Pre-Terminated Fiber Cable

IP-Series ODVA MPO/APC Male to 8 LC/UPC Outdoor Patch Cord, 8F G.657.A2

IP-Series ODVA MPO/APC male to eight LC/UPC simplex legs on an 8-fiber G.657.A2 assembly with a 6.2 mm black LSZH main cable. Specify the mating interface, fiber map, fan-out and length before production.

8-Fiber IP-Series MPO-to-LC Configuration

This configuration has a protected IP-Series ODVA MPO/APC male connector at End A and eight LC/UPC simplex legs at End B. The supplied drawing reference is IP MPO APC(M)-LC UPC-6.2mm-SM-8F-xxxM. Match the End-A mating port and approve the complete fiber assignment before ordering.

Configuration and Technical Details

ParameterSupplied configuration
End AIP-Series ODVA MPO/APC male (pinned), with protective dust cap
End B8 × LC/UPC simplex connector legs
Active fibers8 live fibers in an MPO-12 ferrule
FiberG.657.A2, 9/125 µm single-mode
Main cable6.2 mm black LSZH in the supplied configuration
Fan-out2.0 mm LC legs; 400 ± 50 mm fan-out stated in the supplied drawing
Overall length1–150 m or a project-specific length, subject to the approved drawing
Optical and environmental acceptanceAgree on test limits, test records and the exact mated-interface condition for the project.

Eight-Leg Fiber Assignment

The supplied drawing lists active MPO positions 1–4 and 9–12; positions 5–8 are unpopulated. Orientation and end-to-end mapping must be checked against the actual equipment port.

MPO positionFiber colorLC leg
1Blue1
2Orange2
3Green3
4Brown4
9Yellow5
10Violet6
11Rose7
12Aqua8

Where the 8F Assembly Fits

Use this configuration for a defined FTTA, outdoor-cabinet or industrial link that requires a matching protected MPO-side connection and eight individually terminated LC/UPC legs. A standard indoor MPO port is not automatically compatible with the IP-Series housing. The jacket and mated interface must be approved for the actual installation environment.

Specify Both Connector Ends Separately

The supplied MPO end is APC male; the eight LC legs are UPC. The term “UPC” in a shortened product name describes the LC end, not the MPO end. Check the mating series, pinning, key orientation and LC-leg labels against the equipment drawing.

Information to Include in an RFQ

  • Equipment-port and mating-connector details for the protected MPO end
  • Eight-LC leg numbering, fiber map and required polarity
  • G.657.A2 fiber and approved main-cable/jacket construction
  • Measured route, overall length, service loop and fan-out length
  • Pulling path, protective head, installation environment and quantity
  • Required optical acceptance limits and document format

BWNFiber can review the specified build and prepare a configuration drawing before production. For broader assembly selection, see Pre-Terminated Fiber Cable and the IP-Series MPO/MTP family.

FAQ

8F IP MPO-to-LC Patch Cord FAQ

Is this the same as the 12F IP MPO-to-LC cord?

No. This page describes eight live fibers in an MPO-12 ferrule and eight LC/UPC legs. A 12F build needs its own approved 12-position map.

Does LC/UPC in the name make the MPO end UPC?

No. The supplied End-A drawing specifies an MPO/APC male connector; UPC applies to the LC legs at End B.

Can I plug the protected MPO end into an indoor cassette?

Only when the cassette or adapter provides the exact matching IP-Series mating interface. Standard indoor MPO mating cannot be assumed.

What should I send for a quote?

Send the mating-port details, MPO orientation and pinning, eight-leg map, length, fan-out, jacket/environment, test requirements and quantity.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.