MPO Breakout & Harness Cable

MPO 8 Fiber OM3 to LC Duplex Breakout Cable

Eight OM3 fibers terminate in four LC duplex pairs for a documented MPO-to-LC channel layout. Confirm the MPO mating interface, branch pairing and equipment configuration before ordering this aqua-jacket assembly.

MPO Breakout & Harness Cable

Hero

Eight OM3 fibers terminate in four LC duplex pairs for a documented MPO-to-LC channel layout. Confirm the MPO mating interface, branch pairing and equipment configuration before ordering this aqua-jacket assembly.

Product Introduction

This MPO 8 fiber OM3 to LC duplex breakout cable is specified in the supplied product brief as one female MPO/PC end connected to four LC/UPC duplex ends. Its procurement role is a conventional duplex-branch OM3 harness, with connector details and channel mapping fixed on the approved drawing.

Eight active fibers and four duplex pairs describe the fiber paths; they do not establish the MPO ferrule geometry or transceiver compatibility. The brief uses “MPO-8.” Confirm the connector part number, occupied positions, key orientation and mating requirements before treating that label as a complete interface specification.

For other terminations or fiber categories, start with the MPO breakout and harness range.

Key Features

  • Eight active OM3 multimode fibers presented as four LC duplex pairs.
  • Female MPO/PC and LC/UPC terminations specified in the supplied brief; final connector BOM requires approval.
  • Aqua jacket identifies the requested construction; jacket color alone does not verify fiber grade or fire classification.
  • Overall length, branch reach and branch labels recorded separately on the assembly drawing.
  • Factory channel mapping selected for the documented path. Do not assume field polarity switching.

Specifications

The following is a review specification from the supplied brief, not a verified production datasheet. All listed supply options and product-specific limits are confirmation with BWNFiber before manual upload.

ParameterRequested configurationApproval evidence
Active fiber count8Continuity map for all eight paths
Branch presentation4 × LC/UPC duplexDrawing showing four paired destinations
FiberOM3 multimode, 50/125 μmApproved fiber/component specification
MPO endFemale, PC; described as MPO-8Part number, ferrule geometry, occupied positions and key orientation
Jacket colorAquaApproved construction record
Trunk outside diameter3.0 mm described as typicalActual diameter and tolerance; no default guarantee
Overall lengthRequested range 1–50 mMeasurement reference planes and tolerance
Branch lengthBrief lists 30, 45 or 60 cmConfirm equal or staggered branches; no automatic 30 cm default
Jacket requestLSZH, OFNP or OFNR listed in briefConfirm exact construction and applicable supporting documents
Channel mappingType A, B or C requested in briefEnd-to-end MPO-position-to-LC map; selected build is factory fixed
Optical acceptanceLimits not suppliedAgreed insertion loss and return loss criteria, wavelength and test method
ComplianceNo product-specific evidence suppliedApplicable declarations, standards editions and supporting records

LSZH, OFNP and OFNR must not be treated as interchangeable labels. Specify the installation requirement and request evidence for the exact jacket construction. A generic standards list is not proof that this assembly meets it.

Configuration and Application Selection

RequirementSelection decisionCheck before ordering
Four conventional LC duplex destinations on OM3Review this configurationExact pairing, labels and connector clearance
LC uniboot constructionRequest the uniboot configurationBoot construction and access requirements
Six LC duplex pairsReview a 12-active-fiber configurationThis eight-fiber assembly provides four pairs
Type B specified on the designRecord it as a build selectionVerify the full channel map, not only the polarity name
Single-mode opticsSelect an OS2 assembly appropriate to those opticsDo not substitute this OM3 harness

Parallel-optic breakout

A supported 40G SR4-to-four-10G or 100G SR4-to-four-25G installation may use an appropriate MPO-to-LC harness. Compatibility depends on the exact modules, switch platform, breakout mode, channel map and optical budget. A passive cable does not convert protocols or enable an unsupported switch mode.

Cisco’s breakout reference explains equipment-dependent breakout and MPO interfaces. This supports the selection method; it does not certify this BWNFiber assembly. Supply both-end equipment and optic part numbers for review.

Rack and panel distribution

For a documented OM3 patching route, identify the four destination pairs and the breakout position before setting the branch lengths. Include service loops and connector access in the route drawing. Consult the breakout versus cassette comparison when deciding the service boundary.

Order Guide

Use one configuration record instead of separate indexable pages for every length, jacket or polarity choice. Record all requested selections in the RFQ; availability is confirmation with BWNFiber.

  1. Record optic and host part numbers, intended operating mode and destination ports.
  2. Confirm the MPO part number, pin state, end face, ferrule layout and key orientation.
  3. Map all eight fiber positions to LC pair 1–4 and each transmit/receive destination. Request the drawing’s viewing convention.
  4. Specify trunk route, breakout location, overall length, branch reach and tolerances.
  5. Specify jacket requirements, labels, quantity, destination and acceptance documents.
  6. Approve the drawing and quotation revision before ordering or repeating a batch.

Length schedule

The brief lists these metric requests. Feet are approximate conversions, not separate nominal order codes or tolerance statements.

Requested lengthApproximate feet
1 m3.28 ft
1.5 m4.92 ft
2 m6.56 ft
3 m9.84 ft
5 m16.40 ft
7 m22.97 ft
10 m32.81 ft
15 m49.21 ft
20 m65.62 ft
25 m82.02 ft
30 m98.43 ft
40 m131.23 ft
50 m164.04 ft

The assembly length is not the permitted channel reach. Add the remaining fiber route and connection losses when checking the equipment’s channel requirements.

Drawing, Customization and Acceptance

Request confirmation of custom lengths, staggered branches, labels, packaging and jacket options for the selected construction. MOQ, lead time, sample availability and manufacturing capability are confirmation with BWNFiber; this draft makes no supply commitment.

Document to requestWhat the buyer should verify
Connector BOM and assembly drawingConnector identity, eight occupied paths, key orientation, branch pairing, dimensions and revision
Continuity reportEvery path matches the approved map and branch label
Optical reportPer-path limits, measured results, wavelength, reference arrangement, method and assembly identification
End-face inspection recordAgreed inspection criteria and traceable connector identification
Jacket/compliance evidenceExact supplied construction matches the project’s documented requirements
Sample approval recordPhysical routing, connector access and approved system operation before repeat procurement

Request the current product-specific test specification. IEC 61300-3-4 is named in the brief as a measurement-method reference; its applicable edition and implementation are confirmation with BWNFiber. No numerical insertion-loss or return-loss guarantee, certification, or universal test coverage is asserted here.

Related Products

Use the existing MPO/MTP fan-out selection to request another branch construction. For links that retain MPO at both ends, review MPO trunk cables or MPO conversion cables according to the required topology.

FAQ

Request a Configuration Review

Does eight fibers mean eight LC duplex connectors?

No. Eight fibers provide four duplex pairs in this requested assembly. Each duplex pair contains two fiber paths.

Is “MPO-8” enough to confirm the interface?

No. Obtain the connector part number, ferrule layout, occupied positions, pin state and key orientation. Active-fiber count alone does not define the full mating interface.

Does a female MPO mate with every SR4 module?

No. Confirm the actual mating component and its pins, keying and end face. A family name or module speed is insufficient.

Can this harness enable a switch’s breakout mode?

No. Confirm that the switch platform, software, port and optics support the intended breakout operation before choosing the cable.

Is Type B always the correct selection?

No. Use the end-to-end map for the actual path, including any trunks, adapters or panels. Specify the map and its viewing convention on the drawing.

Can polarity be changed in the field?

The supplied brief describes a factory-fixed build. Do not promise field switching; confirm the selected construction before ordering.

Is the 30 cm branch length automatic?

No. Request a dimensioned drawing. The final branch reach and tolerance must suit the four destination ports.

Does aqua color prove OM3 and jacket compliance?

No. Request the fiber specification and jacket documents for the supplied assembly. Color is not a substitute for component evidence.

Can I order 1 m as exactly 3 ft?

No. One metre is approximately 3.28 ft. Use one controlling unit and approved reference points to prevent length ambiguity.

Does a 50 m assembly guarantee a working 50 m optical channel?

No. Channel suitability depends on the optics, remaining fiber, connection losses and operating requirements. Assembly length and channel reach are different quantities.

What should accompany a repeat order?

Reference the approved part number and drawing revision, channel map, jacket, lengths, labels and acceptance criteria. Confirm any component changes before substitution.

Which documents establish the optical limits?

The agreed test specification and traceable report for the selected assembly. The supplied brief does not provide numerical limits, so these remain confirmation with BWNFiber.

Send an OM3 duplex-harness RFQ with both-end equipment references, connector requirements, eight-path channel map, route drawing, overall and branch lengths, jacket requirement, quantity and destination. Identify the drawing and test records needed for approval. Ask BWNFiber to confirm the build and commercial terms before placing an order.

Image and Implementation Notes

  • Image filename: mpo-8f-om3-to-lc-duplex-breakout-cable.jpg
  • Suggested alt after visual verification: Aqua OM3 MPO breakout cable with four LC duplex pairs.
  • No product image generated or supplied by this package; retain existing gallery positions and insert the user’s prepared photographs after checking the actual connector count and construction.
  • Breadcrumb: Home > Products > Data Center Solutions > MPO Cabling > MPO Breakout & Harness Cable > MPO 8 Fiber OM3 to LC Duplex Breakout Cable.
  • One H1. H2 sections contain H3 application, length and FAQ headings; H4 is unnecessary and should not be forced.
  • Use Product and BreadcrumbList only after actual SKU, final URL, image, brand and product facts are approved. Do not fabricate Offer, price, stock, review or rating data. FAQ remains visible content without a rich-result promise. Do not use Article or HowTo markup for this SKU.
  • Remove internal status and confirmation notes only after the underlying facts are approved. The HTML preview is noindex,nofollow and its inquiry forms cannot submit.
Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.