Product Overview
This MPO 24 fiber OM3 to LC duplex breakout cable is specified in the supplied product brief as a 24-fiber, aqua assembly with one MPO-24/PC male connector and twelve LC/UPC duplex ends. It is intended for a compatible Base-24 distribution interface feeding an LC panel or other matched duplex connections.
Twelve duplex ends account for 24 individual fiber terminations. They do not establish an Ethernet speed, transceiver breakout mode or end-to-end polarity. The connected equipment and approved fiber map determine how each pair is used.
Configuration notice: The product identity above comes from the supplied brief. The production drawing, connector BOM and performance limits still require approval — confirmation with BWNFiber. Final specifications are subject to the approved drawing and quotation. This is a proposed configuration, not a statement of stock availability.
Key Features
- One MPO-24/PC male, pinned interface, as specified in the supplied brief.
- Twelve LC/UPC duplex ends for a 24-fiber distribution layout.
- OM3 multimode fiber, nominal 50/125 µm, with an aqua jacket.
- Individual duplex destinations can be specified in a port schedule before quotation.
- Overall length, branch reach, labels and the complete fiber map are reviewed together.
Technical Specifications
| Item | Specification or approval requirement |
|---|---|
| Proposed configuration | 1 × MPO-24/PC male to 12 × LC/UPC duplex |
| Fiber count | 24 fibers; 12 duplex pairs |
| Fiber type and jacket color | OM3 multimode, 50/125 µm; aqua, per supplied brief |
| MPO interface | Male means guide pins are present; verify the connector on the opposite side of the adapter |
| Mating condition | Compatible unpinned MPO-24 connector, matching interface geometry, polish and keying |
| Branch connector | LC/UPC duplex; clip orientation, boot and labeling require drawing approval |
| Overall length | Source proposes 1–50 m (approximately 3.28–164.04 ft); availability and measurement reference: confirmation with BWNFiber |
| Trunk / branch diameter | Source proposes 3.0 / 2.0 mm; construction and tolerances: confirmation with BWNFiber |
| Branch reach | Source proposes 30 / 45 / 60 cm or project dimensions; no default is approved: confirmation with BWNFiber |
| Jacket requirement | Specify the required rating and supporting cable evidence; source lists LSZH, OFNP and OFNR: confirmation with BWNFiber |
| Fiber mapping | Source lists A / B / C; approve all 24 positions, MPO viewing direction, key orientation and LC pair orientation: confirmation with BWNFiber |
| Insertion loss / return loss | Guaranteed limits, test wavelength, reference method and report format: confirmation with BWNFiber |
| Mechanical limits | Bend radius, pulling limits, operating temperature and storage temperature: confirmation with BWNFiber |
| Certification / compliance | No assembly-level certification is established by this draft; request applicable documents: confirmation with BWNFiber |
Selection Guidance
Confirm the other connector before choosing male MPO
An adapter aligns and holds the connection; the mating connector supplies the pin or hole arrangement. A pinned MPO connector must meet a compatible unpinned connector. Do not decide gender from an adapter opening or the word “cassette” alone. Check the connector behind the panel and record the actual part number.
Separate a distribution harness from a transceiver breakout
This configuration distributes 24 fibers to twelve duplex ends. It is not a direct substitute for an MPO-12, eight-active-fiber SR4 breakout assembly. A cable cannot create a breakout mode that the switch or transceiver does not support. For an equipment-side request, send both transceiver models and the switch port-mode requirement before selecting a different assembly.
Approve the complete map
For every LC pair, record its panel port, A/B orientation and the two corresponding MPO positions. Include the MPO end-face viewing direction, key position and drawing revision. A label such as “Type B” alone is not an adequate production instruction for this 24-position assembly.
Check branch reach and the channel budget
Measure to each destination connector, allowing the routing and service space required by the actual cable construction. State whether overall length runs from mating plane to mating plane or uses another agreed reference. Add the relevant mated-connection and fiber losses for each duplex path; do not treat a single connector limit as a complete-channel guarantee.
If the enclosure design is still open, compare the breakout and cassette architectures before choosing the assembly.
Use the MPO polarity channel-design reference for the wider channel review. Confirm any component-specific recommendation against the approved drawing.
Applications
- A compatible OM3 Base-24 trunk connection feeding twelve identified LC duplex destinations.
- Panel distribution where a single 24-position interface is required by the approved port plan.
- A cassette-related build only after checking the internal space, connector behind the rear adapter, branch protection and the complete channel map.
These are selection scenarios, not claims of a completed BWNFiber project. Do not use this assembly to infer support for SR4, SR8, SR10 or a particular data rate solely from the fiber count. For alternative architectures, review the MPO breakout and harness range.
Order Guide
Proposed option set
| Order field | Source proposal | What must be agreed |
|---|---|---|
| Overall length | 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 or 50 m | Required length, reference points and tolerance |
| Fiber map | A / B / C labels in source | A signed 24-position drawing, not a name alone |
| Jacket | LSZH / OFNP / OFNR in source | Applicable cable rating and supporting documents |
| Branch reach | 30 / 45 / 60 cm or a project drawing | Reach of each branch, stagger and routing constraints |
| Other requests | Source mentions 0.9 mm legs, pulling eyes and staggered fanout | Feasibility, protection, dimensions and quote: confirmation with BWNFiber |
The source lists 117 combinations of length, map label and jacket. Those combinations are inquiry options; they are not 117 verified part numbers or stocked items. A formal order code and revision must be assigned by BWNFiber — confirmation with BWNFiber.
Inputs for a comparable quotation
Send the mating MPO part number, panel or cassette drawing, LC destination schedule, fiber map, overall and branch lengths, jacket requirement, quantity and destination market. State the requested optical test method and acceptance limits. Ask for availability, MOQ, lead time and sample arrangements in the quotation; none is established by the source option table.
Why Source from BWNFiber
Start with a configuration review so that the drawing, quotation and acceptance requirements refer to the same assembly. Ask BWNFiber to confirm the connector BOM, fiber specification, dimensional tolerances and labeling schedule before an order is released.
Request optical test records that identify the agreed assembly or batch and the relevant fiber paths. The report should state the measured quantity, wavelength, reference method and pass/fail limits. IEC 61300-3-4 describes attenuation measurement procedures; citing it does not prove that this product has passed a test. Report availability and the actual inspection scope are confirmation with BWNFiber.
Compare the required mating assembly in the MPO trunk cable range. A related product listing is not proof of compatibility; use matching connector and channel drawings.
Need a Configuration Review or Sample?
Send your MPO mating interface, twelve LC destination ports, required lengths and quantity. Request a drawing review, written performance limits and a project quotation from BWNFiber. Sample availability and delivery terms require confirmation.
RFQ message: “Please review a proposed MPO-24/PC male to 12 × LC/UPC duplex OM3 aqua assembly. Attached are our mating connector details, 24-position map and LC port schedule. Required overall length: ; branch lengths: ; jacket requirement: ; quantity: ; destination: __. Please confirm the BOM, tolerances, test scope, sample availability and commercial terms.”