MPO Breakout & Harness Cable

MPO 12 Fiber OM3 to LC Duplex Breakout Cable

This MPO 12 fiber OM3 to LC duplex breakout cable brings twelve fibers from one female MPO-12 interface to six LC/UPC duplex connections. It is intended for an OM3 distribution path that needs all six fiber pairs presented at LC ports. Confirm the mating connector and the complete fiber map before selecting the assembly for a cassette, adapter panel or equipment connection.

MPO Breakout & Harness Cable

Product Overview

This MPO 12 fiber OM3 to LC duplex breakout cable brings twelve fibers from one female MPO-12 interface to six LC/UPC duplex connections. It is intended for an OM3 distribution path that needs all six fiber pairs presented at LC ports. Confirm the mating connector and the complete fiber map before selecting the assembly for a cassette, adapter panel or equipment connection.

A twelve-position MPO interface does not establish the number of active channels or a transceiver breakout mode. This product is specified as twelve populated fibers. A four-channel SR4 connection uses a different lane assignment and must be checked against the equipment documentation; six LC duplex branches alone do not establish SR4 compatibility.

Key Features

  • One MPO-12/PC female connector and six LC/UPC duplex branch connections.
  • Twelve populated OM3 multimode fibers, specified as 50/125 μm in the supplied product record.
  • Aqua jacket identification for the specified assembly.
  • Six duplex branch positions for an approved panel or cassette port map.
  • Overall length, branch geometry, jacket and polarity selected against a project drawing.

Specification notice: The interface, fiber and color description comes from the supplied product record. Final construction and available options are subject to BWNFiber confirmation before ordering.

Technical Specifications

ItemSpecification or confirmation required
Product familyMPO Breakout & Harness Cable
MPO endMPO-12/PC, female (unpinned), as specified in the supplied record
LC end6 × LC/UPC duplex connections; 12 LC fiber terminations
Populated fiber count12
Fiber gradeOM3 multimode, 50/125 μm
Jacket colorAqua
Overall lengthSupplied range: 1–50 m; availability and measurement datum require BWNFiber confirmation
Trunk / branch diameterSupplied proposal: 3.0 mm trunk / 2.0 mm duplex legs; requires BWNFiber confirmation
Branch lengthSupplied proposals: 30, 45 or 60 cm; equal or staggered construction requires BWNFiber confirmation
PolarityType A, B or C listed in the source; approve an MPO-position-to-LC-port drawing for the actual assembly
Jacket optionsLSZH, OFNP and OFNR listed in the source; available construction and supporting documentation require BWNFiber confirmation
Insertion loss / return lossNo approved limits supplied; request the test specification, wavelength and reference method
Mechanical and environmental limitsBend radius, tensile limits, operating temperature and storage temperature require BWNFiber confirmation
ComplianceNo product-specific certification or declaration verified for this assembly

Selection Guidance

Match the six-pair termination

Required connectionSelection decision
Twelve populated fibers presented as six LC duplex pairsReview this configuration against the mating interface and port map
Eight active fibers presented as four duplex pairsSelect an eight-fiber assembly after checking equipment lane assignments
Twelve independent LC simplex endsRequest the simplex termination build; do not assume the duplex clips are removable
A pinned MPO connector is requiredRequest the male configuration; this record specifies female
A shared-jacket LC uniboot construction is requiredRequest the uniboot build; it is a separate construction requirement

Confirm the whole connection path

Female identifies the MPO connector’s unpinned state. Check the connector on the other side of the mating interface, its pin state and key orientation. An adapter housing does not by itself establish pin compatibility. Use a mating pair with compatible alignment pins and matching end-face geometry.

For a cassette installation, identify whether the assembly connects at the rear MPO port or forms an internal harness. Confirm space for the breakout transition, branch routing and LC orientation. The phrase “cassette harness” alone does not prove that a finished external cable will fit inside a cassette.

Approve a fiber map

Ask for a drawing that records each MPO position, the corresponding LC branch and the A/B side of each duplex pair. Include the viewing direction and key reference. A Type A/B/C label alone leaves room for different interpretations across the complete channel.

For background, consult the cassette harness port-mapping guide. The product drawing should carry the actual wiring used for this order.

Applications

  • Presenting six OM3 duplex pairs from a compatible populated MPO distribution connection to LC adapter ports.
  • Replacing an existing six-pair harness when connector type, pin state, fiber grade and wiring match the installed path.
  • Preparing a panel or cassette assembly where the approved drawing defines branch lengths and port labels.

Network speed and reach depend on the transceivers, channel length, connection count and optical loss budget. Do not assign a 40G, 100G or other data-rate guarantee from the cable name or jacket color.

Order Guide

Configure one assembly

RFQ fieldInformation to send
Fixed buildMPO-12/PC female → 6 × LC/UPC duplex; 12 fibers; OM3; aqua
Mating hardwareEquipment or cassette part number, connector pin state and interface drawing
Fiber mapMPO position → LC branch → duplex A/B; identify viewing direction
Overall lengthRequired length in meters and agreed measurement points
Branch layoutLength of each leg, equal/staggered layout, breakout position and routing limits
JacketRequired construction and destination-specific documentation
Optical acceptanceLoss limits, test wavelength, reference method and report format
Commercial detailsQuantity, destination, required delivery date, labeling and packaging needs

Length requests

The source lists the following nominal metric lengths. These are quotation candidates, not verified stock. Confirm the finished length tolerance and connector measurement points on the drawing.

Length (m)Approximate length (ft)
13.28
1.54.92
26.56
39.84
516.40
722.97
1032.81
1549.21
2065.62
2582.02
3098.43
40131.23
50164.04

Meters govern the request; feet are approximate conversions. Custom lengths, 0.9 mm branches, pulling eyes, staggered legs and private-label packaging require BWNFiber confirmation. MOQ, sample availability, price and lead time are quoted for the approved build and quantity.

Why Source from BWNFiber

Use this product record to define one consistent assembly for technical review and quotation. Send the same drawing revision, pin state, port map and acceptance requirements with every repeat order so that substitutions can be identified before approval.

Quality and acceptance documents

Request a drawing revision, material and connector identification, continuity and polarity record, and optical loss report linked to the supplied assembly or batch. Agree the test wavelengths, reference setup and pass limits before accepting results. No measured performance values or automatic inclusion of reports are claimed here; document availability requires BWNFiber confirmation.

Treat LSZH material requirements and OFNP/OFNR classifications as separate checks. Ask for the documentation applicable to the exact jacket construction and installation specification. Listing a standard number in a catalog is not proof of product certification.

See the MPO breakout and harness cable range to compare other fiber counts and branch formats.

For assemblies with different branch connectors, review the MPO/MTP breakout and fan-out product record. If the project needs a protected interface, use the IP-Series assembly record and confirm its environmental qualification separately.

Need a Configuration Review or Sample?

Send your six-pair port map, mating hardware part number, length, jacket requirement and quantity to BWNFiber. Ask for the confirmed build, applicable test documentation and quotation before approving an order.

Request a Configuration Review

FAQ

21. Intent Gap

Does six LC duplex mean six fibers?

No. Each duplex connection contains two fiber terminations. Six duplex connections account for twelve fibers. Confirm both LC positions in every pair on the drawing.

Can I use this as a four-channel SR4 breakout?

Do not select it on connector fit alone. This record describes twelve populated fibers and six duplex pairs. Check the transceiver model, supported breakout mode and lane map before selecting a dedicated four-pair connection.

What does female MPO mean on this product?

Female means the MPO connector is unpinned. Verify the mating connector’s alignment pins, key orientation and polish; the adapter body alone does not establish compatibility.

Is the LC end uniboot?

The supplied record calls for LC/UPC duplex ends. It does not establish a uniboot housing or shared-jacket construction. Specify uniboot separately if required.

Can the LC duplex ends be separated into simplex connectors?

Do not assume this. Confirm the connector housing and clip design, or request a purpose-built simplex assembly.

Which polarity should I order?

Use the complete channel drawing. Record MPO positions and LC branch A/B assignments, then have the requested polarity confirmed for the order. Type labels alone are insufficient for a mixed cassette-and-harness path.

Does a 30 cm branch come as standard?

The source proposes a 30 cm default and 45/60 cm alternatives, but none has been verified against an approved drawing. Specify the required branch length and tolerance in the RFQ.

Are all listed lengths available with every jacket?

The source lists combinations, but this is not evidence of stock or qualification for every combination. Confirm length, jacket construction, availability and quantity together.

What insertion loss and return loss are guaranteed?

No approved limits were supplied for this build. Request the optical test specification and a representative report. Do not transfer limits from a different cable family.

What should I send for a repeat order?

Provide the approved part number and drawing revision, fiber map, length, jacket, quantity, label text and acceptance criteria. Identify any requested substitution for review before approval.


| — | —: | —: | — |

| — | — | — |

22. Information Gain

An MPO-12 OM3 harness with six LC duplex connections carries twelve populated fibers to six fiber pairs. The connector interface alone does not establish transceiver compatibility. Confirm the mating connector, fiber map and branch dimensions against the equipment or panel drawing before selecting this distribution assembly.

For a six-pair OM3 distribution requirement, specify the female MPO-12 end, six LC/UPC duplex connections and all twelve populated fibers. Record the mating hardware, key orientation, branch labels and MPO-position-to-LC-pair map. Include overall length, measurement points, branch geometry, jacket requirements and quantity in the quotation request. Ask for the approved drawing revision and the optical acceptance method, wavelengths and pass limits. The supplied product record does not verify every option or certify performance. BWNFiber must confirm the final construction, documentation, sample availability and commercial terms before an order is approved.

| — | — | — | — |

| — | —: | —: | — |

| — | — | — |

  • product: deterministic grader REVISE / 74.3;compliance exit 0。
  • category: deterministic grader REVISE / 70.0;compliance exit 0。

32. Website Content Uniqueness Certification

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.