MPO Breakout & Harness Cable

MPO 12 Fiber OM4 to LC Uniboot Breakout Cable

Specify a 12-fiber OM4 MPO to six LC uniboot duplex assembly. Review port pairing, branch lengths and jacket requirements with BWNFiber.

MPO Breakout & Harness Cable

This MPO 12 fiber OM4 to LC uniboot breakout cable connects one MPO-12/PC female end to six LC/UPC uniboot duplex ends. Specify it for twelve fiber paths grouped into six duplex terminations, with each pair assigned to its destination port.

Product Overview

The supplied configuration uses OM4 50/125 μm multimode fiber and a violet jacket. Each LC uniboot groups two fibers through one boot. That construction changes cable handling behind the connector; it does not by itself reduce the spacing of the LC adapter ports or prove compatibility with a populated panel.

Use this item when a defined MPO distribution connection must terminate in six LC duplex pairs. Approve the mating interfaces and the full position-to-port schedule before ordering. A twelve-fiber assembly is not automatically a four-lane SR4 breakout: the actual fiber pairing, optics and host breakout support must agree.

For a different branch format, start from the MPO breakout and harness selection page. The existing multi-configuration fan-out listing covers broader requests and does not establish the exact uniboot build described here.

Key Features

  • One MPO-12/PC female connector and six LC/UPC uniboot duplex terminations in the supplied product description.
  • Twelve OM4 multimode fiber paths, grouped into six duplex endpoints.
  • Violet jacket for identification; color alone does not establish the fiber specification.
  • Factory-selected polarity; the source does not offer field polarity switching for this item.
  • Metric lengths listed from 1 to 50 m; confirm the selected build and dimensional tolerances.
  • Branch-length and labeling requirements can be recorded against each destination port before quotation.

Technical Specifications

Specification notice: These supplied details are subject to approval of the exact production specification. The BOM, connector drawing and exact order configuration are confirmation with BWNFiber before release.

ParameterSupplied configuration / release condition
Document reference6; document serial, not a verified catalog SKU
MPO endMPO-12, PC, female / unpinned; component identity and end view: confirmation with BWNFiber
LC ends6 × LC/UPC uniboot duplex; twelve fiber terminations in total
FiberOM4 multimode, 50/125 μm
AppearanceViolet jacket; connector housing colors not specified
Overall length1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m listed in source
Fanout length30 / 45 / 60 cm listed; 30 cm described as default. Measurement datum and availability: confirmation with BWNFiber
PolarityType A / B / C requests listed. Actual MPO-position-to-LC-pair mapping required
Jacket requestLSZH / OFNP / OFNR listed. Exact cable construction and supporting documents: confirmation with BWNFiber
Insertion and return lossGuaranteed limits, test wavelength, reference method and measurement scope: confirmation with BWNFiber
Mechanical limitsBranch diameter, bend radius, tensile limit, boot dimensions and temperature range: confirmation with BWNFiber
Standards / declarationsSource lists TIA/EIA-568.3-D, IEC 61754-7, IEC 61754-20, IEC 61753-1 and RoHS. Applicable editions, scope and evidence: confirmation with BWNFiber

Selection Guidance

Approve six pair destinations

Provide a port schedule for pair 1 through pair 6. For every pair, record the two MPO positions, both LC positions and the destination duplex port. State the viewing direction and key orientation on the MPO end-view drawing. Do not substitute a Type A/B/C label for this completed map.

Pair identifierMPO positionsLC A/B assignmentDestination duplex portLeg length datum
P1To be approvedTo be approvedBuyer inputBuyer input
P2To be approvedTo be approvedBuyer inputBuyer input
P3To be approvedTo be approvedBuyer inputBuyer input
P4To be approvedTo be approvedBuyer inputBuyer input
P5To be approvedTo be approvedBuyer inputBuyer input
P6To be approvedTo be approvedBuyer inputBuyer input

This is an order-review worksheet, not a wiring diagram. No pin map is inferred from the product name. Use the channel polarity review workflow for the complete connection, including trunks, adapters and cassettes.

Check the uniboot body against the actual panel

Check connector width, latch access, boot exit direction and space for the branch bend. If a single LC ferrule must move independently to another destination, this paired format may be unsuitable. A proposed alternative should identify the required single-fiber routing rather than simply replacing the product name.

The SENKO LC uniboot description illustrates a duplex construction using one round cable. It does not establish that this BWNFiber item uses SENKO hardware or supports the same field operations. The exact connector component and supported handling procedure remain confirmation with BWNFiber.

Separate passive distribution from an SR4 request

Six duplex terminations describe the physical assembly. They do not mean six active Ethernet breakout channels from one SR4 transceiver. For an SR4 application, identify the optics, enabled host mode, occupied MPO positions and required transmit-to-receive pairs before choosing the harness. The LC boot style alone does not decide optical compatibility.

Cisco’s breakout reference provides equipment-specific breakout examples. Treat it as application context, not certification of this cable. No speed or reach guarantee is made for this item.

Define branch length and optical acceptance separately

Measure the overall assembly and each leg from agreed drawing datums. Keep service slack within the approved bend radius and avoid loading a connector when routing the branches. A longer fanout may solve reach to a port but still obstruct latch access or cable management.

Documents to approve with the sample

Request the end-view drawing, pair schedule, dimensions, exact jacket identification and proposed test record. Agree maximum insertion loss, minimum return loss where applicable, wavelength, reference method, and whether limits cover a connection or a complete fiber path. The attachment references IEC 61300-3-4; the applicable method and report availability are confirmation with BWNFiber. Factory acceptance and the installed channel budget are separate checks.

Applications

Connection taskReason to evaluate this itemCheck before approval
MPO distribution to six duplex LC portsTwelve fibers are grouped into six paired destinationsEvery destination and MPO position appears on the approved schedule
Panel or cassette integrationUniboot branches may suit paired cable routingActual internal space, end-face compatibility, pinning and branch routing
Replacement of a paired harnessA controlled drawing supports like-for-like reviewExisting map, dimensions and connector component match; color alone is insufficient

These are selection scenarios, not customer case studies. For an enclosure-versus-direct-cable decision, consult the breakout cable and cassette comparison.

Order Guide

Submit reference 6 with the required length, jacket, quantity and six-pair destination schedule. The source lists 117 request combinations: three polarity labels × three jacket choices × thirteen metric lengths. These combinations are not a stock or manufacturability statement.

Buyer fieldRequired input
ConnectionMating equipment or cassette part numbers; pinning and polish at the MPO interface
PairingApproved P1–P6 map, including LC A/B positions and destination labels
DimensionsOverall metric length, each leg length, tolerances and measurement points
JacketRequested designation, destination market and installation requirement
AcceptanceOptical limits and conditions, continuity/polarity checks and records requested
Commercial requestQuantity per build, destination, sample requirement and requested delivery date

Use meters as the controlling unit. For example, 1 m is approximately 3.28 ft and 2 m is approximately 6.56 ft; rounded feet in the original schedule are not exact alternative order lengths. The accompanying CSV retains all 117 source-listed combinations with corrected approximate conversions.

Custom lengths, staggered legs, pulling eyes, mixed branch formats and 0.9 mm construction require an approved drawing: confirmation with BWNFiber. The source’s suggested order-code pattern is an internal proposal, not an established SKU. Do not order from that pattern without catalog confirmation.

Why Source from BWNFiber

Ask BWNFiber to return a quotation that identifies the proposed build and any exceptions against the same pair schedule. This gives purchasing, engineering and receiving teams one reference for sample approval and repeat orders.

The source mentions factory termination, inspection, OEM printing and IL/RL records. Inspection coverage, reporting entitlement, customization capability, MOQ and lead time for this exact assembly are confirmation with BWNFiber. Request the supporting records before accepting them as order conditions.

Need a Configuration Review or Sample?

Send the six-pair configuration request with reference 6, endpoint part numbers, P1–P6 schedule, metric dimensions, jacket, quantities and required acceptance records. Ask for the proposed BOM, open exceptions and sample terms before approving a build.

FAQ

MPO 12 Fiber OM4 to LC Uniboot Breakout Cable FAQ

How many LC connections does this assembly provide?

It has six duplex LC terminations containing twelve fibers. Six paired terminations are not twelve duplex ports.

Does uniboot mean the panel ports are closer together?

No. Confirm the adapter spacing and connector dimensions. One boot changes cable organization; it does not establish a smaller LC port footprint.

Can the two fibers of a pair go to separate ports?

The supplied format groups each pair in one uniboot duplex connector. Independent single-fiber destinations require a different approved branch construction.

Can I use all six pairs on an SR4 port?

Do not infer this from the connector count. SR4 uses four optical lanes in each direction; the cable map, optics and enabled host mode must match.

Is Type B enough to approve the six-pair map?

No. Require the actual MPO-position-to-LC assignment, viewing direction and key orientation, and check the complete channel.

Can polarity be switched in the field?

The supplied document states that this SKU is not field polarity-switchable. Do not transfer switching features from another uniboot product.

Does the female MPO end fit any cassette?

Check the mating connector behind the adapter, including pinning, polish and keying. The word cassette does not establish those details.

Is the 30 cm fanout included in the overall length?

The source does not define the dimensional datums clearly enough. Approve an overall-length and leg-length drawing; the interpretation is confirmation with BWNFiber.

Are all listed jacket and length combinations available?

They are source-listed request options. Availability, compliance documentation and build restrictions are confirmation with BWNFiber for the selected combination.

What evidence should accompany a repeat order?

Reference the approved BOM and drawing revision, pair labels, dimensions and agreed acceptance records. Require any component substitution to be declared before approval.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.