simplex connectors describe eight physical terminations. They do not establish eight independent Ethernet channels, nor do they confirm a particular transceiver breakout mode. The active fiber positions, equipment interfaces and approved wiring map determine the connection. For other branch formats, compare the MPO breakout and harness cable range.
Key Features
- Eight active fibers, with OM4 50/125 μm multimode fiber specified in the source record.
- One female MPO/PC end and eight separate LC/UPC ends.
- Violet jacket identification; verify the actual cable marking and drawing.
- Individual branch handling for separately positioned LC adapters.
- Configuration defined by a connector-to-branch map, length drawing and acceptance requirements.
Technical Specifications
The following values describe the submitted configuration. The released datasheet and quotation must confirm the final build.
| Parameter | Submitted configuration / purchase check |
|---|---|
| Product family | MPO breakout / harness cable |
| Active fiber count | 8 |
| Fiber | OM4 multimode, 50/125 μm |
| MPO end | Source designation MPO-8/PC, female; confirm ferrule format, populated positions and key orientation |
| Branch end | 8 × LC/UPC simplex connectors |
| Jacket color | Violet |
| Overall length choices | Source lists 1–50 m; exact available combinations require confirmation |
| Fanout length | Source lists 30, 45 or 60 cm; define the measurement datum and branch tolerance on the drawing |
| Jacket requirements | LSZH, OFNP or OFNR requested by project; confirm cable construction and supporting documentation |
| Polarity / fiber map | Specify MPO cavity position → LC branch ID; approve the drawing rather than choosing from a label alone |
| Optical acceptance | Insertion loss, return loss, wavelengths and reference method to be agreed; no approved numeric limits supplied |
| Mechanical acceptance | Cable diameter, leg diameter, bend radius, pull limits and temperature range require a released datasheet |
Selection Guidance
Confirm the mating interface
Record the panel or equipment part number. Confirm guide-pin arrangement, key orientation and end-face finish at each connection. The source calls the MPO end female; do not infer pinning of the mating component from the cable name alone.
Approve eight identifiable fiber paths
Ask for a drawing with eight branch IDs, each linked to a populated MPO cavity. If a 12-position ferrule is used with eight active fibers, the drawing must identify the unused positions. Do not assign LC branch 1 to MPO position 1 without that evidence. A Type A, B or C selection is insufficient on its own to approve a complete channel.
For a complete system rather than a single assembly, use the MPO channel polarity design workflow.
Match the connector format to the destination
| Destination requirement | Selection implication |
|---|---|
| Eight separate LC adapter positions | Review this simplex format and branch labeling |
| Four pre-paired LC duplex connections | Request a duplex configuration; do not assume clips, pairing or a wiring conversion are included |
| A cassette or different active fiber count | Confirm the cassette drawing and select a matching assembly |
| A transceiver operating in breakout mode | Confirm the exact module, supported mode, lane pairing and link budget separately |
Set length and routing requirements
Measure the installed route and service allowance, then specify overall length and individual fanout lengths separately. Show the reference points on the drawing. A 50 m assembly option does not establish a 50 m supported transmission reach for every optical application. Avoid pulling on connector boots or loading unsupported branch legs; obtain the cable-specific installation limits.
Applications
- Individually numbered LC panel positions in an OM4 cabling system, after interface and mapping review.
- Test-fixture connections that require separate access to eight terminated fibers, subject to fixture compatibility.
- Rack or cabinet routing where LC terminations land at different positions and branch lengths need to be specified individually.
These are selection scenarios, not claims of completed BWNFiber projects or universal equipment compatibility. This SKU does not claim 40G, 100G or 400G breakout support merely from its connector count.
Order Guide
Define one build record
Send the MPO mating interface, eight-branch connection schedule, route dimensions, jacket requirement, quantity and destination. Ask BWNFiber to confirm feasible options and a controlled drawing before the order is released.
| Order field | What to send |
|---|---|
| Identity | MPO PC female to 8 LC UPC simplex; 8 active OM4 fibers; violet |
| Mapping | Each MPO position, LC branch ID and destination port |
| Overall length | One metric length, defined measurement points and tolerance |
| Fanout | Equal or staggered lengths; measured from the breakout point as agreed |
| Jacket | Required construction and project documentation, not color alone |
| Acceptance | Optical limits, reference method, branch continuity and labeling record |
| Commercial | Quantity, destination, required date, sample and packaging request |
Source-listed length choices
The source lists 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m. These are quotation inputs; current availability requires confirmation.
| Metres | Approximate feet | Metres | Approximate feet |
|---|---|---|---|
| 1 | 3.28 | 1.5 | 4.92 |
| 2 | 6.56 | 3 | 9.84 |
| 5 | 16.40 | 7 | 22.97 |
| 10 | 32.81 | 15 | 49.21 |
| 20 | 65.62 | 25 | 82.02 |
| 30 | 98.43 | 40 | 131.23 |
| 50 | 164.04 | — | — |
Metric dimensions control the order. Rounded imperial equivalents are for reference.
Custom requests
The source mentions alternative fanout dimensions, 0.9 mm legs, pulling eyes and identification options. Submit these as requests for feasibility review; they are not confirmed options for every length or jacket. Ask for a part number only after the final configuration is approved. The suggested source order-code pattern is not a validated BWNFiber ordering code.
Why Source from BWNFiber
Use the inquiry to establish a documented configuration rather than relying on a broad family description. Ask BWNFiber for the exact assembly drawing, the agreed bill of materials and the inspection records available for this build.
Quality control and acceptance documents
Request end-face inspection criteria, continuity and branch mapping results, and insertion-loss records identifying each tested fiber. Agree the return-loss requirement where applicable, wavelengths, test reference and pass/fail limits before acceptance. General fiber optic cable testing guidance explains the wider test context; it does not certify this SKU.
A standards list is not evidence that a specific assembly passed testing. Ask for the applicable document, revision and product scope for every compliance claim. Confirm lead time, MOQ, sample availability, labeling and packing in the quotation.
Need a Configuration Review or Sample?
Send your eight-port LC schedule, MPO interface drawing, overall and branch lengths, jacket requirement, quantity and destination. Request a configuration review and quote for the OM4 simplex assembly. Include any test-record or sample requirements so that the quotation can address them explicitly.