MPO Breakout & Harness Cable

MPO 12 Fiber OM4 to LC Duplex Breakout Cable

Specify an MPO 12 fiber OM4 to LC duplex breakout cable with six duplex terminations. Review the fiber map, branch layout and requirements for your quote.

MPO Breakout & Harness Cable

Product Overview

Specification disclaimer: This configuration is subject to an approved product datasheet, drawing and order specification. Availability, compliance evidence, test limits and commercial terms are confirmation with BWNFiber.

This MPO 12 fiber OM4 to LC duplex breakout cable connects one MPO-12/PC female interface to six LC/UPC duplex terminations. It is intended for a twelve-fiber multimode distribution path where every fiber must be presented at an LC endpoint. Confirm the endpoint drawing and fiber assignment before ordering; connector count alone does not establish application compatibility.

The supplied configuration specifies OM4 50/125 μm fiber and a violet jacket. Use the approved fiber specification to confirm the grade. Jacket color identifies the assembly but does not prove its optical performance or suitability for a particular transceiver.

Key Features

  • One MPO-12 interface and six LC duplex terminations for a twelve-fiber path.
  • Female, unpinned MPO end, with PC finish as specified in the supplied configuration.
  • LC/UPC duplex branch ends for separately identified pairs.
  • OM4 multimode configuration for a matching multimode cabling plant.
  • Order definition by fiber map, overall length, branch layout and installation requirements.

Technical Specifications

The configuration below is taken from the supplied product material. Product engineering must approve it before release. Unverified availability and performance are marked confirmation with BWNFiber.

ParameterConfiguration / approval requirement
Product reference7 — internal reference, not a confirmed manufacturer part number
MPO endMPO-12/PC female (unpinned); confirm connector drawing and mating pin state
LC end6 × LC/UPC duplex; 12 fiber terminations
FiberOM4 multimode, 50/125 μm, as specified in source material
Jacket colorViolet, as specified in source material
PolarityType A, B or C requested in source; actual MPO-position-to-LC map is confirmation with BWNFiber
Overall lengthSource lists 1–50 m; availability and custom lengths are confirmation with BWNFiber
Fanout lengthSource lists 30 / 45 / 60 cm and a 30 cm default; approved geometry is confirmation with BWNFiber
Cable dimensionsSource lists 3.0 mm trunk and 2.0 mm duplex legs; construction is confirmation with BWNFiber
Jacket optionsSource lists LSZH, OFNP and OFNR; availability and supporting documentation are confirmation with BWNFiber
Insertion / return lossLimits, wavelengths, reference method and test records are confirmation with BWNFiber
ComplianceApplicable standards, revisions and product-specific declarations are confirmation with BWNFiber

Confirm the connector interface

State the gender and finish at both ends in the purchase specification. An unpinned MPO end requires a correctly matched pinned mating interface. Do not change PC to APC, or replace a generic MPO connector with a branded connector description, without an approved component specification. Confirm key orientation with the port or adapter drawing.

Approve the fiber map

A polarity letter is an ordering aid, not a complete channel drawing. Ask for the MPO position assigned to each LC connector, the two fibers in every duplex pair, the LC A/B orientation and the label at each branch. Check the complete path, including any cassette, adapter and patch cord. Do not infer a pin assignment from the phrase “six duplex.”

Application Fit

Intended taskFit decisionInformation required
Present twelve OM4 fibers on an LC patching fieldCandidate configurationMPO interface, all twelve fiber positions and LC pair assignments
Connect to a cassette’s exposed MPO interfaceConditionalCassette part number, interface drawing and internal mapping
Organize six duplex circuits in a distribution areaConditionalEnd-to-end pair continuity, routing and branch identification
Connect a four-lane SR4 breakoutDo not select by this description aloneExact module SKU, populated fiber positions, supported breakout mode and a matching assembly
Connect an OS2 singlemode pathDifferent fiber configuration requiredSinglemode product specification and connector requirements

A twelve-fiber harness is not an optical splitter. It routes individual fibers; it does not divide optical power or convert a data rate. Do not assume a cassette has a usable MPO connection on the side shown in a rack drawing. Identify the actual accessible interface before selecting the harness.

For alternatives, start with the MPO breakout and harness range. For a multi-fiber connection without LC fanout, review the MPO patch cord category.

Order Guide

Define one approved configuration

  1. Provide the two endpoint part numbers or clear interface drawings.
  2. Confirm twelve required fiber paths and six duplex pair assignments.
  3. Attach the requested MPO-to-LC map, key orientation and branch labels.
  4. Specify overall length and fanout geometry from agreed drawing reference points.
  5. State the installation’s jacket requirement and documentation needed for acceptance.
  6. Send quantity, destination, requested delivery date and any label or packaging requirements.
  7. Approve the supplier’s drawing revision and optical acceptance specification before production.

Length schedule

Use metres as the order unit. Feet below are approximate references, rounded to two decimal places; they are not alternative manufacturing tolerances. Listed lengths are source options, with availability confirmation with BWNFiber.

MetresApproximate feetMetresApproximate feet
13.281032.81
1.54.921549.21
26.562065.62
39.842582.02
516.403098.43
722.9740131.23
50164.04——

Define the end-to-end measurement on the drawing. Separately identify the fanout transition, each branch length and any staggering needed to reach the port row. Leave routing slack according to the equipment layout and the approved cable handling specification; do not use an assumed bend-radius value.

Jacket and customization requests

Provide the installation requirement rather than choosing by color or a general low-smoke description. LSZH, OFNP and OFNR are not interchangeable labels. Ask which documented cable construction meets the project’s required classification. For markets outside the United States, submit the local installation and documentation requirements with the RFQ.

The source lists custom lengths, labels and packaging. These are requests for feasibility review: confirmation with BWNFiber. Do not treat every polarity × length × jacket combination as a stocked SKU. Field polarity adjustment is not established for this configuration; approve the required map at ordering.

Quality and Acceptance Review

Ask for a product-specific test specification before accepting a quotation. It should define the measured paths, relevant wavelengths, insertion-loss limits, any required return-loss limits, reference arrangement and report identification. Standards named in source material do not demonstrate that this build has passed a test.

For the sample review, agree on:

  • Continuity and position-to-position mapping for all twelve fibers.
  • Duplex pair and branch-label agreement with the approved drawing.
  • Connector end-face inspection criteria and the cleaning procedure.
  • Measured optical results tied to an identifiable assembly or batch.
  • Length, branch layout and cable construction against the accepted BOM.
  • Cable classification evidence and any declarations required for the destination.

BWNFiber’s available reports, test limits, certifications, sample process, MOQ and lead time are confirmation with BWNFiber. Request documents for this configuration rather than relying on a general company claim. No transmission distance or data-rate guarantee is made by this cable description.

Request a Configuration Quote

Send BWNFiber the endpoint drawing, twelve-fiber map, length, branch layout, jacket requirement, quantity and destination. Include required acceptance records and the delivery date you need. Ask for a quoted configuration, drawing revision and confirmed scope of supply.

Submit the configuration for review. For channel planning questions, consult the MPO polarity and channel design resource and validate the final map against the actual equipment.

FAQ

MPO 12 Fiber OM4 to LC Duplex Breakout Cable FAQ

Why does this configuration have six LC duplex terminations?

Six duplex terminations provide twelve fiber connections. Confirm their assigned positions on the MPO interface; the count does not specify the map.

Is this a four-channel SR4 module breakout cable?

Do not approve it from this description. Check the exact module’s interface, fiber positions and supported host breakout mode, then select the assembly specified for that path.

Can it connect to any OM4 cassette?

No. The cassette must expose the required mating interface and have a compatible internal map. Send its part number and drawing for review.

Does female mean that the MPO connector has guide pins?

No. The supplied female configuration is unpinned. Verify the corresponding mating interface and key orientation before ordering.

Is Type B always the correct polarity?

No. Select the map for the whole channel. The approved drawing must identify each MPO position and each LC pair, including any intermediate components.

Can polarity be changed in the field?

The source describes a factory-fixed assembly. Do not assume field-switchable polarity or gender; order the required configuration after drawing approval.

Does a violet jacket verify OM4 performance?

No. Confirm the fiber grade in the product documentation and the required optical acceptance records. Color is an identification aid.

Can the same optical build use any jacket option?

Availability and classification depend on the approved cable construction. The LSZH, OFNP and OFNR options in the source remain confirmation with BWNFiber.

Are all listed lengths available from stock?

Stock is not established. Request availability, MOQ and lead time for the selected configuration and quantity. Custom lengths require separate confirmation.

Can I substitute a uniboot version?

Treat it as a separate mechanical configuration. Confirm connector housing, branch geometry and service access. The source’s serial 6 reference is not a verified live product link.

Which insertion-loss value should be on the order?

Use the value BWNFiber confirms for the selected build, wavelength and test method. This draft does not supply an unverified numerical limit.

What should a repeat order reference?

Reference the approved part number, drawing and BOM revision, fiber map, labels and acceptance criteria. Confirm that no component or construction changes affect the approved configuration.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.