Product Overview
The supplied configuration combines one MPO-8/PC female connector with four SC/UPC duplex connectors, OM3 50/125 μm fiber and an aqua jacket. It provides a defined transition from an MPO interface to separate SC connection points. It is a passive cable assembly: it does not convert protocols, change fiber type or guarantee a transmission speed.
Choose this item when the receiving patch panel requires SC/UPC duplex connections. For other branch interfaces, start with the MPO breakout and harness selection page. The exact MPO ferrule format, eight populated positions and connector end views are confirmation with BWNFiber before the configuration is released.
Key Features
- Eight source-specified OM3 multimode fiber paths, grouped into four SC duplex pairs.
- MPO PC female / unpinned connector at the common end; SC/UPC at the branches.
- Source-designated Type B build, subject to approval of the actual position-to-branch map.
- Aqua jacket for the supplied configuration; color is not evidence of optical performance.
- Metric length selection and branch-reach planning recorded in one order schedule.
- Fixed product identity: a different fiber grade, branch connector or polarity requires a separately reviewed configuration.
Technical Specifications
Specification notice: Values identified as source-listed come from the supplied product document. They are not a signed manufacturing specification. Confirm the final drawing, available combinations and acceptance requirements with BWNFiber.
| Parameter | Supplied configuration / release requirement |
|---|---|
| Document reference | 30; a document number, not a verified manufacturer part number |
| Fiber paths | 8 active fibers |
| Fiber | OM3 multimode, 50/125 μm |
| Common connector | MPO-8/PC female; exact ferrule format and populated positions: confirmation with BWNFiber |
| Branch connectors | 4 × SC/UPC duplex; eight individual SC terminations |
| Polarity | Type B in source; approve mapping, viewing direction, key orientation and pair labels |
| Jacket color | Aqua in source |
| Overall lengths | 1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m, source-listed |
| Length tolerance and measurement points | confirmation with BWNFiber |
| Fanout length | 30 / 45 / 60 cm in source; measurement points, arrangement and availability: confirmation with BWNFiber |
| Jacket requests | LSZH / OFNP / OFNR listed; exact construction and supporting documents: confirmation with BWNFiber |
| Optical acceptance | Maximum insertion loss, minimum return loss, test wavelength and reference method: confirmation with BWNFiber |
| Handling limits | Bend radius, branch diameter, tensile limits and operating temperature: confirmation with BWNFiber |
| Compliance | Exact standards editions, applicable clauses, declarations and SKU coverage: confirmation with BWNFiber |
The source cites TIA/EIA-568.3-D, IEC 61754-4, IEC 61754-7, IEC 61753-1, RoHS and IEC 61300-3-4. These references do not establish tested compliance or certification for this assembly. Keep them in the approval record until the applicable edition and product evidence are confirmed.
Selection Guidance
Match the SC panel before selecting the cable length
Record the panel and adapter model, connector polish and spacing between the four duplex ports. Confirm that each branch reaches its intended adapter without crossing another branch or loading the breakout transition. Leave service slack according to the approved handling limits. A nominal 30 cm fanout is not proof that every branch can reach the same panel layout.
Approve each of the eight fiber paths
Ask for a drawing that identifies the MPO viewing direction, key orientation, populated positions, branch numbers and the two SC positions in each duplex pair. Trace each required transmit-to-receive path through the complete installed channel. The words “Type B” on the order line do not specify which SC connector lands at each panel port. Use the channel polarity review workflow for the complete system map.
Drawing approval record
| Required field | Record before order release |
|---|---|
| MPO end view | Connector format, key direction, pin state and numbered populated positions |
| Branch identification | Pair 1–4 and the two connector identifiers within each pair |
| Panel destination | Adapter and port identifier for every SC termination |
| Orientation | Viewing direction for both the connector drawing and panel drawing |
| Revision | Approved drawing revision, approval date and responsible engineer |
This is a blank approval method, not a supplied pinout. Do not manufacture or install from an assumed 1-to-8 reversal.
Check the actual mating interfaces
Verify the mating connector behind the MPO adapter, including pinning and polish. Confirm SC/UPC at the branch destinations; an SC/APC port is a different interface requirement. The four SC pairs are not LC connectors. Any path involving LC equipment needs its own compatible components and channel review; this assembly alone does not establish a direct LC transceiver connection.
Agree what the optical limit covers
Request maximum loss limits with the measurement scope stated: a mated connector pair, one branch path, or the complete assembly. Specify the test wavelength, reference setup and records required for all eight paths. Compare the resulting assembly limit with the allocated channel budget. Factory acceptance and installed-channel acceptance are separate decisions; neither is established by the jacket color or Type B label.
Applications
| Buyer task | Why this item may fit | Approval condition |
|---|---|---|
| Retain an existing SC/UPC duplex patch panel | Four SC pairs connect to separate panel positions | OM3 plant, connector compatibility and approved pair-to-port map |
| Replace a documented MPO-to-SC harness | One order record can preserve the existing connection pattern | Compare original and replacement drawings, branch reach and optical limits |
| Prepare a distributor repeat-order configuration | Fixed connector and fiber identity reduces ambiguous descriptions | Approved configuration identifier, revision, labels and jacket documentation |
These are selection scenarios, not customer case studies. Supported network speed and reach depend on the equipment and the entire channel. They are not claimed for this product from the supplied data.
Order Guide
Keep OM3 fiber, eight active paths, MPO PC female, four SC/UPC duplex pairs and the approved Type B map fixed. Choose the requested overall length and jacket, then specify the branch reach on the drawing.
| Order input | Information to send |
|---|---|
| Identity | Document 30 and the approved assembly drawing revision |
| Overall length | Source-listed metric length; measurement endpoints and tolerance |
| Fanout | Required reach to each of the four SC duplex ports; equal or staggered arrangement for review |
| Jacket | Requested designation plus destination and installation requirements |
| Map | MPO end view, SC pair identifiers and panel port schedule |
| Acceptance | Agreed optical limits, measurement scope, inspection and record requirements |
| Quantity | Quantity per length/jacket combination and sample quantity if required |
| Handover | Label wording, packaging and required approval documents |
The source’s 39 length/jacket rows are retained in a separate review schedule without repeating the full product name in every row. Metric length controls: for example, 1 m ≈ 3.28 ft, 1.5 m ≈ 4.92 ft and 2 m ≈ 6.56 ft. Rounded imperial labels must not be treated as equivalent order lengths. Custom lengths, supported branch arrangements, stock, sample availability, MOQ and lead time are confirmation with BWNFiber.
Why Source from BWNFiber
Ask BWNFiber for a quotation tied to the approved SC panel map and assembly drawing. Keep any exceptions beside the original requirement so purchasing, receiving and repeat orders use the same configuration.
Request the inspection scope, continuity and polarity records, connector end-face acceptance criteria, optical test conditions and documentation included with the shipment. Fiber optic testing coverage and manufacturing traceability for this exact item are confirmation with BWNFiber. The source does not establish a verified certification, test percentage or delivery promise. If the branch connector is still undecided, compare the existing configurable fanout range before specifying this SC assembly.
Need a Configuration Review or Sample?
Request a quote for the SC duplex configuration. Send document 30, the SC panel model, eight-path drawing, overall length, branch reach, jacket, quantity and destination. Ask for the proposed specification, unresolved exceptions and available sample documentation before approving the order.