Product Introduction
This MPO 12 fiber OM2 to LC duplex breakout cable is specified for replacement work on an existing OM2 fiber plant. The supplied configuration has one pinned MPO-12/PC connector and six LC/UPC duplex terminations. It presents twelve individual fiber paths as six duplex pairs; the approved drawing must identify each path before ordering.
Specification disclaimer: The configuration below comes from supplied product material and is subject to an approved datasheet and drawing. Final BOM, dimensions, optical limits, jacket documentation, availability and commercial terms are confirmation with BWNFiber before order approval.
Use this model when the installed system calls for an OM2 harness with this endpoint arrangement. Orange jacket color can help identify the assembly but does not establish the fiber grade. Match the installed cable records and optical equipment documentation. A replacement harness does not upgrade the bandwidth of the existing plant.
Request an OM2 replacement review with the old part number, endpoint details and a marked-up routing drawing.
Key Features
- One MPO-12/PC male interface: the pinned connector requires a compatible unpinned mating connector.
- Six LC/UPC duplex terminations: identify both fibers within every duplex pair.
- OM2 multimode fiber with an orange jacket, as described in the supplied configuration.
- A full twelve-position distribution task, distinct from assuming that any twelve-position connector is a parallel-optics breakout.
- A replacement-focused approval process covering the old map, physical fit and optical acceptance evidence.
Specifications
| Parameter | Supplied configuration or approval requirement |
|---|---|
| Assembly role | MPO breakout / harness for an existing OM2 requirement |
| MPO endpoint | MPO-12/PC, male / pinned |
| Branch endpoints | 6 × LC/UPC duplex |
| Fiber paths | 12; position-to-position map requires approval |
| Fiber grade | OM2 multimode; confirm against BOM and installed cable record |
| Jacket color | Orange; color alone is not fiber-grade evidence |
| Overall length | Source lists 1–50 m; released lengths and measurement datums are confirmation with BWNFiber |
| Branch length | Source lists 30 / 45 / 60 cm; selected geometry and default are confirmation with BWNFiber |
| Polarity | Source lists A / B / C; exact MPO-position-to-LC map is confirmation with BWNFiber |
| Jacket specification | LSZH / OFNP / OFNR appear in source; construction and supporting classification records are confirmation with BWNFiber |
| Optical acceptance | IL / RL limits, wavelength, method, reference conditions and report scope are confirmation with BWNFiber |
| Mechanical limits | Cable diameter, branch diameter, bend radius and pulling limits are confirmation with BWNFiber |
| Compliance | Applicable standards, editions and product evidence are confirmation with BWNFiber; no certification claim is made here |
Confirm the mating connector
The male designation refers to pins in the MPO ferrule. Check the connector on the other side of the connection, including inside a cassette or behind an adapter. An adapter’s key orientation and the mating connector’s pin state are separate checks. Do not mate this pinned connector to another pinned connector. SENKO’s MPO polarity explanation distinguishes connector gender from adapter orientation.
Confirm all six duplex pairs
Ask for a drawing that lists MPO positions 1–12, the corresponding LC endpoint IDs, duplex pair IDs and label text. Record the viewing direction and key orientation on that drawing. A polarity letter alone does not show which installed LC port should receive each branch. Do not infer a completed pin map from the product name.
Applications
| Replacement situation | Candidate fit | Evidence needed before approval |
|---|---|---|
| Existing OM2 frame with six duplex endpoints | Candidate when the same twelve paths are required | Old part number, installed fiber record and endpoint map |
| Rack rearrangement retaining the optical system | Candidate if revised branches reach the correct ports | Port-row sketch, transition location and service-loop dimensions |
| Distributor repeat order | Candidate only against an accepted configuration | Prior drawing revision, labels and acceptance records |
| New optical system or changed transmission rate | Engineering selection required | Exact optics, host mode, medium specification and complete channel budget |
Do not select this model solely because a module has an MPO-shaped port. A 40G/100G SR4 application requires its own supported medium, populated-position map and host configuration. This page makes no SR4 compatibility claim and does not position OM2 as an OM4 or OM5 upgrade.
Compare Replacement Decisions
| What you know | What it does not prove | Next check |
|---|---|---|
| The old jacket is orange | Whether the installed fiber is OM1 or OM2 | Read the cable marking, BOM or accepted test documentation |
| The housing has twelve positions | That all positions or six duplex pairs are used in the same way | Compare the complete endpoint map |
| The old cable fits the adapter | Correct pin pairing and key orientation | Inspect the actual mating connectors and interface drawing |
| The replacement is the same overall length | Branches will reach the same port rows | Compare the breakout location and each branch dimension |
| A supplier lists the same jacket abbreviation | Equivalent installation classification | Request the exact cable construction and applicable evidence |
| The assembly passes continuity | The installed optical channel meets its application budget | Review agreed optical measurements and channel conditions |
For other configurations, use the MPO breakout and harness selection page. Keep a different fiber grade or endpoint arrangement on its own approved specification.
Order Guide
Build the replacement record
- Identify the existing assembly and installed fiber grade. Include the manufacturer part number, cable marking and any accepted drawing revision.
- Record both endpoint interfaces. Include pin state, finish, orientation and the equipment or cassette part number.
- Identify all twelve fiber paths and six duplex pair labels. Have the drawing reviewed against the installed port schedule.
- Specify the overall route, breakout transition point and each branch length. State dimensions in metres or millimetres and agree on measurement datums.
- Provide the installation location, jacket documentation requirement, quantity, destination and required date.
- Agree on sample acceptance, optical evidence and change control before approving a repeat or bulk order.
Length references for the inquiry
The source lists the following candidate lengths. Feet are approximate conversions, not additional stock-keeping units. Availability is confirmation with BWNFiber.
| Metres | Approximate feet | Metres | Approximate feet |
|---|---|---|---|
| 1 | 3.28 | 1.5 | 4.92 |
| 2 | 6.56 | 3 | 9.84 |
| 5 | 16.40 | 7 | 22.97 |
| 10 | 32.81 | 15 | 49.21 |
| 20 | 65.62 | 25 | 82.02 |
| 30 | 98.43 | 40 | 131.23 |
| 50 | 164.04 | Custom | Confirm feasibility |
Choose polarity and jacket only after the optical map and installation requirements are established. The source’s three polarity labels, three jacket labels and thirteen lengths produce 117 listed combinations; that multiplication does not demonstrate 117 released or stocked products. Request the approved order code rather than building a purchase order from an illustrative naming pattern.
Customization and Quality Review
Requests requiring a drawing review
Submit proposed changes to length, branch staggering, labels and packaging. A female connector, a different fiber grade, pulling accessories or a different branch construction changes the specified build. These requests require separate feasibility and quotation confirmation; they are not approved options of this male OM2 model merely because a similar product offers them. MOQ, delivery, samples and custom manufacturing capability are confirmation with BWNFiber.
Acceptance evidence
For fiber optic testing, agree on continuity, the full fiber map, connector end-face condition and optical measurements appropriate to the assembly. Specify the measurement wavelength, reference procedure, acceptance limits and report identification. Ask how the records will trace to the delivered assembly and drawing revision. A short harness test and an installed-channel acceptance test serve different purposes.
For fiber optic manufacturing review, request the BOM and a controlled drawing identifying the two connector systems, fiber grade, branch layout and jacket construction. Do not accept a general company certificate as proof that this configuration meets a particular product requirement. Any standard or regulatory statement must match the product evidence and its applicable edition.
Resolve a mismatch before repeating the order
If the sample has correct continuity but wrong port labels, correct the drawing and labeling before a bulk order. If it fits mechanically but lacks an agreed optical report, close the acceptance record before approval. If the supplied connector, jacket or branch geometry differs from the accepted drawing, obtain engineering disposition rather than treating the change as equivalent by appearance.