MPO Breakout & Harness Cable

MPO-16 OM4 to 16 LC Simplex Breakout Cable

Connect an OM4 MPO-16 distribution point to sixteen individual LC simplex terminations. Specify the branch destinations, connector interfaces and routing dimensions before requesting a quote.

MPO Breakout & Harness Cable

Hero

Connect an OM4 MPO-16 distribution point to sixteen individual LC simplex terminations. Specify the branch destinations, connector interfaces and routing dimensions before requesting a quote.

Product Overview

This MPO-16 OM4 to 16 LC simplex breakout cable is specified for installations that need each of sixteen fibers to terminate separately. The supplied configuration lists one female MPO-16 connector, sixteen LC/UPC simplex connectors and a violet OM4 jacket. It is intended for an approved Base-16 distribution layout with individually identified LC destinations.

Sixteen simplex connectors describe sixteen separate fiber terminations. They do not establish sixteen duplex links, a transceiver breakout mode or a transmission speed. Where the system uses paired transmit and receive fibers, the equipment documentation and approved position map determine the pairs.

The supplied file identifies the MPO end as PC. Keep that detail on hold until BWNFiber confirms the connector part number and mating-interface drawing. Do not substitute APC or assume that all multimode MPO-16 interfaces use the same polish. The MTP-16 connector reference documents a distinct connector and keying family; it does not establish the brand or compatibility of this BWNFiber assembly.

Key Features

  • One defined 16-fiber configuration for individual LC termination.
  • OM4 multimode fiber and violet jacket specified in the supplied material.
  • Separate LC/UPC simplex ends for a project-specific branch identification schedule.
  • A configuration request that records every MPO position and LC destination.
  • Overall length and branch lengths specified separately on the assembly drawing.

These are the proposed configuration attributes. Final construction, availability and performance are confirmation with BWNFiber.

Technical Specifications

FieldSupplied configuration / release requirement
AssemblyOne MPO-16 to 16 × LC simplex ends; confirm approved BOM
Fiber count16 fibers; confirm continuity of all positions
Fiber categoryOM4 multimode, 50/125 μm — confirmation with BWNFiber
MPO genderFemale / unpinned in source; verify the mating interface
MPO polishPC in source; connector part and end-face drawing required — confirmation with BWNFiber
LC interface16 × LC/UPC simplex in source — confirmation with BWNFiber
Jacket colorViolet in source; confirm against the supplied photograph and BOM
Trunk diameter3.0 mm in source — confirmation with BWNFiber
Overall lengthRequested range 1–50 m; available builds and measurement datum require confirmation
Branch lengthSource lists 30, 45 and 60 cm; approve individual branch lengths on drawing
Jacket choicesSource lists LSZH, OFNP and OFNR; exact construction and applicable documentation required
Optical performanceApproved maximum insertion loss and return loss, wavelength and test method required
EnvironmentTemperature, bend radius and tensile limits not supplied; confirmation with BWNFiber
ComplianceNo certification or compliance claim released from this draft

The source lists MPO insertion loss ≤0.60 dB, typical ≤0.35 dB and LC insertion loss ≤0.20 dB. These are unverified attachment values, not accepted limits for purchase or publication. Ask for the approved test specification identifying whether each value applies to a connector pair, a termination or the complete assembly. A typical value must not replace a guaranteed acceptance maximum.

Selection Guidance

Confirm the termination format

RequirementSelection consequence
Sixteen individual LC simplex destinationsReview this configuration and the numbered branch schedule
Eight paired LC duplex connectionsSelect a documented duplex assembly; do not silently treat this SKU as a duplex version
MPO-12 distribution interfaceSelect a matching interface or a separately engineered transition
MPO-to-MPO redistributionUse the MPO conversion cable range
Enclosed front-panel presentationCompare the breakout and cassette approaches before selecting the assembly

Approve the position map

Record the viewing direction, key orientation and pinning at the MPO interface. Assign each input position to its LC branch ID and destination port. Account for all sixteen positions once; mark any unused project destination explicitly. A Type A, B or C label alone is insufficient to approve the build.

For channel-level design, continue to the MPO polarity and channel design guide. The product drawing must remain specific to this assembly, including its revision and direction of view.

Measure the route and branches

Provide the path from the MPO connection to the breakout point and from that point to each LC destination. Specify the connector reference planes used for overall length, the longest and shortest branches, permitted tolerances and whether branches should be staggered. Confirm bend and strain limits from the approved cable construction. Do not add an arbitrary slack allowance without checking the cabinet route.

Check the application separately

A fiber count does not prove SR8, 400G or 800G compatibility. Supply the exact equipment and optical-module part numbers if the assembly connects to active optics. The optical interface, wavelength, supported breakout mode and complete transmit/receive map must all match. A passive harness routes fibers; it does not convert a transmission protocol.

Applications

Individual LC panel termination

Use this configuration as a candidate where an approved MPO-16 OM4 distribution path must terminate on separately identified LC panel positions. The branch schedule should follow panel labels and the service team’s identification convention.

Integration and acceptance setups

For a rack integration or test setup that requires separate access to each fiber, specify the branch lengths and inspection access around the actual fixture. Suitability for a particular test method or equipment port requires engineering confirmation; the assembly is not a loopback device.

Distributor configuration requests

Use one controlled BOM and drawing revision when collecting project requirements or repeat-order requests. Record the optical build separately from packaging and label artwork so a revised carton label does not conceal a changed fiber map.

Order Guide

Use the following request fields in place of a repeated list of assumed stocked SKUs.

RFQ fieldWhat to provide
ReferenceAttachment reference 4; final BWNFiber order code to be assigned
EndpointsMPO mating part / panel reference and sixteen LC destination IDs
Connector buildMPO-16 pinning, polish and keying; LC/UPC simplex construction
FiberOM4 and required jacket color
MappingControlled 16-position-to-branch schedule with drawing revision
LengthOverall datum, branch dimensions, tolerances and route constraints
JacketRequested fire/environment classification and destination project requirements
AcceptanceMaximum loss limits, test scope, wavelengths and report fields
CommercialQuantity, sample need, destination, required delivery date and packaging

The attachment lists these nominal overall lengths. They are request values, not a statement of inventory. Metres control; feet below are approximate, not alternative manufacturing tolerances.

MetresApproximate feet
13.28
1.54.92
26.56
39.84
516.40
722.97
1032.81
1549.21
2065.62
2582.02
3098.43
40131.23
50164.04

Do not release the proposed order-code pattern from the attachment as a catalog identifier until BWNFiber approves its syntax and option combinations. MOQ, production lead time, sample availability and pricing are confirmation with BWNFiber.

Customization and Quality Review

Requested construction options

The source mentions alternate branch lengths, 0.9 mm legs, staggered fanout, pulling eyes and OEM labels. Submit these as requests for feasibility review. Available combinations, mechanical protection and assembly dimensions are confirmation with BWNFiber. Jacket labels alone do not prove the product meets a project’s installation requirements.

Acceptance documents to request

Request a signed specification, connector BOM, dimensioned drawing, full continuity map and an example of the proposed optical test report. Confirm the report identifies the assembly and revision, fiber or branch ID, test wavelength, method, reference arrangement, limits and measured results. Agree the inspection and documentation scope before ordering a sample or production lot.

The attachment names IEC 61300-3-4 as a test-method reference and several interface or performance standards. Listing a standard is not evidence of compliance. BWNFiber must confirm the applicable parts and editions, test conditions and supporting records. Neither RoHS evidence nor a fire-rating document is included in the supplied material.

Related Products

FAQ

Request a Configuration Review

Are sixteen simplex ends the same as eight duplex connectors?

They contain the same number of fiber terminations, but the physical presentation and pairing differ. This request specifies individually terminated LC simplex ends; obtain a separate approved configuration for duplex housings or clips.

Can this connect to a conventional MPO-12 port?

Do not specify direct mating. Confirm the actual connector family and keying; a Base-12 transition requires its own documented hardware and mapping.

Is the female MPO interface sufficient to approve the connection?

No. Pinning is only one field. Verify the ferrule/interface family, key orientation, polish and mating component as well.

Is PC definitely the correct MPO polish?

PC is what the attachment states. The connector BOM and mating drawing remain confirmation with BWNFiber. Do not change the specification to APC solely because another supplier offers it.

Does OM4 mean the cable supports 800G SR8?

No. OM4 alone does not establish compatibility. Check the module-specific optical interface, supported breakout mode, mapping and channel budget.

Can Type B be selected by default?

No. Attach a complete position-to-branch map. The approved drawing must define the selected polarity label for this build.

What does the violet jacket establish?

It is the requested color in this configuration. Color alone does not verify fiber category or optical performance; use the BOM and test records.

Is the listed length measured to the breakout point?

The source does not define a sufficiently precise drawing datum. Specify the connector reference planes and branch lengths separately before order approval.

Are LSZH, OFNP and OFNR interchangeable?

Do not substitute one label for another. Select the documented construction required by the project and have its installation suitability checked. Availability and evidence are confirmation with BWNFiber.

Can the harness be polarity-switched in the field?

The source states it is not field-switchable. Do not plan a field change without a documented connector-specific procedure and engineering approval.

Will a test report be supplied for every branch?

That scope is not verified. Request a sample report and agree branch identification, limits, measured values and delivery scope with BWNFiber.

What is needed for a quotation?

Send endpoint references, the sixteen-branch map, dimensions, jacket requirements, quantity, destination and acceptance criteria. Identify missing fields so they can be resolved before an order is released.

Send your MPO-16 simplex harness requirements with the panel or equipment references, branch schedule, route dimensions and quantity. Ask BWNFiber to confirm the connector build, optical acceptance limits, available options and quotation scope against one drawing revision.

Image and Implementation Notes

  • No photographs generated or supplied in this package. Retain the existing template’s gallery positions.
  • Proposed main image filename: mpo-16f-om4-to-lc-simplex-breakout-cable.jpg
  • Proposed alt: MPO-16 OM4 breakout cable with sixteen individual LC simplex connectors and a violet jacket.
  • Apply this alt only after the actual image is checked; use an empty alt for purely decorative duplicates.
  • Preserve the reference template’s hero, gallery, detail panels, FAQ and related-product grid. Map this content into existing fields.
  • Breadcrumb: Home > Products > Data Center Solutions > MPO Cabling > MPO Breakout & Harness Cable > this product.
  • Use WebPage and BreadcrumbList for the review. Add Product data only after the product identity, image, SKU and visible claims are approved. No fabricated Offer, stock, price, review or rating. A product snippet requires a qualifying offer or review/rating property under Google’s current guidance.
  • H1 appears once. H2 sections contain H3 subsections; no H4 is necessary for this product’s depth.
Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.