MPO Breakout & Harness Cable

MPO 12F OM3 to LC Uniboot Breakout Cable

Specify a 12-fiber OM3 MPO-to-LC uniboot harness with six duplex ends. Check the branch map, length and jacket before requesting a BWNFiber quote.

MPO Breakout & Harness Cable

Connect one MPO-12/PC female interface to six LC/UPC uniboot duplex ends with this 12-fiber OM3 assembly. Specify it for a mapped connection between an OM3 MPO path and six duplex LC positions. Confirm the endpoint interfaces, fiber map and branch routing before requesting a quote.

Product Overview

The MPO 12F OM3 to LC uniboot breakout cable groups twelve optical fibers into six duplex branches. The supplied configuration uses OM3 50/125 μm multimode fiber and an aqua jacket. Each uniboot end combines a duplex LC pair within a shared boot construction; the actual boot dimensions and cable construction must be checked against the panel drawing.

Use this configuration when all twelve paths are needed at six duplex positions. The cable does not convert an optical protocol or create six independent transceiver channels by itself. A cassette must have the correct mating interface and internal mapping; the word “cassette” alone does not establish compatibility.

For other fiber counts or branch types, start with the MPO breakout and harness selection page. For the broader assembly range, visit MPO cabling.

Key Features

  • One MPO-12/PC female connector and six LC/UPC uniboot duplex ends in the supplied design.
  • Twelve OM3 multimode fibers, allocated as six duplex pairs.
  • Aqua jacket for identification; color alone does not verify fiber performance.
  • Source-listed lengths from 1 to 50 m, with branch-length requests recorded separately.
  • Factory-selected fiber mapping; no field polarity change is offered by the supplied product description.
  • A configuration record links the connector arrangement, branch labels, routing dimensions and acceptance requirements.

Technical Specifications

Specification status: Product identity is taken from the supplied file. Availability, limits and build details require the approved BWNFiber specification. Items marked confirmation with BWNFiber remain open before order release.

ParameterSupplied configuration / required confirmation
Document reference10; a document identifier, not a verified manufacturer part number
Product familyMPO breakout / harness cable
MPO endMPO-12, PC, female / unpinned
LC ends6 × LC/UPC uniboot duplex
Fiber population12 fibers / 6 duplex pairs; exact position-to-pair mapping: confirmation with BWNFiber
Fiber typeOM3 multimode, 50/125 μm
Jacket colorAqua
Source-listed overall lengths1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m
Overall-length datumConnector reference planes, tolerance and equal/staggered branch measurement: confirmation with BWNFiber
Fanout lengths30 / 45 / 60 cm listed; default, tolerance and measurement points: confirmation with BWNFiber
Jacket requestsLSZH / OFNP / OFNR listed; exact cable construction, availability and documentation: confirmation with BWNFiber
Polarity requestsType A / B / C listed; approve an end-view drawing and complete fiber map
Optical acceptanceMaximum insertion loss, minimum return loss, wavelength, reference method and measurement scope: confirmation with BWNFiber
Mechanical limitsBranch diameter, boot dimensions, bend radius, tensile limit and temperature limits: confirmation with BWNFiber
Standards / declarationsApplicable editions and exact product coverage, including source-listed IEC/TIA references and RoHS: confirmation with BWNFiber

Selection Guidance

Check the six duplex landing positions

Record the panel or equipment model, LC adapter spacing, neighboring connector population and cable-management route. Uniboot describes the boot and cable arrangement; it does not establish a smaller LC mating pitch or guarantee more panel ports. Confirm latch access with adjacent ports occupied, then check the bend radius and service slack against the approved construction.

Separate fiber distribution from SR4 operation

A twelve-path harness feeding six duplex positions and an eight-active-fiber SR4 breakout perform different connection tasks. Do not substitute one on fiber count or connector appearance alone. Submit the module part numbers, host breakout setting and intended port assignments for engineering review.

Cisco’s QSFP module data sheet documents module-specific parallel interfaces and breakout use. It does not establish compatibility, speed or reach for this BWNFiber assembly.

Approve the map, not only the polarity letter

Request an MPO end view with viewing direction, key orientation and numbered positions. Map each position to the two LC sides of each labeled duplex branch. Check pinning and polish on the connector behind the mating adapter. A Type A/B/C label does not replace this map, and an uniboot housing does not imply field polarity switching.

Use the MPO channel polarity design guide for the full channel review. For a cassette connection, compare the cassette harness mapping guide.

Branch schedule for drawing approval

Branch labelMPO positionsLC side A destinationLC side B destinationRoute length
B1Assign on approved mapEnter portEnter portEnter requirement
B2Assign on approved mapEnter portEnter portEnter requirement
B3Assign on approved mapEnter portEnter portEnter requirement
B4Assign on approved mapEnter portEnter portEnter requirement
B5Assign on approved mapEnter portEnter portEnter requirement
B6Assign on approved mapEnter portEnter portEnter requirement

This is a blank approval schedule, not a proposed pinout. All twelve optical positions must appear once in the approved map, with no omissions or unintended duplicates.

Set the acceptance requirements

Ask for fiber optic testing requirements to be written into the quotation: continuity, polarity, connector end-face inspection and agreed optical-loss measurements. Define the wavelength, reference method and whether a limit applies to one mated connector pair or the entire assembly. Testing scope, limits, reporting and traceability supplied by BWNFiber: confirmation with BWNFiber.

Applications

Connection taskWhy this configuration may fitCheck before approval
MPO panel to six duplex LC positionsTwelve paths are presented as six paired branchesPanel interfaces, pinning, polish and pair map
OM3 cassette distributionA compatible MPO interface can route to the required LC pairsCassette internal wiring and occupied positions
Dense LC patching areaShared-boot ends may simplify the local cable arrangementActual branch construction, access and bending space

These are selection scenarios, not customer case studies. No speed, distance or equipment compatibility is promised from the cable name.

Order Guide

Keep the connector arrangement, OM3 fiber and six uniboot duplex ends fixed when requesting this item. Treat changes to LC construction or fiber grade as a separate configuration review.

Order fieldInformation to send
ReferenceDocument 10 and approved drawing revision
Endpoint interfacesMPO mating connector and six LC destination models
Fiber mapRequested Type A / B / C plus the approved position-to-branch schedule
Overall lengthMetric length and connector reference points
Branch geometryEqual or staggered branches, fanout datum and required lengths
JacketRequested material/rating, installation environment and destination market
AcceptanceAgreed limits, methods and required records
Commercial detailsQuantity by configuration, sample request, delivery destination and required date

The source lists 117 request combinations: 13 overall lengths × 3 polarity labels × 3 jacket requests. They are retained in the separate order matrix for review, without repeating the complete product name in every row. This is not a stock or availability statement. Metric length controls: 1 m ≈ 3.28 ft, 1.5 m ≈ 4.92 ft and 2 m ≈ 6.56 ft.

Custom lengths, 0.9 mm legs, staggered branches, pulling eyes, labels, packaging, MOQ and lead time: confirmation with BWNFiber. Do not use a pulling eye unless it is included in the approved assembly drawing and installation instructions.

Why Source from BWNFiber?

Ask BWNFiber to quote the six-pair connection against one agreed drawing, branch schedule and acceptance record. This gives purchasing, installation and receiving teams a common configuration reference, including any exceptions to the request.

The supplied material mentions termination, inspection, OEM printing and optical records. The corresponding fiber optic manufacturing process, inspection coverage and documents for this exact item remain confirmation with BWNFiber. Request evidence tied to the selected build rather than relying on a generic capability statement.

FAQ

Request a Configuration Quote

Is this six duplex ends or twelve separate LC connectors?

The supplied configuration has six LC uniboot duplex ends carrying twelve fibers. It is not specified as twelve independently routed simplex LC ends.

Does uniboot reduce the LC port pitch?

Do not assume it does. Verify the connector drawing and panel spacing; a shared boot does not establish a different LC mating interface.

Is it interchangeable with an OM3 standard-duplex harness?

Check branch construction, boot envelope, latch access and routing. Matching fiber count and grade alone does not establish physical interchangeability.

Can it be ordered as an OM4 version on this page?

This page covers the supplied OM3 configuration. Request a separately confirmed OM4 build and specification rather than treating fiber grade as an unverified substitution.

Is this a direct SR4 breakout cord?

It is specified here for twelve-path distribution to six duplex positions. Direct SR4 operation requires the correct active-position map and approved equipment configuration; do not approve it from this product name alone.

Can polarity be changed in the field?

No field polarity switching is offered in the supplied description. Approve the map before manufacture; the exact LC connector mechanism also requires confirmation.

Is 30 cm the confirmed fanout default?

The source names 30 cm as a default and lists 45 and 60 cm alternatives. The approved default, measurement points and tolerance are confirmation with BWNFiber.

Can LSZH replace an OFNP requirement?

Do not treat the labels as interchangeable. Submit the installation requirement and request documentation for the exact jacket construction; suitability is confirmation with BWNFiber.

Which optical-loss values apply?

No verified numerical acceptance limit was supplied. Maximum loss, return-loss minimum, wavelengths and reporting scope are confirmation with BWNFiber before order approval.

What should accompany a quote request?

Send reference 10, endpoint models, the six-branch schedule, requested length, jacket, quantity and acceptance requirements. Include the destination and required date so commercial terms can be confirmed.

Send your six-pair connection requirements to BWNFiber. Include the MPO interface, six LC destinations, fiber map, routing dimensions and quantities. Request the proposed specification, drawing and available sample or test documentation before approving the build.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.