MPO Breakout & Harness Cable

MPO 8 Fiber OM3 to FC APC Breakout Cable

The supplied configuration, availability and capabilities require BWNFiber confirmation(confirmation with BWNFiber). This document does not certify an assembly or approve an order. Administrative notes in this section are for the reviewer, not the eventual live product body.

MPO Breakout & Harness Cable

Publication status

The supplied configuration, availability and capabilities require BWNFiber confirmation(confirmation with BWNFiber). This document does not certify an assembly or approve an order. Administrative notes in this section are for the reviewer, not the eventual live product body.

Hero

Specify an MPO 8 fiber OM3 to FC APC breakout cable only when the equipment documentation calls for OM3 multimode fiber and FC/APC mating interfaces. The proposed assembly connects one MPO female end to eight FC/APC simplex ends. Confirm the connector part numbers, occupied MPO positions and branch mapping before requesting a build.

CTA: Request an Interface Review

Product Overview

This configuration is intended for a project that must route eight individual OM3 fibers from an MPO interface to FC/APC ports. Its defining requirement is the FC/APC endpoint. A drawing that lists only “FC” is not enough to select it: the receiving port specification must identify the polish and mechanical interface.

The supplied product brief describes an aqua assembly with an MPO-8/PC female connector and eight FC/APC simplex branches. These are proposed build details, subject to BWNFiber confirmation(confirmation with BWNFiber). Ask for the approved component list and assembly drawing before placing the configuration on a purchase order.

This passive cable routes fibers. It does not change fiber mode, convert an optical protocol or establish equipment compatibility by itself. Use the MPO breakout and harness range if you are still comparing endpoint types.

Key Features

  • Eight individually identified simplex branch connections, as described in the supplied brief.
  • OM3 50/125 μm fiber and an aqua jacket proposed for the assembly.
  • MPO female interface specified separately from its fiber-position map.
  • FC/APC branch identity retained as a mandatory equipment check.
  • Overall length, branch reach and label sequence recorded as separate drawing fields.
  • Optical acceptance limits to be agreed for the exact configuration before order release.

Technical Specifications

Specification notice: The values below describe the supplied proposal. They are not a released BWNFiber specification; each requires BWNFiber confirmation(confirmation with BWNFiber).

ItemProposed configuration or required decision
Active fibers8; document the occupied MPO positions
FiberOM3 multimode, 50/125 μm
MPO endDescribed as MPO-8/PC female; verify ferrule format, pinning and key orientation
Branch ends8 × FC/APC simplex; verify connector part number, keying and receiving port
Jacket colorAqua; color does not establish optical compatibility
Overall lengthSource lists 1–50 m; define measurement points and tolerance on the drawing
Branch lengthSource lists 30, 45 or 60 cm; confirm each leg and the reference datum
Jacket optionsSource lists LSZH, OFNP and OFNR; require evidence for the selected cable construction
PolaritySource lists A/B/C; the approved position-to-branch map governs the order
Insertion loss / return lossNo approved limits supplied; agree wavelength, method, launch/reference conditions and acceptance limits
Availability / MOQ / lead timeConfirm in the quotation; no stock or delivery commitment is established here

Selection Guidance

Confirm the FC endpoint first

Obtain the equipment model, port drawing and FC connector specification. Do not replace an FC/UPC requirement with this FC/APC proposal. If the equipment calls for a different polish or fiber mode, request a separately identified configuration through the assembly product range.

Record all eight fiber routes

“MPO-8” alone does not show where the eight active fibers sit in the ferrule. Request a drawing showing the connector face, viewing direction, key position, pinning, occupied positions and FC branch labels. Check every branch against the equipment port list. Do not infer a numbered map from Type A, B or C alone.

Check the complete optical path

Use the equipment specification to establish the permitted fiber type, optical interface and total channel loss. Include all connectors and intermediate patching in that review. There is no approved speed, reach or transceiver compatibility claim for this proposed FC/APC assembly.

Applications

Consider this configuration for a documented OM3 system whose receiving ports explicitly require FC/APC, subject to engineering validation. Potential evaluation contexts include equipment integration and replacement of a drawing-controlled assembly; these are use cases, not BWNFiber customer references.

Do not select it as a generic SR4-to-LC harness. Cisco’s 40G QSFP module documentation identifies MPO/MTP interfaces for applicable SR4 modules; supported breakout operation also depends on the equipment and destination interfaces. That documentation does not approve this FC/APC configuration.

Order Guide

Send a configuration record

Required inputWhat to provide
Endpoint evidenceEquipment model, port specification and required FC polish
Connector definitionMPO and FC part numbers or approved interface drawings
Fiber routingEight occupied positions mapped to eight labeled FC ends
DimensionsOverall length, individual leg lengths, datum points and tolerances
Installation conditionsRouting space, bend constraints and required cable rating
AcceptanceOptical limits, test wavelengths, reference conditions and report format
Commercial requestQuantity, destination, requested date and sample requirement

Length requests

The source lists 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 and 50 m. Treat these as requested lengths pending confirmation, not as stocked items. Use meters as the order authority. For reference, 1 m is approximately 3.28 ft, 1.5 m is 4.92 ft and 50 m is 164.04 ft.

Equal or staggered legs, 0.9 mm branch construction, pulling accessories, custom lengths and OEM markings are inquiry items from the source brief. Their feasibility is subject to BWNFiber confirmation(confirmation with BWNFiber). Do not use the source’s suggested order-code pattern as a released part number.

Why Source from BWNFiber

For this requirement, focus the supplier review on three deliverables: a confirmed FC/APC component identity, an approved eight-fiber map and an agreed optical acceptance record. Ask BWNFiber to confirm which drawings, sample checks and shipment records can be provided for the proposed build. Fiber optic manufacturing and fiber optic testing capabilities for this configuration require documented confirmation; this page does not claim that testing has already been performed.

Quality and testing review

Request the proposed inspection scope, continuity and mapping check, end-face inspection criteria, insertion-loss method and return-loss method. Use the fiber cable testing overview to prepare questions for the technical reviewer. Have the technical reviewer approve the applicable wavelengths and limits. Do not carry single-mode APC return-loss values into this OM3 proposal. Standards references or a RoHS statement in a draft are not a certificate or a test report.

Need a Configuration Review or Sample?

Send the FC port specification, MPO interface drawing, eight-branch map, lengths, jacket requirement and quantity to request a configuration review. Ask for written confirmation of feasibility, sample scope, price and delivery before releasing an order.

FAQ

Editorial release notes

Why must FC/APC be confirmed on an OM3 assembly?

The receiving equipment must require that exact fiber and connector combination. An FC label or an aqua jacket does not establish the polish, keying or mating requirements.

Can I use this for FC/UPC equipment?

Do not approve that substitution. Provide the FC/UPC requirement and request a separately identified assembly with matching interfaces.

Does MPO-8 define the occupied fiber positions?

No position drawing is supplied here. Obtain the ferrule layout and the eight active positions before approving the map.

Is the MPO end unpinned?

The brief specifies female. Verify that definition against the approved connector part number and its mating interface before ordering.

Is PC polish required for every OM3 MPO cable?

Do not use fiber grade alone to select connector polish. PC is the description in this proposal; the component and mating-interface specifications must establish the actual requirement.

Is this an SR4 breakout cable?

No SR4 compatibility has been established for this proposal. Check both equipment interfaces and supported breakout operation; the FC/APC ends are not LC ends.

Can I order by Type B alone?

Include a full connector-to-branch map. A polarity name does not replace the occupied-position, viewing-direction and label definitions.

Which insertion-loss limit applies?

No released limit is supplied. Request limits and test conditions for the exact assembly and check them against the equipment’s channel budget.

Are the listed lengths and jackets in stock?

Stock has not been verified. Confirm length, jacket construction, quantity, MOQ and delivery in the quotation.

What should I approve before a repeat order?

Approve the component list, revision-controlled drawing, labeling, optical acceptance criteria and any agreed sample. Reference the same revision on the repeat purchase order.

Proposed schema: WebPage plus BreadcrumbList. Add Product only after identity and visible attributes are verified; do not invent Offer, price, rating, review, certification or SKU fields. No FAQ/HowTo rich-result promise. Keep the exact product queries on this page; use broad category phrases only for navigation. Human engineering approver, claims registry and production URL remain pending. The photo alt above is provisional until the actual image is inspected. No product images are generated.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.