The MPO-12 OM3 male to LC duplex Type B breakout cable is specified with one pinned MPO-12/PC connector and six LC/UPC duplex pairs. Its twelve fibers provide six separate duplex paths for a matching OM3 distribution link. Confirm the mating connector and the complete fiber map before selecting this configuration.
Product Overview
Use this configuration when a twelve-fiber distribution connection requires a male MPO end and six labeled LC duplex destinations. The supplied product specification identifies OM3 50/125 μm fiber, an aqua jacket and factory-fixed Type B wiring. It does not establish a universal switch or transceiver compatibility list.
Disclaimer — configuration status: This product description follows the supplied specification. The released BOM, MPO-to-LC wiring drawing and orderable part number are confirmation with BWNFiber. Request those documents before approving a production order.
Key Features
- One MPO-12/PC male connector, with guide pins, at the multi-fiber end.
- Six LC/UPC duplex pairs using twelve fibers; pair labels must follow the approved drawing.
- OM3 multimode fiber, 50/125 μm, with aqua jacket specified in the source.
- Fixed Type B configuration; no field polarity-change feature is claimed.
- Length and jacket requirements can be submitted for quotation after interface and mapping review.
Technical Specifications
| Item | Supplied configuration | Confirmation required |
|---|---|---|
| Multi-fiber connector | MPO-12/PC male, pinned | Connector BOM, key orientation and mating-face reference |
| Branch connectors | 6 × LC/UPC duplex | Pair numbering and LC A/B orientation |
| Fiber count | 12 fibers | Position-to-leg continuity drawing |
| Fiber grade | OM3, 50/125 μm | Approved cable specification |
| Jacket color | Aqua | Production color and identification |
| Polarity | Type B, factory-fixed | Complete MPO-position-to-LC-end map |
| Overall length | Source lists 1–50 m | Length datum, tolerance and orderable values |
| Fanout length | Source lists 30 / 45 / 60 cm | Available constructions and measurement datum |
| Jacket options | Source lists LSZH, OFNP and OFNR | Exact cable construction and supporting rating documents |
| Insertion loss / return loss | No verified limits supplied | Limits, wavelength, reference method and measurement scope |
| Operating conditions | Not established in the source | Temperature, bend radius and installation constraints |
All availability, test-limit and compliance fields above are confirmation with BWNFiber. Neither a jacket description nor a standards reference establishes certification for the finished assembly.
Selection Guidance
Check the mating connector behind the adapter
Male and female identify MPO connector pinning. This male end needs an appropriate unpinned mating connector, with compatible polish and keying. An adapter aligns the connection; its housing alone does not establish the pin state of the connector behind it. Do not force two pinned connectors together.
The connector distinction is described by Fluke Networks’ MPO interface reference. It explains the interface principle; it does not certify this BWNFiber configuration.
Approve all twelve paths, not just the Type B label
A Type B label is not a substitute for the harness drawing. Record the viewing direction at the MPO face, the key orientation, each occupied position, the LC pair number and the A/B end of each pair. Then check that the complete installed channel connects transmit to receive.
Drawing acceptance checklist
- Identify the exact mating connector and its pin state.
- State the MPO mating-face view and mark position 1.
- Map all twelve MPO positions to individual LC ends.
- Label six duplex pairs and their destination ports.
- Approve the drawing revision against the complete channel plan.
No numerical pin map is supplied here because the approved wiring drawing is confirmation with BWNFiber. For the wider channel design, consult the MPO polarity channel planning guide.
Separate distribution from equipment breakout
| Requirement | Match to this configuration | Required action |
|---|---|---|
| OM3 distribution to six duplex destinations | Candidate when the far end is unpinned and the approved map matches | Confirm the full channel drawing |
| A pinned mating interface | Pin arrangement does not match this male end | Select a separately qualified female-end configuration |
| Four-duplex SR4 breakout | Different active-path and branch requirement | Review an equipment-specific assembly and switch mode |
| Single-mode optical link | Different fiber requirement | Review the corresponding single-mode product |
| A Type A or Type C order specification | Different fixed wiring requirement | Request the correct SKU; do not substitute this Type B item |
A passive harness does not create a switch breakout mode. An MPO-12 shell can also be used in an eight-active-fiber application, so connector format alone does not prove a twelve-path or SR4 mapping. Confirm exact equipment models and optical interfaces whenever equipment breakout is involved.
Applications
- Trunk-to-duplex distribution in an OM3 rack or patching area, where the mating connector is unpinned and the channel drawing matches.
- Panel integration requiring six identified duplex destinations and a controlled MPO-to-LC map.
- Replacement of an existing harness with the same verified pinning, fiber grade, wiring revision and dimensions.
For an internal cassette installation, check branch protection, enclosure space and bend requirements separately. Review the breakout-versus-cassette architecture comparison before choosing an exposed harness or enclosed transition. These examples describe selection conditions, not tested customer installations or guaranteed equipment compatibility.
Order Guide
Keep the optical identity fixed: MPO-12/PC male, six LC/UPC duplex pairs, twelve OM3 fibers and Type B wiring. Submit length and jacket requirements against this identity. A change to gender, fiber type, branch count or polarity requires a separately reviewed configuration.
| Requested length, m | Approximate feet |
|---|---|
| 1 | 3.28 |
| 1.5 | 4.92 |
| 2 | 6.56 |
| 3 | 9.84 |
| 5 | 16.40 |
| 7 | 22.97 |
| 10 | 32.81 |
| 15 | 49.21 |
| 20 | 65.62 |
| 25 | 82.02 |
| 30 | 98.43 |
| 40 | 131.23 |
| 50 | 164.04 |
These are the source-listed metric lengths with rounded unit conversions, not stock confirmations. Metric dimensions control unless the approved drawing states otherwise. Specify whether the overall length includes the fanout and identify the measurement points.
For LSZH, OFNP or OFNR requests, state the installation requirement and ask for documentation covering the offered construction. Do not treat those descriptions as interchangeable. Branch lengths, 0.9 mm legs, staggered fanout, pulling eyes, custom overall lengths, OEM labels and packaging remain confirmation with BWNFiber; none is an approved option solely because it appears in the supplied draft.
Quality and Acceptance Documents
Before ordering, ask BWNFiber to confirm the fiber optic testing scope for this assembly. Request a report format that identifies the assembly or batch, drawing revision, tested path, wavelength, reference method, acceptance limit and measured result. Agree whether return-loss measurements and end-face inspection are included.
Separate a connector specification from an assembly result and from the total installed-channel budget. Do not copy loss limits from the general family page onto this SKU without a matching approved test specification. Request a pilot sample where the installation requires qualification; availability and terms are confirmation with BWNFiber.
The supplied list of TIA, IEC and RoHS references has not been accepted as a declaration of conformity. Applicable editions, certificates, declarations and product-specific reports must be reviewed before any compliance claim is published.
Why Source from BWNFiber
Use the configuration review to establish one agreed specification for quotation, sample evaluation and repeat purchasing. Ask BWNFiber to confirm its fiber optic manufacturing scope for the proposed BOM, including connector sourcing, assembly identity, inspection records and any outsourced operations. This draft makes no claim about factory ownership, production capacity, certification, MOQ or delivery time.
Browse the MPO breakout and harness range for other connection tasks. The broader fanout assembly family lists additional configurations; each requires its own approved specification.