Connect one MPO-12/PC female interface to six LC/UPC uniboot duplex ends with this 12-fiber OM3 assembly. Specify it for a mapped connection between an OM3 MPO path and six duplex LC positions. Confirm the endpoint interfaces, fiber map and branch routing before requesting a quote.
Product Overview
The MPO 12F OM3 to LC uniboot breakout cable groups twelve optical fibers into six duplex branches. The supplied configuration uses OM3 50/125 μm multimode fiber and an aqua jacket. Each uniboot end combines a duplex LC pair within a shared boot construction; the actual boot dimensions and cable construction must be checked against the panel drawing.
Use this configuration when all twelve paths are needed at six duplex positions. The cable does not convert an optical protocol or create six independent transceiver channels by itself. A cassette must have the correct mating interface and internal mapping; the word “cassette” alone does not establish compatibility.
For other fiber counts or branch types, start with the MPO breakout and harness selection page. For the broader assembly range, visit MPO cabling.
Key Features
- One MPO-12/PC female connector and six LC/UPC uniboot duplex ends in the supplied design.
- Twelve OM3 multimode fibers, allocated as six duplex pairs.
- Aqua jacket for identification; color alone does not verify fiber performance.
- Source-listed lengths from 1 to 50 m, with branch-length requests recorded separately.
- Factory-selected fiber mapping; no field polarity change is offered by the supplied product description.
- A configuration record links the connector arrangement, branch labels, routing dimensions and acceptance requirements.
Technical Specifications
Specification status: Product identity is taken from the supplied file. Availability, limits and build details require the approved BWNFiber specification. Items marked confirmation with BWNFiber remain open before order release.
| Parameter | Supplied configuration / required confirmation |
|---|---|
| Document reference | 10; a document identifier, not a verified manufacturer part number |
| Product family | MPO breakout / harness cable |
| MPO end | MPO-12, PC, female / unpinned |
| LC ends | 6 × LC/UPC uniboot duplex |
| Fiber population | 12 fibers / 6 duplex pairs; exact position-to-pair mapping: confirmation with BWNFiber |
| Fiber type | OM3 multimode, 50/125 μm |
| Jacket color | Aqua |
| Source-listed overall lengths | 1 / 1.5 / 2 / 3 / 5 / 7 / 10 / 15 / 20 / 25 / 30 / 40 / 50 m |
| Overall-length datum | Connector reference planes, tolerance and equal/staggered branch measurement: confirmation with BWNFiber |
| Fanout lengths | 30 / 45 / 60 cm listed; default, tolerance and measurement points: confirmation with BWNFiber |
| Jacket requests | LSZH / OFNP / OFNR listed; exact cable construction, availability and documentation: confirmation with BWNFiber |
| Polarity requests | Type A / B / C listed; approve an end-view drawing and complete fiber map |
| Optical acceptance | Maximum insertion loss, minimum return loss, wavelength, reference method and measurement scope: confirmation with BWNFiber |
| Mechanical limits | Branch diameter, boot dimensions, bend radius, tensile limit and temperature limits: confirmation with BWNFiber |
| Standards / declarations | Applicable editions and exact product coverage, including source-listed IEC/TIA references and RoHS: confirmation with BWNFiber |
Selection Guidance
Check the six duplex landing positions
Record the panel or equipment model, LC adapter spacing, neighboring connector population and cable-management route. Uniboot describes the boot and cable arrangement; it does not establish a smaller LC mating pitch or guarantee more panel ports. Confirm latch access with adjacent ports occupied, then check the bend radius and service slack against the approved construction.
Separate fiber distribution from SR4 operation
A twelve-path harness feeding six duplex positions and an eight-active-fiber SR4 breakout perform different connection tasks. Do not substitute one on fiber count or connector appearance alone. Submit the module part numbers, host breakout setting and intended port assignments for engineering review.
Cisco’s QSFP module data sheet documents module-specific parallel interfaces and breakout use. It does not establish compatibility, speed or reach for this BWNFiber assembly.
Approve the map, not only the polarity letter
Request an MPO end view with viewing direction, key orientation and numbered positions. Map each position to the two LC sides of each labeled duplex branch. Check pinning and polish on the connector behind the mating adapter. A Type A/B/C label does not replace this map, and an uniboot housing does not imply field polarity switching.
Use the MPO channel polarity design guide for the full channel review. For a cassette connection, compare the cassette harness mapping guide.
Branch schedule for drawing approval
| Branch label | MPO positions | LC side A destination | LC side B destination | Route length |
|---|---|---|---|---|
| B1 | Assign on approved map | Enter port | Enter port | Enter requirement |
| B2 | Assign on approved map | Enter port | Enter port | Enter requirement |
| B3 | Assign on approved map | Enter port | Enter port | Enter requirement |
| B4 | Assign on approved map | Enter port | Enter port | Enter requirement |
| B5 | Assign on approved map | Enter port | Enter port | Enter requirement |
| B6 | Assign on approved map | Enter port | Enter port | Enter requirement |
This is a blank approval schedule, not a proposed pinout. All twelve optical positions must appear once in the approved map, with no omissions or unintended duplicates.
Set the acceptance requirements
Ask for fiber optic testing requirements to be written into the quotation: continuity, polarity, connector end-face inspection and agreed optical-loss measurements. Define the wavelength, reference method and whether a limit applies to one mated connector pair or the entire assembly. Testing scope, limits, reporting and traceability supplied by BWNFiber: confirmation with BWNFiber.
Applications
| Connection task | Why this configuration may fit | Check before approval |
|---|---|---|
| MPO panel to six duplex LC positions | Twelve paths are presented as six paired branches | Panel interfaces, pinning, polish and pair map |
| OM3 cassette distribution | A compatible MPO interface can route to the required LC pairs | Cassette internal wiring and occupied positions |
| Dense LC patching area | Shared-boot ends may simplify the local cable arrangement | Actual branch construction, access and bending space |
These are selection scenarios, not customer case studies. No speed, distance or equipment compatibility is promised from the cable name.
Order Guide
Keep the connector arrangement, OM3 fiber and six uniboot duplex ends fixed when requesting this item. Treat changes to LC construction or fiber grade as a separate configuration review.
| Order field | Information to send |
|---|---|
| Reference | Document 10 and approved drawing revision |
| Endpoint interfaces | MPO mating connector and six LC destination models |
| Fiber map | Requested Type A / B / C plus the approved position-to-branch schedule |
| Overall length | Metric length and connector reference points |
| Branch geometry | Equal or staggered branches, fanout datum and required lengths |
| Jacket | Requested material/rating, installation environment and destination market |
| Acceptance | Agreed limits, methods and required records |
| Commercial details | Quantity by configuration, sample request, delivery destination and required date |
The source lists 117 request combinations: 13 overall lengths × 3 polarity labels × 3 jacket requests. They are retained in the separate order matrix for review, without repeating the complete product name in every row. This is not a stock or availability statement. Metric length controls: 1 m ≈ 3.28 ft, 1.5 m ≈ 4.92 ft and 2 m ≈ 6.56 ft.
Custom lengths, 0.9 mm legs, staggered branches, pulling eyes, labels, packaging, MOQ and lead time: confirmation with BWNFiber. Do not use a pulling eye unless it is included in the approved assembly drawing and installation instructions.
Why Source from BWNFiber?
Ask BWNFiber to quote the six-pair connection against one agreed drawing, branch schedule and acceptance record. This gives purchasing, installation and receiving teams a common configuration reference, including any exceptions to the request.
The supplied material mentions termination, inspection, OEM printing and optical records. The corresponding fiber optic manufacturing process, inspection coverage and documents for this exact item remain confirmation with BWNFiber. Request evidence tied to the selected build rather than relying on a generic capability statement.