Connect an MPO-12/APC female interface to twelve individual SC/APC terminations with this OS2 single-mode harness. The supplied configuration specifies 12 fibers and a yellow jacket. It is intended for matching single-mode patching infrastructure where the branch destinations are SC/APC, with the final pinning, fiber map and dimensions agreed before ordering.
Product Overview
This MPO 12F OS2 to SC APC breakout cable provides twelve separate fiber paths between a multi-fiber connector and individual panel ports. It is a passive routing assembly, not an optical power splitter. Twelve SC connectors describe twelve simplex terminations; they do not, by themselves, establish twelve duplex Ethernet channels.
Choose this configuration when the installed panel requires SC/APC and the MPO interface, fiber positions and end-to-end path have been checked. For a different branch connector, return to the MPO breakout and harness cable range rather than substituting the connector name on an order.
Key Features
- One MPO-12/APC female connector and twelve SC/APC simplex connectors in the supplied specification.
- OS2 single-mode fiber, nominal 9/125 μm, with a yellow jacket.
- Individually addressable branch destinations for SC/APC patching schedules.
- Configuration review based on the mating connector, panel layout and required fiber-position map.
- Separate overall-length and fanout-length fields to make the installation drawing unambiguous.
Technical Specifications
The identity fields below come from the supplied product material. They remain subject to an approved BWNFiber model datasheet; they are not independently tested results.
| Item | Supplied configuration / release requirement |
|---|---|
| Product family | MPO Breakout / Harness Cable |
| MPO end | MPO-12/APC female, unpinned; confirm the mating connector and key orientation |
| Branch end | 12 × SC/APC simplex |
| Fiber paths | 12; final position-to-branch schedule required |
| Fiber | OS2 single-mode, nominal 9/125 μm; exact fiber designation needs approval |
| Jacket color | Yellow |
| Overall length | Source lists 1–50 m; availability and measurement datum: confirmation with BWNFiber |
| Fanout length | Source lists 30 / 45 / 60 cm and a 30 cm default: confirmation with BWNFiber |
| Jacket options | Source lists LSZH, OFNP and OFNR; construction and applicable evidence: confirmation with BWNFiber |
| SC/APC optical limits | Source states IL ≤0.20 dB and RL ≥60 dB; test scope, conditions and acceptance limits: confirmation with BWNFiber |
| MPO and complete-path loss | Not established by the SC connector values; needs a separate approved test specification |
| Environmental and mechanical limits | Temperature, diameter, bend radius and tensile limits: confirmation with BWNFiber |
Do not treat the listed SC loss value as the loss of the complete MPO-to-SC path. Compare quotations using the same measured interfaces, wavelength, reference method and acceptance criteria.
Selection Guidance
Match the branch termination
| Installed destination | Selection decision |
|---|---|
| SC/APC panel | Consider this assembly after checking the MPO end and fiber map |
| SC/UPC panel | Specify a separately approved SC/UPC assembly; do not directly mate APC to UPC |
| LC panel or equipment port | Select the appropriate LC harness configuration |
| Another multi-fiber MPO endpoint | Review a trunk or conversion assembly instead |
APC and UPC mating surfaces are different. An adapter does not convert one polish into the other. See Fluke Networks’ APC connection guidance for the mating limitation.
Approve the twelve-fiber destination schedule
Record MPO fiber position, SC branch label and destination panel port for all twelve paths. Add connector viewing direction and key orientation to the drawing. Do not use a Type A, B or C label as a substitute for that schedule. The source describes a fixed assembly, not a field-switchable polarity product. Use the MPO polarity checklist to prepare the channel information for review.
Check equipment compatibility separately
This page makes no general DR4, PSM4 or data-rate compatibility claim. A matching MPO shell does not establish correct lane use or compatible branch ports. Confirm the exact optic, active positions, host breakout mode, downstream interface and optical budget before specifying an equipment connection. Cisco’s 400G transceiver data sheet illustrates why the exact module interface matters; it does not qualify this BWNFiber assembly.
Applications
- SC/APC distribution panels: terminate individual OS2 paths from an approved MPO-12 interface into identified panel positions.
- Single-mode cross-connects: prepare a defined branch schedule where several simplex destinations share one harness route.
- Enclosure integration: evaluate fanout reach, connector clearance and strain relief against the enclosure drawing before choosing leg lengths.
These are selection scenarios, not customer case studies or system-performance guarantees. For enclosure architecture, consult the cassette harness planning guide.
Order Guide
Configuration fields
| Field | Information to send |
|---|---|
| Interfaces | MPO-12/APC female to 12 × SC/APC; identify the mating MPO connector |
| Fiber map | Twelve position-to-label-to-port entries with viewing direction |
| Overall length | Metric value, measurement endpoints and tolerance |
| Branch dimensions | Fanout datum, shortest/longest leg, equal or staggered layout |
| Installation | Route, connector clearance, strain relief and required jacket classification |
| Quantity | Sample and production quantities, destination and required date |
| Acceptance | Optical test scope, wavelengths, limits, branch labels and required records |
The source lists the following metric lengths. These are request options pending confirmation, not a stock or lead-time commitment.
| Meters | Approximate feet | Meters | Approximate feet |
|---|---|---|---|
| 1 | 3.28 | 15 | 49.21 |
| 1.5 | 4.92 | 20 | 65.62 |
| 2 | 6.56 | 25 | 82.02 |
| 3 | 9.84 | 30 | 98.43 |
| 5 | 16.40 | 40 | 131.23 |
| 7 | 22.97 | 50 | 164.04 |
| 10 | 32.81 | — | — |
Metric dimensions control the request. Overall cable length and exposed fanout length must be shown separately. For an uneven port layout, attach the port spacing and proposed branch destinations instead of requesting “standard stagger.”
Custom requests
The source mentions 0.9 mm legs, staggered fanout, pulling eyes, OEM markings and custom lengths. Feasibility, dimensions, qualification evidence and availability are confirmation with BWNFiber. A requested option is not an approved manufacturing capability. Ask for the configuration drawing and quotation before using any proposed order-code pattern in purchasing systems.
Why Source from BWNFiber
Use the configuration review to resolve the complete assembly specification: connector identities, twelve-fiber map, route dimensions, jacket requirements and acceptance documents. The existing breakout assembly listing describes a broader range; its limits must not be transferred automatically to this exact configuration.
Quality control and acceptance documents
Request an approved drawing, bill of materials and representative test-report format. The optical record should identify the tested path, wavelength, reference method, insertion-loss limit and return-loss measurement scope. Include continuity, branch-label verification and end-face inspection criteria in the agreed acceptance plan. Inspection coverage and shipment-document availability are confirmation with BWNFiber.
The attachment names IEC, TIA, GR-326 and RoHS references without supporting reports or declarations. No conformity claim is made here. Require the applicable edition, scope, tested configuration and evidence before including compliance wording in a purchase specification. Jacket color is not evidence of a fire classification.
Specification disclaimer: The supplied values and options are for reference only, not a guarantee. The approved model datasheet, drawing and order specification must establish the applicable limits and configuration.
Request an SC/APC Configuration Review
Send BWNFiber the mating MPO connector details, twelve destination ports, overall and branch dimensions, required jacket, quantity and delivery destination. Ask for the proposed drawing, confirmed optical limits, available acceptance records and project quotation. Confirm sample availability, MOQ and lead time in the quotation.