Outdoor Fiber Cable

GYXTC8Y 12F / 24F G.652.D Figure-8 PE Fiber Optic Cable

GYXTC8Y 12F / 24F G.652.D Figure-8 PE Fiber Optic Cable for outdoor plant use at 12F / 24F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Figure-8 Self-Supporting Fiber Optic Cable

GYXTC8Y

Product value summary

This page is intended to identify one GYXTC8Y configuration for buyers evaluating a 12-fiber or 24-fiber G.652.D cable with a PE sheath and integrated steel-wire messenger. The current internal record lists a 3.6(±0.2) × 5.8(±0.3) mm cable profile, a 1.6 mm messenger, E-glass yarn around the loose-tube unit, and a nominal cable weight of 55 kg/km.

Before quotation or production approval: request the controlled datasheet and drawing. BWNFiber must confirm that the stated profile and mechanical limits apply to the selected fiber count and must confirm the route, span, environmental load and hardware interface separately.

Short answer for buyers

GYXTC8Y identifies a Figure-8 cable family, not one universal construction. For this proposed 12F/24F G.652.D PE configuration, select one fiber count and confirm the complete row: fiber grade, tube, messenger type and diameter, strength yarn, finished dimensions, weight, tensile/crush conditions, bend limits and temperature ranges. Do not approve an aerial route from the model name, fiber count or messenger diameter alone.

Key features — pending source-document confirmation

  • Fiber count: 12F or 24F
  • Fiber grade: G.652.D
  • Cable construction: central PBT loose tube with jelly filling and E-glass yarn
  • Sheath: black PE
  • Integrated messenger: steel wire, stated diameter 1.6 mm
  • Stated cable profile: 3.6(±0.2) × 5.8(±0.3) mm
  • Stated nominal weight: 55 kg/km
  • Intended route: self-supporting aerial access link, subject to route and hardware approval

These are transcribed internal-record values, not a substitute for the controlled product datasheet or project drawing.

Technical specifications

Construction

Parameter12F24FEvidence status
Fiber gradeG.652.DG.652.DInternal draft; source file required
Loose-tube materialPBTPBTInternal draft; source file required
Loose-tube diameter2.8 ± 0.1 mm2.8 ± 0.1 mmTBC: confirm both counts
Tube fillingJellyJellyInternal draft; source file required
Loose-tube colorNaturalNaturalInternal draft; source file required
Strength member/yarnE-glass yarnE-glass yarnTBC: verify construction drawing
MessengerSteel wireSteel wireTBC: confirm solid/stranded description
Messenger diameter1.6 mm1.6 mmTBC: confirm both counts
Outer sheathBlack PEBlack PEInternal draft; source file required
Finished cable profile3.6(±0.2) × 5.8(±0.3) mm3.6(±0.2) × 5.8(±0.3) mmTBC: high-priority row check
Nominal cable weight55 kg/km55 kg/kmTBC: confirm per count
Armor layerTBC — source requiredTBC — source requiredRequired for differentiation

Optical characteristics

ParameterStated valueEvidence status
Attenuation at 1310 nm≤0.36 dB/kmInternal draft; confirm source and test condition
Attenuation at 1550 nm≤0.25 dB/kmInternal draft; confirm source and test condition
Cable cutoff wavelength≤1260 nmInternal draft; confirm notation/source
Mode field diameter at 1310 nm9.2 ± 0.4 µmInternal draft; confirm source
Mode field diameter at 1550 nm10.4 ± 0.5 µmInternal draft; confirm source
Zero-dispersion wavelength1312 ± 10 nmInternal draft; confirm source
Zero-dispersion slope≤0.090 ps/(nm²·km)Unit normalized editorially; source confirmation required
PMDTBC — source and unit requiredExcluded from this draft

The attenuation values above describe the stated cabled-fiber limits. They are not a complete end-to-end loss budget; connectors, splices, splitters, engineering margin and wavelength-specific equipment limits must be calculated separately.

Mechanical and environmental limits

ParameterStated valueRelease note
Bend radius under load20DTBC: confirm whether this is dynamic/installation and add static limit
Tensile load1000 NTBC: identify short-term/long-term/test condition
Crush resistance1000 N/10 cmTBC: identify test condition and method
Operating temperature−20°C to +70°CInternal draft; source confirmation required
Installation temperature−10°C to +60°CInternal draft; source confirmation required
Storage/transport temperatureTBC — source requiredDo not infer from operating range
Approved span, sag and tensionProject-specific; TBCRequires route engineering and hardware review

D means the finished cable diameter used by the controlled datasheet. Because this profile is Figure-8 shaped, BWNFiber must state which dimension governs each bend calculation before the value is used in an installation instruction.

Interfaces and connector options

This record describes bulk cable and does not identify factory-installed connectors or termination hardware. Connector type, termination method, closure entry, gland, clamp and pole-line hardware are TBC — source/project required. Do not present LC, SC, OptiTap or any other interface as included with P019 unless it appears on the approved BOM.

Fiber type and configuration options

Select either 12F or 24F. Do not combine the two counts in one order line. G.652.D is the only fiber grade shown in the current P019 record; any G.657 or multimode alternative requires a different approved configuration and source document.

Compatibility and application conditions

The stated use is an outdoor self-supporting aerial access link. This does not approve a particular span or installation. Before selection, provide:

  1. longest and ruling spans;
  2. pole/attachment geometry and clearances;
  3. wind, ice and temperature load case;
  4. sag/tension and safety-factor requirements;
  5. clamp, dead-end and suspension hardware interface;
  6. closure or terminal entry dimensions;
  7. required fiber reserve and splice plan;
  8. local code, route-owner and utility requirements.

If these inputs are unavailable, keep the application status as route review required.

How to select the correct configuration

  1. Choose 12F or 24F from the approved network capacity plan.
  2. Confirm the fiber grade and the exact count-specific construction row.
  3. Match the finished cable dimensions to the clamp, entry port, closure and routing space.
  4. Confirm messenger construction, mechanical limits and project load conditions.
  5. Check installation, operation, storage and transport temperature definitions separately.
  6. Approve the controlled datasheet, drawing, marking, packing and test-document requirements before the purchase order.

Difference from related BWNFiber products

Product/pageStated constructionBuyer-use boundaryStatus
P019 candidate12F/24F, G.652.D, PE, 1.6 mm steel wire, E-glass yarn, 3.6 × 5.8 mmExact configuration only, if source confirms itRevise
Live Aerial Figure 8 Unitube Armored Cable12F/24F rows, steel armor, 7 × 1.0 mm steel messenger, larger count-specific dimensionsArmored Figure-8 optionLive; do not copy values into P019
8 Type Aerial Self-supporting Drop CableDrop-cable page with different low-count/tight-buffer claims and LSZH recordFTTH drop-cable selectionDifferent product role
ADSS cable categoryAll-dielectric self-supporting route designRoutes requiring a non-metallic self-supporting cableDifferent family and engineering model

P019 should not become a separate page merely because its wording is different. It needs a confirmed structural and procurement distinction.

Use cases

  • Candidate for an outdoor aerial access route where this exact 12F or 24F construction, messenger and load case have been approved.
  • Candidate for distributor or project procurement requiring an exact GYXTC8Y configuration rather than a generic family label.

Do not claim duct, direct-burial, power-line, long-span, indoor, fire-rated, rodent-resistant or named-network compatibility without product and route evidence.

Testing and quality-control process

The current source package does not include an approved test plan. Before publishing a testing claim, BWNFiber QA must specify:

Control pointRequired evidenceStatus
Incoming fiber verificationFiber certificate or controlled supplier recordTBC
Construction/dimension checkDrawing, tolerance and inspection recordTBC
Attenuation checkWavelength, method, sample scope and acceptance limitTBC
Tensile/crush/bend testNamed method, condition, duration and acceptance criteriaTBC
Final length and markingReel/drum record and marking approvalTBC
Order release documentDatasheet/drawing revision accepted by buyerTBC

Do not promise a test report unless Sales/QA confirms which report is available for a sample, lot or finished order.

Packaging and procurement information

Packing type, standard length, length tolerance, reel/drum dimensions, net/gross weight, end protection, export treatment and labeling are TBC — source required. A buyer may request these fields in the RFQ; availability and final values must be returned in the quotation or approved packing specification.

Required information for an RFQ

Send the following as one configuration request:

  • product reference: GYXTC8Y P019 candidate;
  • fiber count: 12F or 24F;
  • fiber grade: G.652.D;
  • total quantity and total cable length;
  • required length per reel/drum and acceptable tolerance;
  • route type, longest/ruling span and environmental load case;
  • attachment/clamp/entry interface information;
  • cable marking text and language;
  • delivery destination and required trade documents;
  • required datasheet, drawing, inspection and test records;
  • sample or pre-production approval requirement.

Datasheet / drawing / test-report download area

  • Controlled product datasheet: TBC — source required
  • Dimensioned construction drawing: TBC — source required
  • Fiber specification/certificate: TBC — source required
  • Mechanical/environmental test method and report: TBC — source required
  • Packing specification: TBC — source required

Do not display inactive download buttons as if documents exist.

RFQ / CTA

Primary CTA: Request the controlled P019 configuration review

Send 12F or 24F, total length, reel/drum length, route/span data, environmental load case, hardware interface, marking and document requirements. BWNFiber should return either a count-specific datasheet/drawing for confirmation or a clarification list before quotation.

Secondary CTA: Compare this configuration with the armored Figure-8 option

Use this only after the P019 construction has been confirmed.

FAQ

Frequently asked questions

Does this page cover both 12F and 24F?

The current internal record lists 12F and 24F. BWNFiber must confirm the count-specific construction rows before publication, especially the finished dimensions and nominal weight.

Is this the same product as BWNFiber’s live Aerial Figure 8 Unitube Armored Cable?

That has not been established. The live page states steel armor, a 7 × 1.0 mm messenger and larger count-specific dimensions. P019 states a 1.6 mm steel wire, E-glass yarn and a 3.6 × 5.8 mm profile. The controlled drawing/BOM must decide whether P019 is a separate configuration or should be merged.

Is P019 an armored cable?

TBC — source required. The current P019 construction table does not explicitly list an armor layer, but absence from a draft is not proof that the layer is absent.

Does a 1.6 mm messenger define the approved aerial span?

No. Messenger diameter alone does not approve a span. Route loads, messenger construction, sag/tension, attachment points, safety factors and compatible hardware must be reviewed together.

Are connectors included?

No connector is identified in the current P019 record. Treat it as bulk cable unless an approved BOM states otherwise.

What bend limit applies during installation?

The draft states 20D “under load,” but the exact condition and the separate static/service limit require source confirmation. Do not convert this into an installation instruction until the controlled datasheet defines D and the test condition.

What attenuation values are stated?

The internal draft states ≤0.36 dB/km at 1310 nm and ≤0.25 dB/km at 1550 nm. These values require source confirmation and do not include connector, splice, splitter or design margin losses.

What temperature range applies?

The draft states −20°C to +70°C for operation and −10°C to +60°C for installation. Storage and transport limits are not provided and must not be inferred.

Which documents should be approved before ordering?

Approve the exact product datasheet, construction drawing, count-specific specification row, cable marking, packing specification and agreed inspection/test records.

What information is needed for an accurate quotation?

Provide the selected count, total length, reel/drum length, route and span data, load conditions, hardware interface, marking, destination and required documents. If any route input is missing, request an engineering review instead of assuming suitability.

Can competitor specifications be used to fill missing values?

No. Other suppliers’ dimensions, materials, ratings and test results do not validate a BWNFiber product.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.