Hero
MPO-12/APC female to twelve LC/UPC simplex connectors. A 12-fiber OS2 configuration specified with G.657.A2 fiber, Type A mapping and a black LSZH jacket. Send your port schedule and routing dimensions for a configuration review.
Product Overview
The MPO 12F G657A2 LC simplex breakout cable is a proposed configuration for single-mode distribution panels with twelve individual LC connections and a project requirement for black LSZH cable. It combines an MPO-12/APC female interface with twelve LC/UPC simplex ends; fiber grade, jacket and mapping are specified together so procurement can identify the intended build.
The supplied product record describes this assembly as OS2, G.657.A2, Type A and black LSZH. confirmation with BWNFiber: approve the released BOM, jacket color and signed drawing before using these values as a purchasing specification. The source product name also contains “Yellow”; this draft resolves the wording in favor of its repeated black-jacket specification, pending confirmation.
Use the MPO breakout and harness range to compare other terminations. This configuration is for individual LC port allocation. Fiber count alone does not establish a transceiver breakout application, data rate or transmission distance.
Key Features
- One MPO-12/APC female interface and twelve separate LC/UPC simplex terminations, as specified in the supplied record.
- Twelve active single-mode fibers; G.657.A2 is the requested fiber designation.
- Black LSZH construction is retained as a configuration requirement, without a plenum or riser rating claim.
- Type A is the stated assembly mapping. A numbered fiber-to-leg drawing is required for endpoint approval.
- Individual LC legs support a port-by-port schedule; record each leg label and destination before ordering.
- Overall length and fanout dimensions are reviewed separately so a long trunk does not conceal branches that cannot reach their assigned ports.
Technical Specifications
Configuration record
| Parameter | Supplied configuration / release requirement |
|---|---|
| Source reference | 18; source index, not a confirmed production SKU |
| MPO interface | MPO-12/APC female; mating pin state and key orientation require drawing review |
| Branch interface | 12 × LC/UPC simplex |
| Active fiber count | 12 |
| Optical designation | OS2 single-mode; requested fiber grade G.657.A2 |
| Jacket | Black LSZH; contradictory “Yellow” wording requires resolution |
| Mapping | Type A in source; approve all twelve position-to-leg assignments |
| Overall length | Source lists 1–50 m; availability and measurement tolerance require confirmation |
| Fanout length | Source lists 30 / 45 / 60 cm; applicability and measurement datum require confirmation |
| Cable / leg diameter | confirmation with BWNFiber; no released dimensions supplied |
| Installation / operating bend radius | confirmation with BWNFiber for the finished assembly |
| Insertion loss / return loss | confirmation with BWNFiber: selected grade, wavelength, reference method and acceptance limits |
| Fire classification / declarations | confirmation with BWNFiber; LSZH is not evidence of OFNP or OFNR qualification |
Documentation for approval
Request the drawing revision, material identification and applicable fiber optic testing requirements together. Record IL and RL separately, including wavelength, connector interface, reference setup, acceptance limit and the result for each applicable path. Do not transfer general limits from another product family to this configuration.
ITU-T G.657 describes bending-loss-insensitive single-mode fiber and cable characteristics. Its fiber designation does not replace the finished assembly’s installation instructions. The attachment lists IEC/TIA references and RoHS but supplies no supporting declarations; compliance wording is therefore withheld pending BWNFiber confirmation.
Selection Guidance
Match this build to the port schedule
| Your requirement | Selection decision | Evidence to check |
|---|---|---|
| Twelve individual LC single-mode ports and black LSZH requirement | Evaluate this configuration | Twelve-leg drawing, material specification and interface approval |
| Six mechanically paired LC connections | Evaluate an LC duplex configuration | Pairing, Tx/Rx schedule and clip orientation |
| Eight active paths for a parallel optical interface | Evaluate an eight-fiber assembly separately | Module part numbers and active-position map |
| Plenum or riser qualification | Request a separately documented construction | Applicable cable listing and approved installation requirement |
| Yellow jacket or a different mapping | Request a different configuration | Revised BOM and product identity |
Approve the path, then the cable length
- Record both endpoints and any intervening adapter, cassette or trunk. Distinguish an MPO panel connection from a module receptacle.
- Check MPO pin state, APC mating interface and key orientation; identify the LC/UPC endpoints independently.
- Put every MPO position and LC leg identifier on one drawing. Type A at the cable level does not by itself approve the complete channel polarity method.
- Measure the route, service allowance and required fanout reach. Define overall-length reference points and branch-length tolerances in the purchase drawing.
- Agree the finished-cable bend limits, environmental conditions and optical acceptance criteria before approving the quantity.
Release checkpoint
If the equipment map, material requirement and drawing disagree, keep the order on technical hold. Resolve the discrepancy through a revised configuration record rather than allowing a substitute under the same product name.
For channel planning, consult the MPO polarity channel-design workflow and obtain an approved drawing for this specific assembly.
Applications
Individual-port single-mode distribution
Evaluate this build where a single MPO interface must be allocated to twelve separately identified LC ports and the project BOM specifies black LSZH and G.657.A2. The installer needs a leg schedule, not an assumed six-pair arrangement.
Panel routing with a specified fiber grade
G.657.A2 can be a requested fiber attribute in a constrained routing design. Check the assembly’s cable diameter, fanout housing, boot clearance and permitted bend radius before accepting the route. “Bend-insensitive” does not mean unrestricted bending.
Controlled replacement or repeat purchasing
A replacement order should identify the original drawing revision, interface, mapping, jacket and length. Color is an identification aid; it does not prove the optical type. These are selection scenarios, not claims of completed BWNFiber customer installations.
Order Guide
Fixed configuration and length schedule
Keep MPO/APC female, twelve LC/UPC simplex ends, Type A mapping, G.657.A2 and black LSZH together in the requested configuration. The following lengths come from the attachment and are confirmation with BWNFiber for availability; they are not stock statements. Feet are approximate conversions of metric values, not separate ordering sizes.
| Requested length (m) | Approximate feet | Jacket for this configuration |
|---|---|---|
| 1 | 3.28 | Black LSZH |
| 1.5 | 4.92 | Black LSZH |
| 2 | 6.56 | Black LSZH |
| 3 | 9.84 | Black LSZH |
| 5 | 16.40 | Black LSZH |
| 7 | 22.97 | Black LSZH |
| 10 | 32.81 | Black LSZH |
| 15 | 49.21 | Black LSZH |
| 20 | 65.62 | Black LSZH |
| 25 | 82.02 | Black LSZH |
| 30 | 98.43 | Black LSZH |
| 40 | 131.23 | Black LSZH |
| 50 | 164.04 | Black LSZH |
Changes requiring a separate review
Submit custom length, staggered fanout, leg diameter, pulling-eye, label or packaging requests with a drawing. confirmation with BWNFiber: feasibility, minimum order, price, lead time, sample availability and documentation scope. OFNP, OFNR, yellow jacket and Type B are not selectable options under this fixed description; they require a separately approved build.
The attachment’s proposed code BWN-BO-M12APCF-12LCSX-OS2-G657A2-BLK-LSZH-A-{LEN} is a draft naming pattern. Obtain the official orderable part number from BWNFiber before issuing a purchase order.
Why Source from BWNFiber
Ask for a configuration-specific evidence package
Use the quotation review to establish what BWNFiber will supply for this exact assembly: the approved drawing, component identification, optical acceptance criteria, label schedule and packing requirements. These records allow purchasing and engineering to compare the same configuration instead of comparing unlike jacket grades or unconfirmed loss classes.
confirmation with BWNFiber: the fiber optic manufacturing and inspection steps applicable to this SKU, test-record availability, traceability method and any requested third-party qualification. No factory audit, batch report or certificate was supplied with this product record.
Browse the existing fanout assembly series for the broader catalog context. Confirm whether this black-jacket build is a variant of that series before assigning a separate product URL.
Need a Configuration Review or Sample?
Send BWNFiber your endpoint references, twelve-leg port schedule, overall length, fanout dimensions, black LSZH requirement, quantity and destination. Include required acceptance documents and the requested delivery date.
Ask for written confirmation of the final part number, drawing revision, price, lead time and sample arrangement. Use the inquiry form on this page for the configuration review. For an alternative connectivity architecture, start with MPO cabling families.