MPO Breakout & Harness Cable

MPO 12F OM4 Armored to LC Simplex Breakout Cable

An MPO 12F OM4 armored to LC simplex breakout cable connects one MPO-12 interface to twelve individually terminated LC legs. The supplied configuration specifies a female PC MPO end, LC/UPC simplex ends and a violet armored trunk. Confirm the fiber map, protected section and jacket requirement before ordering.

MPO Breakout & Harness Cable

Hero

An MPO 12F OM4 armored to LC simplex breakout cable connects one MPO-12 interface to twelve individually terminated LC legs. The supplied configuration specifies a female PC MPO end, LC/UPC simplex ends and a violet armored trunk. Confirm the fiber map, protected section and jacket requirement before ordering.

Product Overview

This configuration is intended for buyers specifying an OM4 harness with individual LC terminations and an armored trunk. The twelve LC simplex connectors provide separate fiber endpoints; they do not by themselves define duplex port pairs, transmit/receive assignments or supported Ethernet breakout modes.

The supplied build lists twelve OM4 50/125 μm fibers, one MPO-12/PC female connector and twelve LC/UPC simplex connectors. Treat these details as a configuration for drawing review. confirmation with BWNFiber:the production BOM and connector terminology must match the approved drawing before this configuration is released.

Use the MPO breakout and harness range to compare other termination formats. For this product, the ordering decision is narrower: can the selected armor construction, LC leg arrangement and optical map satisfy the actual route and endpoint requirements?

Key Features

  • One MPO-12 connection to twelve LC simplex terminations.
  • OM4 multimode fiber, with violet jacket specified in the source configuration.
  • Armor specified for the trunk; coverage at the fanout and individual legs must be shown on the drawing.
  • Individual leg identification to be agreed against the destination port schedule.
  • Fixed ordered mapping; no field polarity-switching capability is claimed.
  • Overall and fanout lengths selected independently, with measurement datums agreed before production.

confirmation with BWNFiber:all construction and supply details above against the current approved product specification. Armor material, cable diameter and mechanical ratings are not established by the supplied document.

Technical Specifications

ParameterSource configuration / ordering requirement
Product familyMPO breakout / harness cable
Fiber count12 fibers
Fiber gradeOM4 multimode, 50/125 μm
Trunk connectorMPO-12/PC, female; confirm the exact connector part and mating interface
Branch connectors12 × LC/UPC simplex
Jacket colorViolet
Armor coverageArmored trunk; boundary and individual leg protection require a drawing
Overall lengthSource lists 1–50 m; availability and tolerances require confirmation
Fanout lengthSource lists 30 / 45 / 60 cm; no default is assumed without approval
MappingSource lists Type A / B / C; use a numbered MPO-position-to-LC-leg drawing
JacketSource lists LSZH / OFNP / OFNR; approve the exact cable construction and supporting documentation
Optical acceptanceInsertion loss, return loss, wavelength, reference method and limits: confirmation with BWNFiber
Mechanical acceptanceArmor material, outside diameter, bend radius, tensile and crush limits: confirmation with BWNFiber
EnvironmentIndoor/outdoor suitability, temperature and moisture/UV protection: confirmation with BWNFiber
Compliance documentsApplicable standards, editions, cable classification and RoHS evidence: confirmation with BWNFiber

The attachment’s list of IEC/TIA references does not establish certification or conformity for this assembly. Request the applicable document and its scope instead of treating a standards list as proof.

Selection Guidance

Confirm twelve individual fiber destinations

Prepare a port schedule with twelve rows. Each row should identify the MPO fiber position, the viewing direction used on the drawing, the LC leg label and its destination. Add transmit/receive pairing only where the connected equipment requires it. The labels “12 fibers,” “12 simplex” and “6 duplex pairs” describe different aspects of an assembly; they are not interchangeable ordering instructions.

Compare the physical builds

RequirementThis proposed buildAlternative to review
Twelve separately routed LC endpointsTwelve simplex LC terminationsA paired LC format if the destination requires fixed pairs
Armored main cable routeTrunk armor specified; limits pendingUnarmored harness if route protection already meets the project requirement
Eight active fibers for a specified moduleDo not infer compatibility from the connector nameA module-specific harness with approved lane mapping
Connection between MPO panelsBranch ends are LC, not MPOAn MPO-to-MPO assembly from the appropriate range

These alternatives are selection categories, not additional stock or certification claims.

Define the armor boundary

Specify where the armored section starts and stops, the fanout body position, the unsupported leg length and the routing space at each LC port. A protected trunk does not establish protection for exposed branches. Ask for the construction drawing, cable diameter, installation bend radius and pull method before approving a confined route.

For general construction choices, consult the armored MPO specification guide. Keep the final values on the build drawing for this assembly. Armor alone does not establish outdoor, water-blocking, rodent-resistant or direct-burial suitability.

Match the endpoints before choosing polarity

Confirm the mating connector, pin arrangement, key orientation, ferrule/end-face specification and equipment port map. Do not change PC to APC or assume a connector brand from a generic MPO description. Consult the channel polarity design workflow when the full link map is unresolved.

Applications

Project situationSuitability decision
Equipment room route with twelve separately identified LC fiber endpointsReview leg reach, connector clearance and the approved fiber map
Indoor tray route with a specified mechanical protection requirementCompare the required limits with the confirmed armored construction
Maintenance area where individual fibers need tracingApprove durable leg labels and their relationship to the port schedule
Outdoor route, direct burial or repeated moving-cable serviceHold selection until construction-specific evidence establishes suitability

This page does not assign a universal 40G or 100G application. Link operation depends on the equipment interfaces, lane assignments, fiber path and loss budget.

Order Guide

Build the RFQ in six steps

  1. Identify both endpoints, including module or panel references and mating connectors.
  2. Supply the twelve-row fiber map and LC destination labels.
  3. Define the main route and required armor coverage, including the fanout transition.
  4. Set overall length, individual leg lengths, measurement datums and tolerances.
  5. State the destination market, installation location and required cable classification documentation.
  6. Agree optical acceptance, labeling, packaging, quantity and delivery requirements before accepting the quotation.

Length selection

Overall length listed in the sourceApproximate feet
1 m3.28 ft
1.5 m4.92 ft
2 m6.56 ft
3 m9.84 ft
5 m16.40 ft
7 m22.97 ft
10 m32.81 ft
15 m49.21 ft
20 m65.62 ft
25 m82.02 ft
30 m98.43 ft
40 m131.23 ft
50 m164.04 ft

Metric dimensions control the drawing; feet are rounded references. The source’s repeated polarity/jacket/length rows have been consolidated here. A combination in a source table is not evidence of stock availability or an approved SKU.

Drawing and customization requests

Ask BWNFiber to review staggered legs, alternate fanout lengths, pulling protection, labels and packaging against the route. confirmation with BWNFiber:custom lengths, 0.9 mm legs, pulling eyes, OEM printing and the proposed order-code format in the attachment are not approved capabilities in this draft.

Do not attach a pulling accessory to connector legs without an approved load path. Request the permitted pulling arrangement and tensile limit for the actual assembly.

Quality and Acceptance

Specify the acceptance evidence before ordering: the approved BOM and drawing revision, continuity and mapping records for all twelve fibers, connector inspection criteria, insertion-loss results at the agreed wavelengths and return-loss requirements where applicable. Ask for traceability between the assembly label and its test record. confirmation with BWNFiber:which records BWNFiber supplies, their limits, test methods and delivery format.

Armor does not establish an insertion-loss value. Bend, stress, routing and assembly quality can affect optical performance; evaluate the completed cable under agreed conditions. Do not reuse acceptance values from a different connector grade or from the general harness family page.

For incoming inspection, compare the received connector count, labels, measured dimensions and drawing revision before connecting the cable. Inspect and clean the optical interfaces using the appropriate procedure, then verify the required mapping and link acceptance. Record any mismatch against the purchase specification rather than accepting a color match as proof of compliance.

Why Discuss This Build with BWNFiber?

A useful quotation should resolve this assembly’s twelve endpoints, armor boundary and acceptance criteria in one configuration record. Send the proposed build and ask BWNFiber to confirm supported options, documentation, price, MOQ and lead time for your quantity. No fixed delivery promise, production capacity or certification is asserted here.

FAQ

Request an Assembly Review

Are twelve LC simplex connectors the same as twelve duplex ports?

No. Twelve simplex connectors provide twelve individual fiber terminations. Duplex pair assignments, if needed, must be shown on the equipment port map.

Is every branch armored?

The source specifies trunk armor. It does not establish armored LC legs. confirmation with BWNFiber:the protected length and fanout transition on the assembly drawing.

Can this replace an eight-fiber SR4 harness?

Do not approve it solely by fiber grade or connector appearance. Check the module interface and the occupied fiber positions, then compare the complete fiber map.

Is this an outdoor cable?

Outdoor suitability is unconfirmed. Armor alone does not specify water protection, UV performance or operating environment.

Which MPO gender and polish should I order?

The supplied configuration states female PC. Confirm the mating connector and the exact part specification; do not substitute another polish or pin arrangement without engineering review.

Is Type A, B or C enough to define the order?

Use the requested polarity designation together with a numbered drawing. State the viewing direction and the corresponding LC label for each MPO position.

Does armor guarantee the same insertion loss as an unarmored cable?

No such guarantee is supported. Confirm the acceptance limit and test the completed assembly using the agreed conditions.

Is a 30 cm fanout always supplied?

The attachment calls it a default and also lists other lengths. confirmation with BWNFiber:the selected fanout dimensions and tolerance on the quotation and drawing.

Are all three jacket options interchangeable?

Do not assume so. Select the construction for the installation requirement and request documentation for that exact cable. confirmation with BWNFiber:availability and classification evidence.

Can the cable include a pulling eye?

Request a review of the accessory, attachment point, route clearance and permitted load. Availability and suitability need confirmation before ordering.

Can I order a custom overall length?

The source lists project lengths as a request option. Send the measurement datums, tolerance and routing drawing for confirmation; no universal custom-length capability is promised.

What should accompany a repeat order?

Quote the approved assembly identifier, drawing revision, connector parts, fiber map, lengths, jacket construction, acceptance criteria and packaging specification. Reconfirm any changed option.

Send your endpoint references, twelve-fiber port schedule, overall and fanout lengths, armor requirement, destination market and quantity. Ask for the confirmed BOM, drawing, acceptance plan and quotation before approving this configuration.

Request a configuration review or compare the harness product range.

Image and Schema Handoff

  • No product images generated or edited; existing photo slots remain reserved.
  • Proposed filename, only if the prepared photograph matches: mpo-12f-om4-armored-to-lc-simplex-breakout-cable.jpg
  • Proposed alt, after visual verification: Violet OM4 armored trunk with one MPO connector and twelve LC simplex legs.
  • Use the existing product template. Put the summary in its summary field, specifications and order guidance in its main body, and questions in its FAQ field.
  • Breadcrumb: Home → Products → Data Center Solutions → MPO Cabling → MPO Breakout & Harness Cable → this product.
  • Product markup may describe verified product facts after review. Do not invent SKU, GTIN, price, stock, reviews or ratings. An RFQ-only Product node without an offer/review/rating does not establish Google product-snippet eligibility.
  • Review BreadcrumbList against the final canonical URL. No Article or HowTo markup is needed for this product page. Do not promise FAQ rich results.
Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.