Connect eight OM3 fibers at one MPO end to eight individually terminated FC/UPC simplex ends. This configuration is intended for compatible multimode FC equipment or test connections where each fiber needs a separately identified termination. Confirm the MPO interface and branch-to-port assignment before specifying the assembly.
Product Overview
The BWNFiber MPO 8 fiber OM3 to FC breakout cable is specified in the supplied product material as an aqua, 50/125 μm multimode assembly with an MPO PC female end and eight FC/UPC simplex branches. It is a configuration for an installed FC interface, with eight individual fiber terminations rather than four pre-paired duplex connectors.
Use the endpoint drawing to establish whether this assembly fits your equipment. An eight-fiber description alone does not establish the MPO ferrule layout, populated positions or channel assignment. This FC-ended configuration is not a direct substitute for an MPO-to-LC duplex assembly on LC equipment.
Configuration status: The specifications below reproduce the supplied configuration for review. Released BOM, connector part numbers, fiber map and available order options: confirmation with BWNFiber.
Key Features
- Eight OM3 fibers terminating at eight FC/UPC simplex connectors.
- Aqua jacket and 50/125 μm multimode fiber specified in the source material.
- MPO PC female interface proposed for connection to a matching pinned interface; exact connector and key orientation require drawing approval.
- Individually identified FC ends allow the buyer to specify equipment port assignments without assuming duplex pairing.
- Overall length, branch reach, jacket requirement and acceptance records are confirmed together before ordering.
Technical Specifications
| Item | Source configuration / release condition |
|---|---|
| Product family | MPO breakout / harness cable |
| Fiber count | 8 active fibers, supplied specification; confirmation with BWNFiber |
| Fiber type | OM3 multimode, 50/125 μm, supplied specification; confirmation with BWNFiber |
| MPO end | Source designation: MPO-8/PC female; exact connector part number, ferrule geometry and populated positions: confirmation with BWNFiber |
| Branch ends | 8 × FC/UPC simplex; FC key dimensions and equipment mating interface: confirmation with BWNFiber |
| Jacket color | Aqua, supplied specification; confirmation with BWNFiber |
| Overall length | Source lists 1–50 m and custom requests; current availability, measurement datums and tolerance: confirmation with BWNFiber |
| Branch length | Source lists 30 / 45 / 60 cm and a 30 cm default; available combinations and datums: confirmation with BWNFiber |
| Jacket options | Source lists LSZH, OFNP and OFNR; material documentation, rating evidence and available constructions: confirmation with BWNFiber |
| Fiber mapping | Approved MPO position-to-FC label schedule; no mapping is inferred from the product title |
| Insertion loss / return loss | Limits, wavelengths, test method and supplied records: confirmation with BWNFiber |
| Cable diameter / bend radius | confirmation with BWNFiber |
| Operating / storage conditions | confirmation with BWNFiber |
| MOQ / lead time / order code | Quotation-specific; confirmation with BWNFiber |
Selection Guidance
Check the installed FC interface first
Confirm FC/UPC receptacles, the equipment’s multimode requirement and its connector key specification. Do not use jacket color as proof of fiber grade or connector polish. An FC/APC requirement must be reviewed as a separate configuration; it cannot be satisfied by changing the label on this FC/UPC assembly.
Distinguish this configuration from adjacent products
| Requirement | Selection route | What changes |
|---|---|---|
| Eight OM3 fibers to FC/UPC equipment | This configuration | Validate individual FC port assignments |
| OM4 fiber to FC/UPC equipment | Separate OM4 configuration review | Fiber specification, qualified BOM and system requirement |
| FC/APC equipment interface | Separate end-face and fiber review | Mating polish and connector qualification |
| LC duplex equipment ports | MPO-to-LC product selection | Branch connector and pair grouping |
| OS2 singlemode equipment | Separate singlemode assembly | Fiber, MPO end face and optical acceptance criteria |
These are selection boundaries, not declarations that every variant is currently available. Browse the MPO breakout and harness range for the appropriate product family.
Release the fiber map before the order code
Use one row per active fiber. Record the actual MPO position, the proposed FC label and the destination equipment port. The labels FC-01 through FC-08 below are a proposed worksheet convention, not an approved factory pinout.
| FC label | MPO populated position | Equipment port / signal | Verification record |
|---|---|---|---|
| FC-01 | To be confirmed | Buyer to specify | Pending |
| FC-02 | To be confirmed | Buyer to specify | Pending |
| FC-03 | To be confirmed | Buyer to specify | Pending |
| FC-04 | To be confirmed | Buyer to specify | Pending |
| FC-05 | To be confirmed | Buyer to specify | Pending |
| FC-06 | To be confirmed | Buyer to specify | Pending |
| FC-07 | To be confirmed | Buyer to specify | Pending |
| FC-08 | To be confirmed | Buyer to specify | Pending |
The source lists Type A, B and C ordering choices. A letter alone does not define this assembly’s eight FC destinations. Ask for the drawing that resolves key orientation, populated MPO positions and branch labels. For channel-level engineering, use the separate MPO polarity channel design guide.
Applications
- Installed FC equipment: connect only after confirming multimode operation, FC/UPC mating details and the equipment port schedule.
- Multimode test connections: specify the test instrument interface and reference arrangement before using separate FC branches to access individual fibers.
- Replacement harness procurement: compare the existing cable drawing and port labels with the proposed assembly; connector count and jacket color do not establish equivalence.
No transmission speed, link reach or transceiver interoperability is claimed from the cable name alone. The source’s 1–50 m range describes proposed assembly lengths, not a guaranteed optical reach.
Order Guide
Prepare the configuration request
- Provide both endpoint part numbers and photos or drawings of their interfaces.
- Confirm OM3, eight active fibers and eight FC/UPC simplex ends against the installed plant.
- Complete the fiber map and identify the drawing revision to be used for manufacture and acceptance.
- Specify overall length and branch lengths with measurement datums, tolerance and equal or staggered routing requirements.
- State the installation location and required jacket documentation. LSZH, OFNP and OFNR must be evaluated against the project specification; they are not interchangeable labels.
- Agree acceptance limits and records, quantity, packaging and requested delivery date before accepting a quotation.
Source-listed length references
Metric length controls the request below. Feet are rounded conversions, not additional stock SKUs. Availability of each length and jacket/polarity combination: confirmation with BWNFiber.
| Length (m) | Approximate length (ft) |
|---|---|
| 1 | 3.28 |
| 1.5 | 4.92 |
| 2 | 6.56 |
| 3 | 9.84 |
| 5 | 16.40 |
| 7 | 22.97 |
| 10 | 32.81 |
| 15 | 49.21 |
| 20 | 65.62 |
| 25 | 82.02 |
| 30 | 98.43 |
| 40 | 131.23 |
| 50 | 164.04 |
Customization requests
Include requested branch lengths, equal or staggered legs, port labels, jacket requirement and packaging in the RFQ. Availability, engineering feasibility and any minimum quantity: confirmation with BWNFiber. Do not treat a sample request as confirmation of production capability or delivery timing.
Why Source from BWNFiber
Request a configuration-specific quotation that identifies the eight FC destinations, the MPO interface and the dimensional drawing. Compare the response with your installed port schedule so that procurement, installation and acceptance use the same description.
If your required termination differs, review the current fanout configuration range. For background on configuration terminology, see MPO breakout cable types.
Quality Control and Test Documentation
Ask BWNFiber to confirm which inspection and optical test records can accompany the selected build. The acceptance request should identify continuity for all eight fibers, branch identification, connector end-face inspection, insertion-loss limits and measurement conditions. If return loss is required, state the relevant interface, limit and method separately.
Test coverage, report format, traceability, sampling plan and applicable certificates: confirmation with BWNFiber. No generic family-level loss specification is used here as a guaranteed limit for this configuration. Request written evidence for any named standard or regulatory declaration before including it in the purchase order.