Specify an MPO 12 fiber OM4 male to LC simplex breakout cable. Check pinning, branch mapping, length and jacket before requesting a configuration quote.

MPO Breakout & Harness Cable

This MPO 12 fiber OM4 male to LC simplex breakout cable connects one pinned MPO-12/PC interface to twelve individual LC/UPC connectors. The supplied configuration uses violet OM4 multimode cable. Select it for a documented twelve-fiber fanout where the mating MPO connector is unpinned and each LC termination has an assigned destination.

Product Overview

The twelve simplex branches let an installer identify and route individual fiber paths. They do not arrive as six mechanically paired LC duplex connectors. If the receiving equipment uses duplex ports, specify the required pairing, connector spacing and retention arrangement before approving this build.

This page describes the male, twelve-fiber OM4 configuration. For other fiber counts, connector arrangements or fiber types, use the MPO breakout and harness cable range.

Specification disclaimer: The supplied document establishes the proposed product identity, not approved production limits. Final BOM, dimensions, optical acceptance criteria and available options: confirmation with BWNFiber.

Key Features

  • One MPO-12/PC male connector, with alignment pins, to 12 × LC/UPC simplex connectors.
  • Twelve OM4 50/125 μm fiber paths; violet jacket specified in the supplied configuration.
  • Individual LC terminations for a drawing-controlled branch-to-port schedule.
  • Factory-selected polarity; field polarity switching is not offered in the supplied description.
  • Source-listed metric lengths from 1 to 50 m, subject to configuration confirmation.
  • One controlled order schedule for polarity, length, jacket and branch layout.

Technical Specifications

ParameterSupplied configuration or approval requirement
Document reference9; source-document number, not a verified manufacturer SKU
Product familyMPO breakout / harness cable
End AMPO-12/PC, male / pinned
End B12 × LC/UPC simplex
Fiber count and type12 fibers; OM4 multimode, 50/125 μm
Jacket colorViolet
Cable diameter3.0 mm listed; final construction and tolerance: confirmation with BWNFiber
Overall length requests1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m
Branch length requests30 / 45 / 60 cm listed; no default approved by this draft
Branch constructionSimplex; diameter, bend radius and retention detail: confirmation with BWNFiber
Polarity requestsType A / B / C listed; actual MPO-position-to-LC-label map requires approval
Jacket requestsLSZH / OFNP / OFNR listed; availability and installation documentation: confirmation with BWNFiber
Optical acceptanceMaximum insertion loss, minimum return loss, wavelength, reference method and measurement scope: confirmation with BWNFiber
Mechanical/environmental limitsBend radius, pull limit, temperature and mating durability: confirmation with BWNFiber
Standards and declarationsApplicable standards, editions, scope and evidence for this build: confirmation with BWNFiber

Selection Guidance

Check the connector behind the adapter

The male MPO end must mate with a compatible female MPO connector. Identify that connector even when it sits behind a panel adapter or inside a cassette. The adapter name alone does not establish pinning, end-face polish or key orientation. Do not mate two pinned connectors or combine incompatible end-face geometries.

Fluke Networks explains MPO pinning and fiber polarity. Use the actual endpoint documentation to approve a connection; the reference does not certify this assembly for a particular transceiver.

Specify twelve individual destinations

On the drawing, identify the MPO end-view direction, key orientation and positions 1–12. Assign a unique LC branch label and destination to each position. If two branches form a transmit/receive pair, record that pair explicitly. A count of twelve fibers is not a claim of twelve duplex links.

Build being comparedPhysical terminationBuyer decision
This configurationPinned MPO-12 to twelve LC simplex connectorsChoose when individual LC routing and male MPO mating are required
Six-duplex arrangementTwelve fibers organized into six LC pairsSpecify a separate duplex build when clips, pairing or port spacing require it
Eight-active-fiber SR4 breakoutApplication-specific fiber population and branch pairingApprove module, host breakout mode and lane map separately

These are configuration distinctions, not confirmation that every alternative is available from BWNFiber. A passive harness routes optical paths; it does not convert a protocol or guarantee a data rate.

If the required assembly type is unclear, compare the MPO cable types and connection roles before specifying this item.

Approve the complete polarity map

Type A, B or C alone cannot identify every branch destination after cassettes and trunks are added. Use the MPO polarity checklist for the complete channel record. Request the selected assembly’s position map and verify transmit-to-receive continuity against the endpoint plan.

Define dimensions and acceptance before quoting

State where overall length starts and ends, whether branch lengths are equal or staggered, and the required tolerances. Include the breakout transition and installed routing space. A listed overall length does not establish the reach of the longest branch or a permitted installation bend radius.

Evidence required for order release

Request the approved drawing revision, BOM, branch-label schedule, jacket identification and acceptance plan. Agree whether loss limits cover a mated connection or the complete assembly. Specify test wavelengths, reference method, end-face inspection criteria and which per-fiber records must accompany the order. Available testing and reporting scope: confirmation with BWNFiber.

Applications

Selection scenarioRequired approval
Compatible female MPO cassette interface to individual LC portsCassette connector pinning, polish, fiber map and branch reach
Twelve-fiber OM4 distribution with separate LC destinationsLabels 1–12 linked to the destination schedule
Panel-side transition to equipment with paired transmit/receive portsCorrect branch pairing, mechanical fit, channel budget and equipment documentation

These are potential applications, not customer case studies. Do not select this male connector for a pinned equipment interface. OM4 fiber and violet color alone do not prove a speed, distance or host compatibility.

Order Guide

Keep the twelve-fiber OM4 identity, male MPO-12/PC end and twelve LC/UPC simplex ends fixed for this item. Submit one line per requested configuration.

Order fieldInformation to provide
IdentityDocument 9 and approved product/BOM revision
Mating interfaceEndpoint part number, female MPO pinning, polish and key orientation
Fiber mappingMPO end view, LC branch labels and destination ports
PolarityRequested Type A / B / C plus approved position map
Overall lengthSource-listed metric length, measurement points and tolerance
FanoutBranch length, equal/staggered layout and transition position
JacketRequested designation, installation location and destination requirements
AcceptanceLoss limits, test scope, inspection requirements and records
Commercial inputsQuantity per build, sample request, delivery destination and required date

The source lists 117 combinations: three polarities × three jackets × thirteen lengths. These are quotation candidates, not verified stock or approval of every combination. Custom lengths, 0.9 mm legs, pulling eyes, labels and packaging requests require a drawing review: confirmation with BWNFiber. MOQ, price and lead time also require a quotation.

Use meters as the controlling dimension. For example, 1 m is approximately 3.28 ft and 1.5 m is approximately 4.92 ft. Rounded feet in the original table must not become a second manufacturing dimension.

Why Source from BWNFiber

Ask BWNFiber to quote against the same drawing and branch schedule used by your installation and receiving teams. Request written exceptions where the proposed build differs from the requested pinning, mapping, jacket or acceptance criteria. This creates a clear basis for comparing a sample with the production order.

Factory inspection coverage, traceability, report availability, OEM capability and jacket compliance are not established by the supplied draft: confirmation with BWNFiber. No unsupported certification, delivery or performance promise is included here.

Need a Configuration Review or Sample?

Request a configuration review with reference 9, the mating interface, twelve LC destinations, polarity drawing, overall and branch lengths, jacket, quantity and delivery destination. Ask for a quotation identifying the proposed configuration, exceptions and available verification documents.

FAQ

MPO 12 Fiber OM4 Male to LC Simplex Breakout Cable FAQ

Why does this configuration use a male MPO connector?

It is specified for mating with a compatible female MPO connector. Check the connector behind a panel adapter or cassette; do not approve pinning from the adapter label alone.

Does twelve simplex mean twelve duplex links?

No. Each simplex connector terminates one fiber. Conventional two-fiber duplex links need two assigned fibers per link, with correct transmit/receive mapping and mechanical pairing.

Can I replace six LC duplex connectors with these branches?

Only after checking branch pairing, port spacing and retention. Twelve individual connectors do not automatically provide the same handling arrangement as six duplex pairs.

Is this automatically a 40G or 100G SR4 breakout?

No. Confirm the exact optics, active positions, pinning, host mode and lane pairing. The twelve-fiber assembly name is not an SR4 application approval.

Can polarity be changed in the field?

The source specifies factory-selected polarity. It does not establish a field-switchable connector. Approve the map before ordering.

Is a Type A, B or C label enough to place the order?

Include the end-view direction and position-to-branch map as well. The complete channel may contain components that change the path assignment.

Is the fanout always 30 cm?

The original lists a 30 cm default and 30 / 45 / 60 cm options. This draft treats them as requests pending an approved drawing: confirmation with BWNFiber.

Can I order any of the three jacket designations?

They are source-listed options, not verified certification or availability. Submit the installation requirements and request documentation for the exact offered cable: confirmation with BWNFiber.

Which optical test limits apply?

No verified limits are supplied for this exact build. Agree maximum insertion loss, minimum return loss, wavelength, reference method and measurement scope before acceptance.

Is female MPO supplied under the same configuration?

Changing pinning changes the specified build. Request a separately identified configuration and review its mating interface; availability is confirmation with BWNFiber.

What should receiving inspection compare?

Compare the label and drawing revision, connector pinning, branch IDs, dimensions, jacket marking and agreed per-fiber records with the purchase order.

What information helps resolve a quotation quickly?

Provide the endpoint part number, branch destination schedule, polarity map, dimensions, jacket requirement, quantities and acceptance documents. Ask the quotation to state unresolved items explicitly.