Specify eight OM3 fiber paths from a female MPO PC connector to four LC/UPC duplex ends, with the Type B arrangement fixed for the approved build. This aqua harness is intended for a defined port map; connector identity, branch pairing and equipment compatibility must be checked together.

Product Overview

The supplied configuration is an MPO 8 fiber OM3 to LC duplex Type B breakout cable. It provides four duplex branch connections from one multi-fiber connector. It is a passive fiber assembly: it does not convert a port’s signaling rate or enable a switch breakout mode.

Use this configuration when the engineering schedule already calls for OM3 fiber, four LC duplex branches and a fixed Type B map. If these choices are still open, start with the MPO breakout and harness selection page. The designation “MPO-8” identifies eight active fibers in the supplied material; the ferrule format and populated positions remain confirmation with BWNFiber.

Key Features

  • Eight active OM3 multimode fibers, specified as 50/125 μm in the source.
  • One female, unpinned MPO PC end and four LC/UPC duplex ends.
  • Aqua identification color in the supplied configuration.
  • Factory-fixed Type B designation; approve the actual position-to-branch map.
  • Length and jacket choices recorded on one order schedule, with no need for separate pages for each length.
  • A branch-label record can tie each duplex pair to the intended destination port; availability of supplied labels is confirmation with BWNFiber.

Technical Specifications

The following values come from supplied product material. They are not independently verified manufacturing or compliance claims. Release the configuration only against an approved drawing and specification.

ParameterSupplied configuration or required confirmation
Document reference29; source reference, not a verified manufacturing SKU
AssemblyMPO to 4 × LC/UPC duplex; 8 active fibers
MPO endPC, female / unpinned
Ferrule formatSource uses MPO-8; geometry, key view and populated positions: confirmation with BWNFiber
FiberOM3 multimode, 50/125 μm
ColorAqua
PolarityType B, factory-fixed; signed position-to-LC pairing map: confirmation with BWNFiber
Overall lengthSource lists 1–50 m; measurement points, tolerance and availability: confirmation with BWNFiber
Fanout lengthsSource lists 30 / 45 / 60 cm; reference points and availability: confirmation with BWNFiber
Jacket choicesLSZH / OFNP / OFNR listed; exact construction and supporting declarations: confirmation with BWNFiber
Optical acceptanceMaximum insertion loss, minimum return loss, wavelength, reference method and measurement scope: confirmation with BWNFiber
Mechanical limitsBend radius, tensile limit, cable diameter and temperature range: confirmation with BWNFiber
ComplianceApplicable standards editions, product scope and declarations: confirmation with BWNFiber

Selection Guidance

Approve the map behind the Type B label

Request a connector end view with the viewing direction and key orientation stated. Record every occupied MPO position against its LC branch and A/B side. Label the four branch pairs consistently with the destination ports. A Type B name alone does not establish the complete transmit-to-receive path through adapters, trunks or cassettes. Use the channel polarity design workflow for that wider review.

Verify the equipment before assigning a data rate

Confirm the exact switch, software, transceiver part numbers, supported breakout mode and far-end optical interfaces. Cisco’s breakout overview explains that breakout depends on the equipment and optical implementation. Its examples are not compatibility approval for this BWNFiber cable. Do not approve 40G-to-four-10G or 100G-to-four-25G operation from the cable name alone.

Separate active fibers from the mating interface

Eight active fibers do not prove that the mating ferrule has only eight physical positions. Cisco’s 40G module data sheet describes parallel interfaces using a twelve-fiber connector format. Confirm the exact mechanical interface, populated positions, pinning and polish on both sides before ordering this assembly.

Define the installed route and acceptance scope

Measure the route, service slack and branch reach separately. Agree the assembly length endpoints, branch measurement origin and tolerances. Require the proposed maximum loss to fit the complete channel budget, including any additional connections. Keep an assembly test result separate from the installed link assessment.

Documents to agree before order release

Request the approved drawing revision, fiber and jacket specification, continuity map, end-face inspection criteria and optical test conditions. Confirm which reports are included with the quote. Manufacturing inspection coverage and shipment records for this item are confirmation with BWNFiber.

Applications

Buyer taskPotential fitRequired approval
Four duplex equipment connections from an MPO endpointDefined eight-path OM3 harness with LC duplex branchesExact optics, breakout support and lane map
Connection to existing duplex patchingBranches terminate at separate LC patch positionsFull channel continuity, pinning and loss budget
Reordering a fixed Type B assemblyRepeat the approved drawing and branch labelsSame revision, construction and acceptance limits

These are selection scenarios, not customer case studies. This OM3 configuration is not a substitute for an OS2 single-mode assembly or a full twelve-active-fiber harness. For a modular panel approach, compare the breakout cable versus cassette guide.

Order Guide

Keep Type B fixed for this configuration. Select length and jacket, then approve branch dimensions and labeling on the drawing. Polarity is not offered as a field-switchable feature in the supplied source.

Ordering fieldInformation to include
ConfigurationEight OM3 fibers, female MPO PC to four LC/UPC duplex ends, fixed Type B
Overall length in meters1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 listed in source; availability to confirm
JacketRequested LSZH, OFNP or OFNR construction and installation requirement
Branch geometryEqual or staggered reach; requested dimensions and measurement points
TraceabilityDrawing revision, branch labels and destination port schedule
AcceptanceContinuity, polarity, cleanliness and agreed optical limits
Commercial requestQuantity, destination, requested date and required documents

Use meters as the ordering unit. For reference, 1 m is about 3.28 ft and 1.5 m is about 4.92 ft; rounded feet labels must not become a different order length. Custom lengths, 0.9 mm legs, staggered branches and pulling eyes are source-listed requests, with feasibility confirmation with BWNFiber. The proposed order-code pattern in the source is not a confirmed catalog SKU.

Why Source from BWNFiber

Send BWNFiber one configuration record covering the connectors, branch map, jacket, route and acceptance criteria. Ask for a quote that identifies the proposed build and any exceptions. Use the same approved record for sample review, purchasing and receiving inspection.

Factory termination, OEM printing, inspection records, sample availability, delivery schedule and minimum order quantity require product-specific confirmation: confirmation with BWNFiber. The source’s standards list is not evidence of certification or a completed test. No speed, reach or delivery commitment is established here.

Need a Configuration Review or Sample?

Request a Type B configuration review with both endpoint part numbers, the complete channel map, length, jacket, branch reach, quantity and destination. Ask for the proposed drawing, acceptance limits, available sample documentation and commercial terms before release.

FAQ

MPO 8 Fiber OM3 to LC Duplex Type B Breakout Cable FAQ

Does Type B alone prove the correct LC pairing?

No. Approve a position-to-branch map with the viewing direction, key orientation, branch numbers and LC A/B sides stated.

Is the polarity adjustable after delivery?

The source describes a factory-fixed arrangement and does not offer field switching. Resolve any required change before ordering.

Are four duplex ends the same as eight simplex ends?

Both can carry eight fibers, but paired housings, branch handling and labels differ. Approve the duplex configuration shown on this drawing.

Does MPO-8 specify an eight-position ferrule?

The source does not establish the ferrule geometry. Confirm the physical interface and the eight occupied positions independently.

Can this harness enable a switch breakout mode?

No. The passive harness cannot add a mode unsupported by the switch or transceivers. Verify the exact equipment combination.

Can OM3 be used in a single-mode channel?

This supplied OM3 configuration should not replace the specified OS2 single-mode assembly. Re-select the cable for the actual optical interface.

Is every listed jacket suitable for a plenum?

Do not infer installation approval from a list of options. Request documentation for the selected jacket and the applicable installation requirement.

Is 1 m exactly 3 ft?

No. One meter is approximately 3.28 feet. State the metric length and measurement endpoints on the order.

What must a repeat order reference?

Use the approved drawing revision, fiber map, branch geometry, jacket specification, labels and acceptance limits.

Which optical reports are included?

Report availability is confirmation with BWNFiber. Agree the measurement scope, limits, wavelengths and identification before placing the order.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.