MPO Breakout & Harness Cable

MPO 8F OM3 to SC Duplex Type B Breakout Cable

The supplied configuration combines one MPO-8/PC female connector with four SC/UPC duplex connectors, OM3 50/125 μm fiber and an aqua jacket. It provides a defined transition from an MPO interface to separate SC connection points. It is a passive cable assembly: it does not convert protocols, change fiber type or guarantee a transmission speed.

MPO Breakout & Harness Cable

Product Overview

The supplied configuration combines one MPO-8/PC female connector with four SC/UPC duplex connectors, OM3 50/125 μm fiber and an aqua jacket. It provides a defined transition from an MPO interface to separate SC connection points. It is a passive cable assembly: it does not convert protocols, change fiber type or guarantee a transmission speed.

Choose this item when the receiving patch panel requires SC/UPC duplex connections. For other branch interfaces, start with the MPO breakout and harness selection page. The exact MPO ferrule format, eight populated positions and connector end views are confirmation with BWNFiber before the configuration is released.

Key Features

  • Eight source-specified OM3 multimode fiber paths, grouped into four SC duplex pairs.
  • MPO PC female / unpinned connector at the common end; SC/UPC at the branches.
  • Source-designated Type B build, subject to approval of the actual position-to-branch map.
  • Aqua jacket for the supplied configuration; color is not evidence of optical performance.
  • Metric length selection and branch-reach planning recorded in one order schedule.
  • Fixed product identity: a different fiber grade, branch connector or polarity requires a separately reviewed configuration.

Technical Specifications

Specification notice: Values identified as source-listed come from the supplied product document. They are not a signed manufacturing specification. Confirm the final drawing, available combinations and acceptance requirements with BWNFiber.

ParameterSupplied configuration / release requirement
Document reference30; a document number, not a verified manufacturer part number
Fiber paths8 active fibers
FiberOM3 multimode, 50/125 μm
Common connectorMPO-8/PC female; exact ferrule format and populated positions: confirmation with BWNFiber
Branch connectors4 × SC/UPC duplex; eight individual SC terminations
PolarityType B in source; approve mapping, viewing direction, key orientation and pair labels
Jacket colorAqua in source
Overall lengths1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m, source-listed
Length tolerance and measurement pointsconfirmation with BWNFiber
Fanout length30 / 45 / 60 cm in source; measurement points, arrangement and availability: confirmation with BWNFiber
Jacket requestsLSZH / OFNP / OFNR listed; exact construction and supporting documents: confirmation with BWNFiber
Optical acceptanceMaximum insertion loss, minimum return loss, test wavelength and reference method: confirmation with BWNFiber
Handling limitsBend radius, branch diameter, tensile limits and operating temperature: confirmation with BWNFiber
ComplianceExact standards editions, applicable clauses, declarations and SKU coverage: confirmation with BWNFiber

The source cites TIA/EIA-568.3-D, IEC 61754-4, IEC 61754-7, IEC 61753-1, RoHS and IEC 61300-3-4. These references do not establish tested compliance or certification for this assembly. Keep them in the approval record until the applicable edition and product evidence are confirmed.

Selection Guidance

Match the SC panel before selecting the cable length

Record the panel and adapter model, connector polish and spacing between the four duplex ports. Confirm that each branch reaches its intended adapter without crossing another branch or loading the breakout transition. Leave service slack according to the approved handling limits. A nominal 30 cm fanout is not proof that every branch can reach the same panel layout.

Approve each of the eight fiber paths

Ask for a drawing that identifies the MPO viewing direction, key orientation, populated positions, branch numbers and the two SC positions in each duplex pair. Trace each required transmit-to-receive path through the complete installed channel. The words “Type B” on the order line do not specify which SC connector lands at each panel port. Use the channel polarity review workflow for the complete system map.

Drawing approval record

Required fieldRecord before order release
MPO end viewConnector format, key direction, pin state and numbered populated positions
Branch identificationPair 1–4 and the two connector identifiers within each pair
Panel destinationAdapter and port identifier for every SC termination
OrientationViewing direction for both the connector drawing and panel drawing
RevisionApproved drawing revision, approval date and responsible engineer

This is a blank approval method, not a supplied pinout. Do not manufacture or install from an assumed 1-to-8 reversal.

Check the actual mating interfaces

Verify the mating connector behind the MPO adapter, including pinning and polish. Confirm SC/UPC at the branch destinations; an SC/APC port is a different interface requirement. The four SC pairs are not LC connectors. Any path involving LC equipment needs its own compatible components and channel review; this assembly alone does not establish a direct LC transceiver connection.

Agree what the optical limit covers

Request maximum loss limits with the measurement scope stated: a mated connector pair, one branch path, or the complete assembly. Specify the test wavelength, reference setup and records required for all eight paths. Compare the resulting assembly limit with the allocated channel budget. Factory acceptance and installed-channel acceptance are separate decisions; neither is established by the jacket color or Type B label.

Applications

Buyer taskWhy this item may fitApproval condition
Retain an existing SC/UPC duplex patch panelFour SC pairs connect to separate panel positionsOM3 plant, connector compatibility and approved pair-to-port map
Replace a documented MPO-to-SC harnessOne order record can preserve the existing connection patternCompare original and replacement drawings, branch reach and optical limits
Prepare a distributor repeat-order configurationFixed connector and fiber identity reduces ambiguous descriptionsApproved configuration identifier, revision, labels and jacket documentation

These are selection scenarios, not customer case studies. Supported network speed and reach depend on the equipment and the entire channel. They are not claimed for this product from the supplied data.

Order Guide

Keep OM3 fiber, eight active paths, MPO PC female, four SC/UPC duplex pairs and the approved Type B map fixed. Choose the requested overall length and jacket, then specify the branch reach on the drawing.

Order inputInformation to send
IdentityDocument 30 and the approved assembly drawing revision
Overall lengthSource-listed metric length; measurement endpoints and tolerance
FanoutRequired reach to each of the four SC duplex ports; equal or staggered arrangement for review
JacketRequested designation plus destination and installation requirements
MapMPO end view, SC pair identifiers and panel port schedule
AcceptanceAgreed optical limits, measurement scope, inspection and record requirements
QuantityQuantity per length/jacket combination and sample quantity if required
HandoverLabel wording, packaging and required approval documents

The source’s 39 length/jacket rows are retained in a separate review schedule without repeating the full product name in every row. Metric length controls: for example, 1 m ≈ 3.28 ft, 1.5 m ≈ 4.92 ft and 2 m ≈ 6.56 ft. Rounded imperial labels must not be treated as equivalent order lengths. Custom lengths, supported branch arrangements, stock, sample availability, MOQ and lead time are confirmation with BWNFiber.

Why Source from BWNFiber

Ask BWNFiber for a quotation tied to the approved SC panel map and assembly drawing. Keep any exceptions beside the original requirement so purchasing, receiving and repeat orders use the same configuration.

Request the inspection scope, continuity and polarity records, connector end-face acceptance criteria, optical test conditions and documentation included with the shipment. Fiber optic testing coverage and manufacturing traceability for this exact item are confirmation with BWNFiber. The source does not establish a verified certification, test percentage or delivery promise. If the branch connector is still undecided, compare the existing configurable fanout range before specifying this SC assembly.

Need a Configuration Review or Sample?

Request a quote for the SC duplex configuration. Send document 30, the SC panel model, eight-path drawing, overall length, branch reach, jacket, quantity and destination. Ask for the proposed specification, unresolved exceptions and available sample documentation before approving the order.

FAQ

MPO 8F OM3 to SC Duplex Type B Breakout Cable FAQ

How many SC connections does this assembly provide?

The supplied configuration has four SC duplex pairs, comprising eight individual SC terminations. Confirm the pair labels and panel destinations on the approved drawing.

Is this an optical splitter?

No splitter function is specified. The eight fibers are separate paths; the fanout groups those paths into branch connectors rather than dividing optical power.

Does MPO-8 identify the exact ferrule?

The source designation alone is insufficient. Request the physical connector format, end view and occupied-position map before approving the mating interface.

Is Type B enough to order the SC pair mapping?

No. Confirm every MPO position against its SC connector and panel destination, with viewing direction and key orientation stated.

Can these SC branches plug directly into LC ports?

No. SC and LC are different connector interfaces. Review a separate LC branch configuration or the complete adaptation path when the equipment uses LC.

Is this the OS2 SC/APC version?

No. This source specifies OM3 multimode and SC/UPC. Single-mode fiber and SC/APC require a different approved configuration.

Can polarity be selected as Type A or Type C on this page?

The supplied item is Type B. A different polarity is a separate engineering request and is not offered as an option for this item.

Are 30, 45 and 60 cm fanouts available in every length?

They are listed in the source, but their combination rules, measurement points and arrangement are confirmation with BWNFiber.

Does an OFNP option prove a certified assembly?

No. Request the exact cable marking and documentation applicable to the offered construction. A source-listed jacket name is not a certification record.

What speed, reach and loss are guaranteed?

The supplied document does not establish these guarantees. Review equipment requirements, the full channel and written optical acceptance limits before ordering.

Can I order a custom length?

Submit the required metric length, measurement points and tolerance for quotation. Feasibility and delivery are confirmation with BWNFiber.

Which documents should accompany a repeat order?

Use the accepted configuration identifier and drawing revision, length/jacket schedule, pair labels and agreed inspection record list. Confirm the documents actually included in the quotation.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.