Specify this MPO-12 APC male to LC simplex OS2 cable when the approved connection requires a pinned multi-fiber end, twelve individual LC/UPC terminations and a blue PVC jacket. Confirm the mating connector, fiber-position schedule and installation requirements before ordering. The assembly described here comes from supplied product information; final construction and availability are confirmation with BWNFiber.
Product Overview
This configuration distributes twelve single-mode fiber paths from one MPO-12/APC male connector to twelve LC/UPC simplex connectors. Individual LC ends allow each fiber to be assigned to a labeled destination. The blue jacket is a project identification attribute; it does not establish fiber type, fire rating or equipment compatibility.
The supplied document identifies OS2 fiber and blue PVC, but also includes the word “Yellow” in its product name. This draft uses blue PVC as the intended configuration because the filename, core keyword and specification agree on blue. The approved drawing and physical sample must resolve the conflicting color description before release.
For alternative branch formats, review the current fanout product range and confirm the selected construction.
Use the MPO breakout and harness category to compare assembly families. This page is for checking the pinned, individual-LC configuration against a specific connection schedule.
Key Features
- One MPO-12/APC male connector, identified as pinned in the supplied material.
- Twelve LC/UPC simplex ends for individually assigned fiber destinations.
- OS2 single-mode, 9/125 μm fiber listed in the source; the exact fiber specification requires approval.
- Blue PVC jacket requested for this build, with color identification kept separate from installation compliance.
- Separate ordering fields for total length, branch geometry, labeling and the approved fiber map.
Technical Specifications
Specification notice: These are source-listed attributes and open approval fields, not independently verified test results or promises of stock.
| Parameter | Configuration / evidence boundary |
|---|---|
| Source reference | 19; document reference, not a verified commercial SKU |
| Multi-fiber interface | MPO-12/APC, male / pinned |
| Branch interface | 12 × LC/UPC simplex |
| Active fibers | 12 listed; confirm each path on the approved drawing |
| Fiber | OS2 single-mode, 9/125 μm; grade and supplier record: confirmation with BWNFiber |
| Jacket | Blue PVC intended; conflicting “Yellow” wording must be resolved |
| Overall length choices in source | 1, 1.5, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40, 50 m |
| Fanout choices in source | 30 / 45 / 60 cm; stated default 30 cm; reference points and tolerance: confirmation with BWNFiber |
| Polarity choices in source | Type A / B / C; approve the actual position-to-LC mapping for the selected assembly |
| Cable and branch diameters | confirmation with BWNFiber; do not infer them from another harness |
| Optical acceptance | Maximum insertion loss, minimum return loss, wavelength, method and measurement scope: confirmation with BWNFiber |
| Mechanical conditions | Bend radius, pulling load and operating/storage temperature: confirmation with BWNFiber |
| Documentation | Product drawing, fiber/jacket records and test-report availability: confirmation with BWNFiber |
The source names TIA/EIA-568.3-D, IEC 61754-7, IEC 61754-20, IEC 61753-1 and RoHS. These references do not establish compliance for this assembly. Applicable editions, document scope and supporting evidence are confirmation with BWNFiber. No certification or numerical optical limit is claimed here.
Selection Guidance
Check the mating connector, not the adapter name
The source’s “unpinned adapter” wording is not a sufficient mating specification. Record the connector presented at the far side of the adapter or equipment port. Confirm its pin state, polish and key orientation against the proposed cable. A pinned MPO end requires the appropriate unpinned mating connector; do not force a pinned-to-pinned connection.
The APC designation applies to the MPO end; UPC applies to the LC ends. Those are different endpoints of the assembly. At each mating connection, confirm the correct interface and polish. A connector fitting into an adapter is not proof that the optical interface is correct.
Assign all twelve individual destinations
Provide one row for each LC end, labeled L1 through L12. For every row, record the MPO position, LC label, destination panel/port and continuity acceptance result. The drawing must show the viewing direction and key orientation used to number the MPO positions. Do not fill a presumed straight-through map solely from the words Type A, B or C.
| Record for every path | Required input | Release condition |
|---|---|---|
| MPO position | Number from the approved end-view drawing | Orientation and pin state identified |
| LC identity | Unique label L1–L12 | One destination per intended fiber path |
| Destination | Panel, port or equipment identifier | Matches the project connection schedule |
| Continuity | Required mapping and verification record | No missing, duplicated or unintended destination |
| Optical result | Agreed limit, wavelength and test scope | Matches the approved acceptance schedule |
The channel polarity design guide covers the wider channel review. Keep the approved map with the order instead of relying on a polarity letter in the purchase description.
Separate color, material and installation requirements
Blue identifies the requested jacket color. PVC identifies the stated material. Neither entry by itself proves a plenum or riser classification. If the route requires specific fire or installation documentation, ask for the exact jacket designation and supporting record. LSZH, OFNP and OFNR appear as replacement requests in the source; they are not confirmed interchangeable variants of the blue PVC build.
Compare adjacent configurations
| Configuration under review | Decisive difference | Selection consequence |
|---|---|---|
| This blue PVC configuration | Pinned MPO end and twelve individual LC ends | Requires compatible unpinned mating hardware and approval of the jacket |
| Yellow OS2 simplex source, reference 17 | Unpinned MPO end in its supplied description | Do not substitute on color preference alone; check the opposite pin state |
| G657A2 / black LSZH source, reference 18 | Different stated fiber/jacket and unpinned MPO end | Treat as a separate BOM proposal until engineering confirms the relationship |
| Duplex LC harness | LC ends organized into pairs | Check port pairing rather than assuming individual destinations |
The neighboring documents are comparison inputs, not proof that those products are published or available. If one approved OS2 simplex family page can serve these configurations clearly, this content should become its pinned blue-PVC variant rather than a competing search page.
Applications
- Single-mode distribution panels: evaluate when the panel presents a compatible unpinned MPO connection and twelve labeled LC destinations are required.
- Integrator installation schedules: evaluate when jacket color is controlled separately from connector identity and fiber type in the project BOM.
- Distributor repeat orders: reference the approved drawing revision, pin state and labeling schedule to distinguish this build from an unpinned yellow assembly.
These are selection scenarios, not completed BWNFiber customer projects. This assembly is not automatically an 8-active-fiber DR4 or PSM4 breakout. Do not infer Ethernet speed, reach or host breakout support from the twelve-fiber count.
Order Guide
Submit one configuration schedule
| Order field | What to send |
|---|---|
| Interfaces | MPO-12/APC male to 12 × LC/UPC simplex, plus the mating equipment or connector identity |
| Fiber and jacket | OS2 requirement, blue PVC request and applicable installation documentation |
| Mapping | Twelve-row position/LC/destination schedule and drawing orientation |
| Dimensions | Total length, branch lengths, transition location, measurement points and tolerances |
| Identification | Cable ID, L1–L12 labels, package labels and drawing revision |
| Acceptance | Required inspection, continuity, polarity and optical reporting scope |
| Commercial scope | Quantity, delivery destination, required date and any sample requirement |
Use meters as the order unit. One meter is approximately 3.28 feet; five meters is approximately 16.40 feet. Rounded feet in the original table should not be treated as alternate cut lengths. Specify how overall length is measured and whether a staggered fanout changes that measurement.
The source lists custom lengths, 0.9 mm legs, staggered fanout and pulling eyes. Feasibility, construction limits and commercial terms are confirmation with BWNFiber. The proposed order-code pattern in the attachment has not been validated as an issued BWNFiber SKU; request the confirmed part number with the drawing.
Why Source from BWNFiber
Define the evidence needed to approve this build
Ask BWNFiber to identify the proposed construction, any deviations from your requirement and the documents available for approval. A usable quotation should tie the connector identity, jacket, dimensions, map and acceptance criteria to the same configuration revision.
Agree the fiber optic testing scope
Request continuity and polarity verification for the specified paths, connector inspection requirements, and insertion-loss/return-loss records at the agreed wavelengths. Specify whether a limit covers a connector pair, the complete harness or the installed channel. Those scopes must not be mixed when comparing quotations. Actual inspection coverage, methods, instruments, traceability and supplied records are confirmation with BWNFiber.
Fiber optic manufacturing claims such as inspection of every unit, in-house production or guaranteed report delivery require supporting evidence for this order. The supplied attachment alone does not establish those claims. Sample availability, OEM printing, packaging, MOQ and delivery timing also require quotation confirmation.
Need a Configuration Review or Sample?
Send your pinned OS2 harness schedule with the mating connector identity, twelve LC destinations, blue PVC requirement, route dimensions and quantity. Ask for the proposed drawing, unresolved technical fields, available acceptance records and quotation terms. If the mating pin state is unknown, identify that uncertainty before approving the assembly.