Connect a compatible MPO-24 interface to 24 individually identified LC ports with an MPO-24 OS2 to LC simplex breakout cable. This supplied configuration specifies an APC female MPO end, LC/UPC simplex branches and a yellow single-mode cable. Submit the port map and optical acceptance requirements for a configuration quote.
Product Overview
This assembly provides 24 separate fiber paths between one MPO-24 connector and 24 LC simplex connectors. It is intended for a defined single-mode panel or distribution connection where each LC termination must be routed and identified individually. It is a passive fiber transition; the cable does not change an optical signal’s speed, wavelength or transmission protocol.
The source identifies OS2 9/125 μm fiber, an unpinned MPO/APC connector and LC/UPC branch ends. The approved ferrule end view, branch map and product drawing remain confirmation with BWNFiber. Treat these as the configuration under review, not a verified stock item.
For a different connector arrangement, start with the MPO breakout and harness selection page. Use this product page when the requirement is specifically a 24-path OS2 assembly with individually handled LC ends.
Key Features
- One MPO-24/APC female interface to 24 LC/UPC simplex terminations, as specified in the source.
- Separate branch identification for a panel schedule with 24 individually assigned fiber paths.
- OS2 single-mode fiber and a yellow jacket in the proposed construction.
- A requested low-loss grade at the MPO end; the approved maximum and measurement scope must be stated in the quotation.
- Factory-selected fiber mapping; the source does not offer field polarity switching.
- Overall and branch lengths recorded separately so the fanout reaches the actual panel positions.
Technical Specifications
Specification notice: The following values come from the supplied draft. Product identity, available options and performance require the approved BWNFiber specification before release.
| Parameter | Supplied configuration / release condition |
|---|---|
| Connection | One MPO-24 to 24 LC simplex connectors |
| Fiber count and type | 24 paths; OS2 single-mode, 9/125 μm |
| MPO termination | APC, female / unpinned; end-view drawing: confirmation with BWNFiber |
| LC terminations | 24 × LC/UPC simplex; individual branch labels to be approved |
| Appearance | Yellow jacket; confirm against the final cable construction |
| Trunk and branches | Source lists 3.0 mm trunk and 2.0 mm or 0.9 mm branches; construction and availability: confirmation with BWNFiber |
| Overall lengths | Source lists 1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m; tolerances: confirmation with BWNFiber |
| Fanout lengths | Source lists 30 / 45 / 60 cm and a 30 cm default; measurement endpoints and approved default: confirmation with BWNFiber |
| Mapping | Source lists Type A / B / C; each offered map requires a 24-position drawing |
| Jacket requests | LSZH / OFNP / OFNR listed; exact material, marking and documentation: confirmation with BWNFiber |
| MPO optical grade | Low loss requested; maximum insertion loss, minimum return loss and test conditions: confirmation with BWNFiber |
| LC optical limits | Separate LC/UPC acceptance limits: confirmation with BWNFiber |
| Mechanical and environmental limits | Bend radius, pulling load, temperature and durability: confirmation with BWNFiber |
| Standards and declarations | Applicable editions, test scope and SKU-specific declarations: confirmation with BWNFiber |
Selection Guidance
Match the panel interface and individual LC positions
Record the connector behind the MPO adapter, including its pin state, polish and key orientation. An ordinary adapter housing does not supply the mating connector’s guide pins. Confirm the complementary mating interface for this female end. Do not mate an APC end face directly against a UPC end face; different polish types at opposite ends of this cable are separate connections.
Give each LC branch a unique label, and map it to an MPO position and a destination port. Request a drawing with the viewing direction and key orientation stated. A Type A, B or C label alone is insufficient to approve the 24-position routing. Review the complete channel using the MPO polarity design workflow.
Distinguish simplex routing from duplex presentation
| Requirement | This configuration | What to confirm |
|---|---|---|
| Individual LC panel positions | 24 separately handled LC simplex ends | Branch labels and destination port schedule |
| Paired LC presentation | Not supplied as 12 duplex-clipped connectors | Request a separately approved duplex arrangement |
| Transceiver breakout | No module or lane-map compatibility established | Exact module, host breakout mode and complete fiber map |
| MPO backbone continuation | Branch ends terminate in LC | Choose the appropriate MPO-to-MPO trunk where required |
Twenty-four simplex connectors are not evidence of 24 duplex links. Pair assignment, where the application needs pairs, comes from the channel design. Do not select this assembly as a direct DR4 or PSM4 breakout from its fiber count alone.
Specify the low-loss acceptance requirement
Separate the MPO maximum insertion-loss limit from the LC limit and from the whole-path budget. Ask which measurement covers a mated pair and which covers an assembly path. Record wavelength, reference setup, test direction and acceptance limits. A typical value describes expected performance under stated conditions; it is not a guaranteed maximum.
The attachment lists numerical IL/RL limits but supplies no approved report or test specification. Those figures are retained in the audit claims register for confirmation and are not promoted to guaranteed product performance here. Obtain the approved per-path limits before allocating this assembly to the channel loss budget.
Receiving record for the 24 paths
For each branch, record: MPO position, LC label, destination port, continuity result, agreed optical result and record identifier. Use the same drawing revision for purchasing, inspection and installation. Fiber optic testing coverage and the records available with this assembly are confirmation with BWNFiber.
Applications
| Candidate use | Selection reason | Required approval |
|---|---|---|
| OS2 distribution panel with individual LC positions | Each branch can follow a named panel position | MPO mating interface and all 24 destinations |
| Single-mode enclosure fanout | Separate legs can follow the enclosure layout | Furcation position, branch lengths and handling protection |
| Defined low-loss panel connection | Optical grade can be specified for the allocated budget | Confirmed maximum limits and complete path calculation |
These are selection scenarios, not BWNFiber customer case studies. No data rate, transmission reach or module interoperability is guaranteed by the assembly name. For enclosure routing background, consult the fanout construction guide; the approved product drawing controls this order.
Order Guide
- Identify the MPO mating component and the LC destination panel.
- Supply a 24-position map with viewing direction, key orientation and branch labels.
- Select the metric overall length and state its two measurement endpoints.
- Define the furcation location and each branch length, including any stagger.
- Specify the required jacket, installation environment and documentation.
- Agree the optical limits, reporting scope, quantity and drawing revision.
| Request field | What to send |
|---|---|
| Product reference | 3_mpo-24f-os2-low-loss-to-lc-simplex-breakout-cable; document reference, not an approved part number |
| Length | One source-listed metric length or a custom request |
| Mapping | Requested A / B / C designation plus the actual approved fiber map |
| Branch layout | 24 individual destination labels; equal or staggered lengths |
| Jacket | Requested LSZH / OFNP / OFNR plus installation requirements |
| Optical acceptance | MPO and LC maximum limits, wavelengths and measurement scope |
| Commercial request | Quantity, destination, required date and packaging needs |
The original 117 order combinations are consolidated into three option dimensions: 13 lengths, three mapping requests and three jacket requests. All combinations remain in the accompanying order-options file; they are not confirmed stock. Lengths are controlled in meters. For example, 1 m is approximately 3.28 ft, and 2 m is approximately 6.56 ft.
Custom lengths, 0.9 mm branches, staggered layouts, pulling eyes, labels, sample availability, MOQ and lead time: confirmation with BWNFiber. A pulling-eye request also requires an approved load and handling instruction.
Why Source from BWNFiber
Ask BWNFiber to quote against one configuration record that connects the drawing, branch map, optical acceptance and order reference. This gives procurement and receiving teams a common basis for comparing the offered build and checking repeat orders.
Request the supporting specification, exact jacket documentation and available inspection records. Fiber optic manufacturing capability, inspection coverage and traceability for this build must be supported by product-specific evidence: confirmation with BWNFiber. The supplied draft does not establish certification, production capacity or a guaranteed response time.
Need a Configuration Review or Sample?
Request a 24-path configuration quote with the MPO mating part, LC port schedule, overall and branch lengths, jacket requirement, optical limits and quantity. Ask for the proposed drawing and any exceptions before approving a sample or order.
