This MPO 8 fiber OM3 to LC uniboot breakout cable brings eight multimode fiber paths from one MPO end to four LC/UPC duplex uniboot ends. It is intended for an OM3 connection schedule that keeps each pair together at the LC termination. Confirm the MPO interface drawing and all four pair destinations before ordering.
Product Overview
The supplied configuration is described as MPO-8/PC female to four LC/UPC uniboot duplex connectors, with OM3 50/125 μm fiber and an aqua jacket. Each uniboot carries a duplex pair through one boot. Select this format when the two fibers of a pair terminate at the same duplex port and the connector body fits the panel.
Eight fibers specify the number of optical paths. They do not identify the ferrule’s occupied positions or prove an SR4 pin map. The MPO component part number, end view and key orientation must resolve what “MPO-8” means for this build. This point matters when replacing a cable described as MPO-12 with eight active fibers.
Browse the MPO breakout and harness range for other branch formats. A full twelve-fiber, six-duplex harness is a different configuration, as is an eight-fiber assembly with standard LC duplex clips. Review other termination requests in the existing multi-configuration fan-out listing.
Key Features
- Eight OM3 multimode fibers arranged as four LC duplex pairs.
- LC/UPC uniboot terminations for paired routing at the destination.
- MPO/PC female, or unpinned, termination as stated in the source specification.
- Aqua cable jacket; verify fiber identity from the approved specification rather than color alone.
- Listed overall lengths from 1 to 50 m, subject to confirmation of the selected configuration.
- Four separately identified pair destinations for labeling, routing and acceptance review.
Technical Specifications
Specification notice: The values below come from supplied product material and are subject to configuration approval. The approved BOM, drawing and availability of each option are confirmation with BWNFiber before order release.
| Parameter | Configuration and confirmation required |
|---|---|
| Product reference | Document 25; not a verified manufacturer SKU |
| Fiber paths | 8 fibers / 4 duplex pairs |
| Fiber grade | OM3 multimode, 50/125 μm |
| MPO termination | Source designation MPO-8/PC (F); component identity, occupied positions and mating drawing: confirmation with BWNFiber |
| Branch connectors | 4 × LC/UPC uniboot duplex; body dimensions and latch design: confirmation with BWNFiber |
| Jacket color | Aqua |
| Overall lengths listed | 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m |
| Fanout lengths listed | 30 / 45 / 60 cm; source default 30 cm. Measurement points and tolerances: confirmation with BWNFiber |
| Polarity requests | A / B / C listed; approve a position-to-pair map for the chosen order |
| Jacket requests | LSZH / OFNP / OFNR listed; exact construction and supporting declarations: confirmation with BWNFiber |
| Optical acceptance | IL/RL limits, wavelengths, reference method and measurement scope: confirmation with BWNFiber |
| Mechanical conditions | Cable and branch diameters, bend radius, tensile limit and operating temperatures: confirmation with BWNFiber |
| Compliance | Source lists TIA/EIA-568.3-D, IEC 61754-7, IEC 61754-20, IEC 61753-1 and RoHS. Applicable editions and SKU evidence: confirmation with BWNFiber |
Selection Guidance
Match four paired endpoints to the port schedule
Use the table below to request a drawing. Pair labels P1–P4 are worksheet identifiers, not a supplied wiring map. Enter the actual MPO position numbers and LC A/B assignment from the approved drawing; do not infer them from fiber count or a Type B label.
| Pair | MPO positions / end-view reference | LC A/B assignment | Destination port | Branch length |
|---|---|---|---|---|
| P1 | To be confirmed | To be confirmed | Buyer input | Buyer input |
| P2 | To be confirmed | To be confirmed | Buyer input | Buyer input |
| P3 | To be confirmed | To be confirmed | Buyer input | Buyer input |
| P4 | To be confirmed | To be confirmed | Buyer input | Buyer input |
Include any intermediate adapters, trunks or cassettes when checking the transmit-to-receive path. The MPO channel polarity review addresses that complete path; this product request records only the four paired terminations.
Check service clearance before choosing uniboot
A uniboot changes how a duplex pair leaves the connector. It does not automatically reduce LC port spacing, provide a pull tab, or allow polarity reversal. Request the connector outline and check the boot exit, latch access and branch bend with adjacent ports populated. If one fiber must route to a separate port, specify individual terminations instead.
The SENKO uniboot example shows why field functions are component-specific. It is not evidence that this BWNFiber assembly uses that component. The supplied material describes this item as not field polarity-switchable; confirm the actual handling procedure before relying on that restriction.
Validate any SR4 application against the actual equipment
Four duplex pairs can be part of a supported parallel-optics breakout, but the passive harness does not create the host’s breakout mode. Supply both module part numbers, switch model, enabled mode and occupied MPO positions. An OM3 cable length must fit the complete link’s optical requirements, including the other components.
Cisco’s breakout explanation identifies MPO-12 interfaces for several breakout optics. It supports checking the exact interface instead of equating eight active fibers with a particular connector geometry. No Cisco compatibility claim is made for this unverified assembly.
Applications
| Connection task | When to consider this configuration | Required input |
|---|---|---|
| Four-pair OM3 panel distribution | Each duplex pair stays together at one LC port | Panel outline, four destination IDs and MPO map |
| Equipment breakout request | Both ends and the host mode explicitly support the requested link | Module part numbers, host mode and link budget |
| Replacement in an existing aqua cabling route | Fiber grade, pairing and mechanical fit match the installed assembly | Existing part number, drawing and route dimensions |
Do not substitute this OM3 configuration for a singlemode assembly. Do not assume a full twelve-fiber distribution requirement is satisfied by eight fibers. Jacket color and connector count alone are insufficient acceptance criteria.
Order Guide
Define the dimensions once
Use metres as the controlling order unit. One metre is approximately 3.28 ft; two metres are approximately 6.56 ft. Feet are reference conversions, not alternative order lengths. Mark the measurement endpoints and tolerance on the drawing, including whether overall length includes the branch section.
Record each P1–P4 leg from the breakout point to its agreed connector datum. The source lists 30, 45 and 60 cm fanout choices and a 30 cm default; do not apply that default before checking the actual port layout.
Select the requested configuration
| Field | Source-listed request | Release requirement |
|---|---|---|
| Polarity | Type A, Type B or Type C | Confirm actual pair map and end-view convention |
| Jacket | LSZH, OFNP or OFNR | Confirm exact construction and project acceptance documents |
| Length | Thirteen metric choices listed in Technical Specifications | Confirm datum, tolerance and optical path length |
| Other requests | Custom lengths, 0.9 mm legs, staggered fanout, pulling eyes | Feasibility and limits: confirmation with BWNFiber |
| Identification | OEM print, polarity labels and packaging | Approved text, label position and document revision: confirmation with BWNFiber |
The original 117 order combinations are retained in the accompanying order schedule. They describe source-listed requests, not 117 confirmed stocked products. The proposed code BWN-BO-M8PCF-4LCUNI-OM3-AQUA-{POL}-{JKT}-{LEN} also requires BWNFiber confirmation before use as an ordering identifier.
Why Source from BWNFiber
Bring BWNFiber a four-pair port schedule and a dimensioned routing requirement so the quotation can identify the requested assembly precisely. Ask for the build description, any exceptions and the document revision that will control the order. A change from uniboot to standard duplex, or from one MPO component to another, should be stated explicitly in the quotation.
Quality control and testing documents
For this eight-fiber build, request continuity and pairing results that cover all eight paths and retain the P1–P4 identification. Ask the test report to identify the assembly, test wavelengths, reference setup and applicable IL/RL limits. A connector-level limit should not be presented as the loss limit for the full installed link.
Acceptance record
Compare the delivered label with the drawing revision, verify the four destination labels, and check the reported results against the agreed test specification. The source cites IEC 61300-3-4 for attenuation measurement; the applied procedure, report availability and actual factory checks are confirmation with BWNFiber. Certification, MOQ, sample availability and delivery commitments also require confirmation for the quoted build.
Request a Four-Pair Configuration Review
Send the MPO mating interface, P1–P4 destination schedule, panel drawing, overall and branch lengths, jacket requirement, quantity and delivery destination. Include the equipment part numbers if the cable connects directly to optics. Request an OM3 uniboot configuration quotation with unresolved fields identified so they can be answered before approval.