MPO Breakout & Harness Cable

6-Fiber OM3 MPO to 3 LC Duplex Breakout Cable

Specify six active OM3 fibers terminating in three LC duplex pairs. Confirm the MPO interface and occupied fiber positions against the mating equipment before approving this project configuration.

MPO Breakout & Harness Cable

Specify six active OM3 fibers terminating in three LC duplex pairs. Confirm the MPO interface and occupied fiber positions against the mating equipment before approving this project configuration.

Product Overview

This 6-fiber OM3 MPO to LC duplex breakout cable proposal is intended for a project requiring three duplex fiber pairs. Six active fibers and three LC duplex pairs describe the proposed termination count; they do not establish the MPO ferrule format or its populated positions. The supplied specification calls the connector “MPO-6,” but no approved connector part number or assembly drawing accompanies that description.

Review this configuration with BWNFiber before selecting it for a bill of materials. If the requirement is actually for six LC duplex pairs, select a 12-fiber assembly instead. If a larger MPO interface carries only six populated positions, that interface and its position map must be named explicitly in the final specification.

Key Features

  • Proposed six-fiber OM3 multimode construction with three LC/UPC duplex terminations.
  • Pair-level identification: specify Pair 1, Pair 2 and Pair 3 separately from MPO position numbers.
  • Interface review before ordering: approve the connector part number, key orientation, pin state and end-face finish together.
  • Project-defined overall and branch lengths, with measurement reference points stated on the drawing.
  • A six-row continuity schedule to connect each populated MPO position to one identified LC termination.

Technical Specifications

Specification notice: proposal based on supplied material. Every SKU-specific item below requires BWNFiber confirmation (confirmation with BWNFiber); this table is not an approved manufacturing specification.

ParameterProposed requirementApproval needed
Active fiber count6Confirm assembly drawing and continuity map
LC termination count3 duplex pairs / 6 individual LC terminationsConfirm pairing, labels and clips
FiberOM3 multimode, 50/125 μmApproved fiber specification
MPO interfaceUnresolved; source designation “MPO-6”Connector manufacturer and exact part number; ferrule geometry and populated positions
MPO pin state and polishFemale / PC in sourceConfirm mating interface and finish; do not substitute based on wording alone
LC polishUPC in sourceConfirm connector BOM
ColorAqua in sourceConfirm cable and branch identification
Overall lengthSource lists 1–50 m and custom requestsApproved lengths, tolerance and measurement endpoints
Branch lengthSource lists 30 / 45 / 60 cmApprove each branch; no default is assumed
JacketLSZH, OFNP or OFNR requested in sourceConfirm actual cable marking and applicable evidence for the installation
Optical acceptanceNot suppliedSpecify loss limits, wavelength, reference method and tested path
Availability, MOQ and deliveryNot establishedProject quotation required

Six-fiber connection schedule

Fill in the actual MPO position for each LC termination. The row numbers below identify review items; they are not an assigned MPO pinout.

Review rowLC destinationMPO positionApproval evidence
1Pair 1 — ATo be specifiedDrawing + continuity result
2Pair 1 — BTo be specifiedDrawing + continuity result
3Pair 2 — ATo be specifiedDrawing + continuity result
4Pair 2 — BTo be specifiedDrawing + continuity result
5Pair 3 — ATo be specifiedDrawing + continuity result
6Pair 3 — BTo be specifiedDrawing + continuity result

Selection Guidance

Confirm the intended connection count

Your requirementAssembly to reviewWhy it matters
Three duplex pairsThis six-active-fiber proposalSix individual terminations form three pairs
Six duplex pairsA 12-active-fiber harness“6 LC duplex” means twelve fibers, not six
A conventional four-lane SR4 breakoutAn equipment-approved eight-active-fiber mapThis six-fiber proposal is not a complete four-pair SR4 breakout
Six active fibers within a larger MPO interfaceA drawing-defined partially populated assemblyOccupied positions cannot be inferred from the active count

Approve the interface before the cable options

First identify the mating connector. Then approve the six occupied positions and LC pairing. Only after these agree should the order specify branch geometry, jacket and length. A Type A, B or C label alone does not identify this unverified six-fiber assembly. For whole-channel design, use the MPO polarity and channel design guide.

Applications

Consider this proposal for an indoor OM3 distribution arrangement requiring exactly three documented duplex pairs between an approved MPO interface and LC terminations. A lab harness or a project-specific patching assembly can be reviewed on the same basis; these are use cases for assessment, not claimed customer installations.

The cable does not convert protocols or create additional optical lanes. Equipment, populated positions and the complete link budget determine whether a proposed connection is usable. Do not infer a supported data rate or distance from OM3 or the jacket color alone.

Order Guide

Send the following information together so that a quote addresses one identifiable assembly:

  1. Exact mating equipment and connector part number, including an interface drawing if available.
  2. Required six MPO positions, three LC pair assignments and the viewing orientation used on the drawing.
  3. Overall length, tolerance and connector reference points; state each fanout length separately.
  4. Installation location, destination country and requested jacket marking or project compliance evidence.
  5. Quantity, requested delivery date, labeling and packaging requirements.
  6. Optical acceptance limits and the test record required with the assembly.

Custom requests

The source mentions staggered branches, 0.9 mm legs, pulling eyes and OEM printing. Availability for this proposal is confirmation with BWNFiber. List these as requested options in the RFQ; do not treat them as included features. The source order-code pattern is also unapproved and must not be used as a released purchasing code.

Why Source from BWNFiber

Ask BWNFiber to review the proposed build against the same six-fiber schedule used by your engineering team. Before supplier selection, request a connector BOM, dimensioned assembly drawing, agreed acceptance specification and quotation linked to one revision. Manufacturing availability and the documents BWNFiber can supply for this configuration are confirmation with BWNFiber.

Quality control and acceptance documents

Request continuity evidence for all six paths and identification of any unused positions. Optical results should state the measured path, wavelength, reference setup, limit and result. Passing an optical loss limit does not replace verification of the correct LC pair assignment. Standards listed in the source are references requiring applicability review; they do not prove product certification or compliance.

Need a Configuration Review or Sample?

Send your mating-interface drawing and three-pair connection schedule to BWNFiber, together with quantity, lengths and project location. Ask for feasibility, specification and quotation review before ordering. Sample availability, lead time, MOQ and testing scope are confirmation with BWNFiber.

Compare other connector and fiber arrangements in the MPO breakout and harness cable range. For the current broad product entry, review the existing breakout/fanout listing; it does not validate this proposed six-fiber interface. For broader terminology and assembly selection, read the breakout cable selection guide.

FAQ

6-Fiber OM3 MPO to 3 LC Duplex Breakout Cable FAQ

Does six fibers mean six LC duplex connectors?

No. Six fibers provide three two-fiber LC duplex pairs. Six LC duplex pairs require twelve fibers.

Is the MPO-6 connector designation approved?

No approved connector part number was supplied. Confirm the physical interface and populated positions before releasing this specification.

Can the assembly use six positions of an MPO-12 connector?

That is a different physical-interface description and requires a verified drawing. Do not assume it is the supplied product or create a second near-identical page automatically.

Can it serve a complete four-pair SR4 breakout?

No. A six-active-fiber assembly does not provide four duplex pairs. Use the exact equipment-approved assembly and lane map.

Does the female designation settle mating compatibility?

No. Pin state is one field; ferrule format, key orientation, finish and position mapping must also match.

Can I order it by Type A, B or C alone?

No. The proposed six-fiber configuration requires the actual position-to-LC map. Do not infer that map from a generic polarity label.

Is 30 cm the confirmed branch length?

No. It appears as a default in the source but has no approved drawing. Specify each required branch length and measurement reference.

Are 1–50 m lengths available from stock?

The source lists that range, but stock and approved configurations have not been established. Availability is confirmation with BWNFiber.

Are LSZH and OFNP interchangeable descriptions?

Do not treat them as interchangeable approvals. Submit the installation requirement and request evidence for the actual jacket construction and marking.

Which records should accompany a sample request?

Request the connector BOM, six-path continuity schedule, dimensioned drawing and agreed optical acceptance requirements, all tied to one assembly revision.

Can the cable change an optical data rate?

No. It is a passive connection proposal. Supported operation depends on the equipment and complete link design.

What should I send first for a quotation?

Send the mating-interface evidence and three-pair connection schedule first, followed by lengths, jacket requirements, quantity and destination.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.