MPO Breakout & Harness Cable

MPO-12 OM3 Male to LC Duplex Type B Breakout Cable

Review the MPO-12 OM3 male to LC Type B harness with six duplex pairs. Confirm pinning, fiber mapping and dimensions before requesting a quote.

MPO Breakout & Harness Cable

The MPO-12 OM3 male to LC duplex Type B breakout cable is specified with one pinned MPO-12/PC connector and six LC/UPC duplex pairs. Its twelve fibers provide six separate duplex paths for a matching OM3 distribution link. Confirm the mating connector and the complete fiber map before selecting this configuration.

Product Overview

Use this configuration when a twelve-fiber distribution connection requires a male MPO end and six labeled LC duplex destinations. The supplied product specification identifies OM3 50/125 μm fiber, an aqua jacket and factory-fixed Type B wiring. It does not establish a universal switch or transceiver compatibility list.

Disclaimer — configuration status: This product description follows the supplied specification. The released BOM, MPO-to-LC wiring drawing and orderable part number are confirmation with BWNFiber. Request those documents before approving a production order.

Key Features

  • One MPO-12/PC male connector, with guide pins, at the multi-fiber end.
  • Six LC/UPC duplex pairs using twelve fibers; pair labels must follow the approved drawing.
  • OM3 multimode fiber, 50/125 μm, with aqua jacket specified in the source.
  • Fixed Type B configuration; no field polarity-change feature is claimed.
  • Length and jacket requirements can be submitted for quotation after interface and mapping review.

Technical Specifications

ItemSupplied configurationConfirmation required
Multi-fiber connectorMPO-12/PC male, pinnedConnector BOM, key orientation and mating-face reference
Branch connectors6 × LC/UPC duplexPair numbering and LC A/B orientation
Fiber count12 fibersPosition-to-leg continuity drawing
Fiber gradeOM3, 50/125 μmApproved cable specification
Jacket colorAquaProduction color and identification
PolarityType B, factory-fixedComplete MPO-position-to-LC-end map
Overall lengthSource lists 1–50 mLength datum, tolerance and orderable values
Fanout lengthSource lists 30 / 45 / 60 cmAvailable constructions and measurement datum
Jacket optionsSource lists LSZH, OFNP and OFNRExact cable construction and supporting rating documents
Insertion loss / return lossNo verified limits suppliedLimits, wavelength, reference method and measurement scope
Operating conditionsNot established in the sourceTemperature, bend radius and installation constraints

All availability, test-limit and compliance fields above are confirmation with BWNFiber. Neither a jacket description nor a standards reference establishes certification for the finished assembly.

Selection Guidance

Check the mating connector behind the adapter

Male and female identify MPO connector pinning. This male end needs an appropriate unpinned mating connector, with compatible polish and keying. An adapter aligns the connection; its housing alone does not establish the pin state of the connector behind it. Do not force two pinned connectors together.

The connector distinction is described by Fluke Networks’ MPO interface reference. It explains the interface principle; it does not certify this BWNFiber configuration.

Approve all twelve paths, not just the Type B label

A Type B label is not a substitute for the harness drawing. Record the viewing direction at the MPO face, the key orientation, each occupied position, the LC pair number and the A/B end of each pair. Then check that the complete installed channel connects transmit to receive.

Drawing acceptance checklist

  1. Identify the exact mating connector and its pin state.
  2. State the MPO mating-face view and mark position 1.
  3. Map all twelve MPO positions to individual LC ends.
  4. Label six duplex pairs and their destination ports.
  5. Approve the drawing revision against the complete channel plan.

No numerical pin map is supplied here because the approved wiring drawing is confirmation with BWNFiber. For the wider channel design, consult the MPO polarity channel planning guide.

Separate distribution from equipment breakout

RequirementMatch to this configurationRequired action
OM3 distribution to six duplex destinationsCandidate when the far end is unpinned and the approved map matchesConfirm the full channel drawing
A pinned mating interfacePin arrangement does not match this male endSelect a separately qualified female-end configuration
Four-duplex SR4 breakoutDifferent active-path and branch requirementReview an equipment-specific assembly and switch mode
Single-mode optical linkDifferent fiber requirementReview the corresponding single-mode product
A Type A or Type C order specificationDifferent fixed wiring requirementRequest the correct SKU; do not substitute this Type B item

A passive harness does not create a switch breakout mode. An MPO-12 shell can also be used in an eight-active-fiber application, so connector format alone does not prove a twelve-path or SR4 mapping. Confirm exact equipment models and optical interfaces whenever equipment breakout is involved.

Applications

  • Trunk-to-duplex distribution in an OM3 rack or patching area, where the mating connector is unpinned and the channel drawing matches.
  • Panel integration requiring six identified duplex destinations and a controlled MPO-to-LC map.
  • Replacement of an existing harness with the same verified pinning, fiber grade, wiring revision and dimensions.

For an internal cassette installation, check branch protection, enclosure space and bend requirements separately. Review the breakout-versus-cassette architecture comparison before choosing an exposed harness or enclosed transition. These examples describe selection conditions, not tested customer installations or guaranteed equipment compatibility.

Order Guide

Keep the optical identity fixed: MPO-12/PC male, six LC/UPC duplex pairs, twelve OM3 fibers and Type B wiring. Submit length and jacket requirements against this identity. A change to gender, fiber type, branch count or polarity requires a separately reviewed configuration.

Requested length, mApproximate feet
13.28
1.54.92
26.56
39.84
516.40
722.97
1032.81
1549.21
2065.62
2582.02
3098.43
40131.23
50164.04

These are the source-listed metric lengths with rounded unit conversions, not stock confirmations. Metric dimensions control unless the approved drawing states otherwise. Specify whether the overall length includes the fanout and identify the measurement points.

For LSZH, OFNP or OFNR requests, state the installation requirement and ask for documentation covering the offered construction. Do not treat those descriptions as interchangeable. Branch lengths, 0.9 mm legs, staggered fanout, pulling eyes, custom overall lengths, OEM labels and packaging remain confirmation with BWNFiber; none is an approved option solely because it appears in the supplied draft.

Quality and Acceptance Documents

Before ordering, ask BWNFiber to confirm the fiber optic testing scope for this assembly. Request a report format that identifies the assembly or batch, drawing revision, tested path, wavelength, reference method, acceptance limit and measured result. Agree whether return-loss measurements and end-face inspection are included.

Separate a connector specification from an assembly result and from the total installed-channel budget. Do not copy loss limits from the general family page onto this SKU without a matching approved test specification. Request a pilot sample where the installation requires qualification; availability and terms are confirmation with BWNFiber.

The supplied list of TIA, IEC and RoHS references has not been accepted as a declaration of conformity. Applicable editions, certificates, declarations and product-specific reports must be reviewed before any compliance claim is published.

Why Source from BWNFiber

Use the configuration review to establish one agreed specification for quotation, sample evaluation and repeat purchasing. Ask BWNFiber to confirm its fiber optic manufacturing scope for the proposed BOM, including connector sourcing, assembly identity, inspection records and any outsourced operations. This draft makes no claim about factory ownership, production capacity, certification, MOQ or delivery time.

Browse the MPO breakout and harness range for other connection tasks. The broader fanout assembly family lists additional configurations; each requires its own approved specification.

FAQ

Need a Configuration Review or Sample?

Why choose the male MPO version?

Choose it only when the actual mating connector is unpinned and the remaining interface details match. The adapter housing alone does not answer that question.

Are there six or twelve LC connections?

The source specifies six duplex pairs, comprising twelve individual LC fiber ends. Pair labels and destination ports must be shown on the approved drawing.

Does Type B identify each LC pair automatically?

No. Request the mating-face view and the complete position-to-leg drawing, including pair numbering and LC A/B orientation.

Can this replace a female OM3 harness?

Only after a new interface review. Changing pinning changes the mating requirement; two visually similar harnesses may not be interchangeable.

Is this a standard four-channel SR4 breakout cable?

It is described as a twelve-fiber, six-duplex distribution harness. Do not order it as a four-duplex equipment breakout without a separately verified equipment and lane-map specification.

Does the aqua jacket prove OM3?

Use the cable specification and product identification to establish fiber grade. Color supports identification but does not replace documentary verification.

Can the polarity be changed in the field?

No field-change feature is established for this configuration. Specify the required wiring before ordering and control later changes through a revised drawing.

Which length measurement should appear on the order?

State the approved endpoints for overall length and branch reach, plus tolerances. Confirm whether fanout length is included in the overall dimension.

Which loss limits should I use for acceptance?

Use the agreed limits for the defined measurement scope and wavelength. No product-specific guaranteed IL or RL value has been verified for this draft.

What should I include in a repeat order?

Use the approved part number, drawing revision, length, jacket construction, labels and test requirements. Identify any change so that an earlier sample approval is not applied to a different build.

Send the mating connector or equipment model, six destination port labels, complete channel map, overall length, branch reach, jacket requirement and quantity. Include the destination market and required project date. Ask BWNFiber to confirm feasibility, sample terms, test documentation, MOQ and lead time for the exact configuration.

RFQ text: “Please review an MPO-12/PC male to six LC/UPC duplex OM3 Type B harness. Mating connector: ; drawing revision: ; LC pair destinations: ; length datum and overall length: ; branch reach: ; jacket requirement: ; quantity: __. Please confirm the BOM, acceptance limits, documentation and quotation terms.”


Upload Notes — Not Page Body

Photo file suggested in source: mpo-12f-om3-male-to-lc-duplex-type-b-breakout-cable.jpg. Use the actual prepared image filename; no photo was generated or renamed. Proposed alt: “Aqua OM3 harness with one pinned MPO-12 connector and six LC duplex pairs.” Verify against the photograph; polarity cannot be proved by appearance.

Breadcrumb: Home → Products → Data Center Solutions → MPO Cabling → MPO Breakout & Harness Cable → product name. Use the approved URL only; the nested path remains a proposal.

Use Product and BreadcrumbList only after approved identity, actual image URL and canonical are available. Do not invent offers, prices, availability, reviews, ratings, SKU or certifications. No claim of Product rich-result eligibility is made. No Article or HowTo schema is proposed for this SKU. FAQ remains visible content; do not promise FAQ rich results. Schema guidance: https://developers.google.com/search/docs/appearance/structured-data/product-snippet

Engineering reviewer, role, approval date and evidence references: confirmation with BWNFiber. A named reviewer must not be fabricated to satisfy a grader. Keep this draft offline until those gates close.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.