MPO Breakout & Harness Cable

MPO-12 OS2 to FC/UPC Breakout Cable — 12 Fibers

This MPO-12 OS2 to FC breakout cable connects one MPO-12/APC female interface to twelve FC/UPC simplex ends. It is intended for single-mode equipment or distribution positions that require FC connections. Specify the destination of every branch, the mating interfaces and the installed route before requesting a quotation.

MPO Breakout & Harness Cable

Hero

This MPO-12 OS2 to FC breakout cable connects one MPO-12/APC female interface to twelve FC/UPC simplex ends. It is intended for single-mode equipment or distribution positions that require FC connections. Specify the destination of every branch, the mating interfaces and the installed route before requesting a quotation.

Product Overview

Use this configuration when all twelve fiber positions must be brought out to individually identified FC/UPC connections. The proposed assembly uses OS2 9/125 μm single-mode fiber and a yellow jacket. Its defining feature is the twelve-port FC termination layout; the equipment documentation must establish the optical service carried on each fiber.

The MPO side and FC sides have different polish types because they connect to different mating interfaces. APC and UPC must match at each physical connection. The cable does not convert a UPC receptacle into an APC receptacle, split optical power, or establish a supported Ethernet breakout mode.

For other connector families, start with the MPO breakout and harness range. For a complete MPO-to-MPO route, review the MPO trunk cable range.

Key Features

  • One MPO-12/APC female connector and twelve FC/UPC simplex terminations in the supplied configuration.
  • Twelve individually addressable fibers for FC-based single-mode equipment or distribution.
  • OS2 fiber and yellow jacket specified in the source record.
  • Branch identification and dimensional requirements captured together on the order drawing.
  • Length, jacket and optical acceptance requirements reviewed before a build is released.

Technical Specifications

ItemProposed configuration / confirmation required
AssemblyMPO-12 to 12 × FC simplex breakout
Active fibers12
MPO endMPO-12/APC, female / unpinned; confirm mating interface and key orientation
Branch ends12 × FC/UPC simplex; confirm equipment receptacles
FiberOS2 single-mode, 9/125 μm; specific fiber standard and manufacturer need confirmation
Jacket colorYellow
Overall lengthSource lists 1–50 m; available lengths and tolerances: confirmation with BWNFiber
Fanout lengthSource lists 30 / 45 / 60 cm; default, datum and availability: confirmation with BWNFiber
Jacket optionsSource lists LSZH / OFNP / OFNR; exact construction and supporting documentation: confirmation with BWNFiber
Fiber mappingSource lists Type A / B / C; use a position-to-branch drawing for this terminated assembly: confirmation with BWNFiber
Insertion loss and return lossLimits, test wavelengths, reference method and report scope: confirmation with BWNFiber
Cable / leg diameter; bend radiusconfirmation with BWNFiber
Operating / storage conditionsconfirmation with BWNFiber
Certification or conformityProduct-specific documentation and applicable editions: confirmation with BWNFiber

A standard number in a catalog is not a test result. The public family page cannot establish the loss grade or environmental rating of this particular assembly.

Selection Guidance

Match both mating interfaces

Record the MPO receptacle’s pin state, ferrule format, polish and key orientation. The proposed female MPO end is unpinned and needs a compatible pinned mating connector. At each branch, verify that the port accepts FC/UPC. Do not choose an FC/APC alternative solely because the trunk end is APC.

Keep all twelve destinations explicit

Twelve simplex ends mean twelve individual fiber paths. They are not twelve duplex links, and a duplex pairing must not be inferred from adjacent branch numbers. Record the twelve destination labels and their function, including any fibers deliberately reserved by the system designer.

Position-to-port record for the order drawing

Required fieldWhat to record
MPO positionPosition number and drawing viewing direction
FC branchUnique label, such as FC-01 through FC-12
DestinationEquipment identifier and actual port designation
Service roleTransmit, receive, test or reserved, as defined by equipment documentation
Mapping approvalDrawing revision and responsible engineering approver

This table defines the information required; it does not assign a pin map. A Type A, B or C label alone does not approve the equipment-to-equipment path. See the MPO channel polarity design workflow for complete channel review.

Check space at the FC ports

Allow access to the threaded FC coupling nuts, keep branch labels readable, and confirm that the fanout transition can be supported without pulling on the connectors. Supply port spacing, enclosure dimensions and cable-entry direction when requesting unequal branch lengths. The drawing must define overall-length and branch-length measurement points and tolerances.

Applications

Intended useAcceptance condition
Single-mode test equipment with FC/UPC receptaclesInstrument interfaces, wavelength range and reference-cord requirements confirmed
FC-terminated distribution inside an enclosureTwelve positions mapped, cable supported and connector access checked
Replacement of an existing MPO-to-FC harnessBoth mating interfaces, branch numbering, route and original drawing compared

The assembly is not specified here as a polarization-maintaining cable, a loopback, or an eight-fiber parallel-optic breakout. Those functions require different evidence and may require a different product.

Order Guide

Send the following fields with a drawing or port list. The source’s repeated option rows are consolidated here so that the ordered configuration is easier to review.

Order fieldSelection or information to supply
Product referenceRecord 21 — MPO-12/APC female to twelve FC/UPC simplex, OS2, yellow
Required length1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40 or 50 m listed in source; confirm availability
MappingRequested A/B/C designation plus the full twelve-position branch map
JacketRequested LSZH, OFNP or OFNR construction with project requirements
FanoutLength of each leg, common or staggered arrangement, measurement datums
Mechanical detailsCable and branch diameter, routing envelope and strain relief
LabelsFC destination labels, assembly identifier and drawing revision
AcceptanceContinuity map, loss limits, wavelengths and required report format
Commercial scopeQuantity, destination, sample request and required delivery date

Metric dimensions govern the drawing. For reference, 1 m ≈ 3.28 ft and 1.5 m ≈ 4.92 ft. Availability, MOQ, lead time and price require a quotation; the listed options do not establish stock status.

Custom configuration requests

The source mentions 0.9 mm legs, staggered fanout, pulling eyes, OEM print and custom lengths. Feasibility and supply scope for each request are confirmation with BWNFiber. State the installation constraint first; request a reviewed drawing before treating a proposed feature as an accepted order option. The suggested order-code pattern in the source is not a confirmed sellable part number.

Why Source from BWNFiber

A useful quotation should identify the exact assembly and the documents needed to accept it. Ask BWNFiber to confirm the connector BOM, twelve-position map, dimensions, approved materials and test scope against the same drawing revision. This gives purchasing and engineering a common reference when comparing the quotation with the installed FC port arrangement.

Quality control and test documentation

Request continuity results that associate each MPO position with its FC branch label. Agree insertion-loss limits separately from return-loss limits, with wavelength, reference method and pass/fail criteria. Confirm whether records are supplied per assembly and per fiber; inspection and report availability are confirmation with BWNFiber.

Keep standards references tied to their actual scope. FC and MPO interface standards describe connector interfaces; they do not prove this product’s conformity or optical performance. The IEC FC interface publication provides context, while Fluke’s APC connector guidance explains why the polish at a mating connection matters.

Need a Configuration Review or Sample?

Send your twelve FC destination labels, MPO mating-interface details, route length, fanout dimensions, required jacket, quantity and acceptance criteria. Ask for confirmation of the proposed assembly drawing, available documentation, sample feasibility and project quotation.

Request an MPO-to-FC configuration review

FAQ

Image and Implementation Notes

Does twelve FC simplex mean twelve duplex links?

No. It means twelve separate fiber terminations. The equipment plan determines any transmit/receive pairing; do not assume a pairing from the connector count alone.

Why is the MPO end APC while the FC ends are UPC?

They connect to separate interfaces. Match APC at the MPO connection and UPC at each FC connection. Different polish at opposite cable ends is not the same as mating APC directly to UPC.

Can this replace an FC/APC harness?

Not without reviewing every FC receptacle. This proposed configuration specifies FC/UPC, so an FC/APC requirement changes the branch interface and needs a separate configuration review.

How should the twelve FC ends be labeled?

Use unique branch identifiers tied to the MPO position map and destination-port list. Confirm label location and readability in the actual enclosure before approving the drawing.

Is Type B automatically correct for this cable?

No. The terminated map must match the two endpoints and any intermediate components. Provide the position-to-port drawing instead of relying on a polarity name alone.

Can an eight-fiber FC assembly replace this one?

Not when twelve paths are required. An eight-fiber alternative requires a revised active-position map, branch list and equipment review; it is not a length or jacket option of this configuration.

Can it be used with polarization-maintaining instruments?

The source specifies OS2 fiber, not a polarization-maintaining assembly. Instruments requiring axis alignment or extinction-ratio performance need a separately verified design.

Are 30 cm breakout legs standard?

The source proposes a 30 cm default and other lengths. Confirm the final leg dimensions, measurement points and tolerances on the drawing; current availability is confirmation with BWNFiber.

Is the cable plenum-rated because it is yellow or LSZH?

Neither color nor an LSZH description establishes a plenum rating. Request the exact cable construction and supporting documentation required for the installation location.

What should accompany the quotation?

Request the proposed drawing revision, connector BOM, fiber map, dimensional tolerances, acceptance criteria and available test-record scope. MOQ, sample availability and lead time must be stated in the quotation.

  • Product images generated: 0. Keep the reference template’s gallery positions; insert the user’s prepared product photographs during manual staging.
  • Image filename from source: mpo-12f-os2-to-fc-breakout-cable.jpg.
  • Proposed main-image alt, subject to checking the actual photograph: Yellow OS2 breakout cable with one MPO-12 APC female connector and twelve FC/UPC simplex ends.
  • Do not use the loopback template’s product images, part numbers, loss values, G.657A2 claim or loopback Schema for this SKU.
  • Breadcrumb: Home > Products > Data Center Solutions > MPO Cabling > MPO Breakout & Harness Cable > this product.
  • Schema: Product and BreadcrumbList only after final URL, actual product identity, image URLs and approved facts are confirmed. No fabricated Offer, price, availability, review, rating, SKU or GTIN. Quote-only product rich-result eligibility requires separate verification.
  • The editorial status and confirmation markers require resolution before publishing. No customer or engineer byline has been invented.
Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.