Armored / Direct Burial Cable

GYXS/GYXTW 2-24F Unitube Light-Armored Fiber Optic Cable

GYXS/GYXTW 2-24F Unitube Light-Armored Fiber Optic Cable with documented armored construction at 2-24F. Match armor and jacket to the route before quoting.

Armored Direct Burial Cable Armored Fiber Optic Cable

GYXS/GYXTW

Product value summary

The BWNFiber GYXS/GYXTW 2–24F unitube light-armored fiber optic cable is a bulk outdoor cable configuration recorded with a gel-filled central loose tube, water-blocking material, longitudinal PSP, two parallel steel wires and a PE sheath. The supplied product record covers 2–12F and 14–24F count groups and lists single-mode and multimode fiber alternatives. Confirm the exact GYXS/GYXTW variant, dimensions, route qualification and mechanical row before approval.

Short answer for buyers

Choose the fiber count group, select one fiber grade, then verify the approved mechanical configuration for that variant. The supplied record does not establish connectorization, installation temperature, direct-burial approval, self-supporting aerial use, packing length, standards compliance or test-document availability. Include those requirements in the RFQ instead of assuming them from the family name.

Key features from the supplied record

  • Fiber-count groups: 2–12F and 14–24F.
  • Fiber alternatives listed: G.652, G.655, 50/125 μm and 62.5/125 μm.
  • Construction recorded: gel-filled central loose tube, water-blocking material, longitudinal PSP, two parallel steel wires and PE sheath.
  • Optical values are wavelength- and fiber-grade-specific; alternatives must not be combined into one assumed configuration.
  • Storage/operating temperature recorded in V4: -40°C to +70°C.

Technical specifications

Construction

ParameterSupplied valueEvidence/status
Product familyGYXS/GYXTWV4 product record; confirm exact variant
Fiber count2–12F or 14–24FV4 product record
TubeGel-filled central loose tubeV4 construction row
Water managementWater-blocking materialV4 construction row
ArmorLongitudinal PSPV4 construction row
Strength membersTwo parallel steel wiresV4 construction row
Outer sheathPEV4 product record
Cable diameter/toleranceTBC — source requiredNot supplied in V4

Mechanical values as supplied

The V4 record contains two rows for each count group. It does not identify which row belongs to which GYXS/GYXTW variant or suffix. Publish the values only after engineering maps the rows to an approved configuration.

Count groupReference weight (kg/km)Tensile, long/short (N)Crush, long/short (N/100 mm)Bend, dynamic/staticStatus
2–12F82600 / 1500300 / 100010D / 20DSupplied; variant mapping TBC
14–24F127600 / 1500300 / 100010D / 20DSupplied; variant mapping TBC
2–12F1241000 / 3000300 / 100010D / 20DSupplied; variant mapping TBC
14–24F1471000 / 3000300 / 100010D / 20DSupplied; variant mapping TBC

Optical characteristics

Select one fiber grade and confirm the current datasheet revision. The values below are alternatives from the supplied V4 table, not a combined specification for every cable.

Fiber typeAttenuation @1310 (dB/km)Attenuation @1550 (dB/km)Attenuation @850 (dB/km)Attenuation @1300 (dB/km)Bandwidth @850 (MHz·km)Bandwidth @1300 (MHz·km)Cable cutoff λcc (nm)Numerical aperture
G.652≤0.36≤0.22————≤1260—
G.655≤0.40≤0.23————≤1450—
50/125 μm——≤3.3≤1.2≥500≥500—0.200±0.015
62.5/125 μm——≤3.5≤1.2≥200≥500—0.275±0.015

Environmental and interface boundary

  • Storage/operating temperature: -40°C to +70°C, as labelled in the supplied V4 record.
  • Installation temperature: TBC — source required.
  • Installation route approval (duct, aerial, direct burial or other): TBC — source required. “Outdoor access and distribution” is the supplied application description and is not a route approval.
  • Interfaces/connectors: this is a bulk cable record; connectors and termination are not specified. Confirm if a terminated assembly is required.
  • Standards/compliance: TBC — source required. Do not infer compliance from the GYXS/GYXTW name.

How to select the configuration

  1. Define the route and network role: access, distribution, duct, aerial or another documented use.
  2. Select the fiber count group and reserve capacity for the splice/termination plan.
  3. Select one fiber grade: G.652, G.655, 50/125 μm or 62.5/125 μm, subject to project compatibility.
  4. Ask BWNFiber to map the exact GYXS/GYXTW variant to the approved diameter, weight, tensile and crush row.
  5. Confirm temperature, water management, armor, sheath, drum/roll plan, marking and required documents.
  6. Approve only against the current datasheet/drawing and project acceptance requirements.

Differences from related products

  • 2–12F central loose tube outdoor armored cable: use the existing BWNFiber page for that count-specific product intent; do not combine its values with this 2–24F record.
  • Other armored/direct-burial families: a steel-tape or PE construction does not by itself prove direct-burial approval. Compare the declared route, strength system, water management, dimensions and acceptance documents.
  • Connectorized fiber assemblies: this page is for bulk cable configuration, not a connector, polarity or end-face selection.

Use cases and limits

The supplied record describes outdoor fiber access and distribution. Duct, aerial, direct-burial, UV, rodent, fire and self-supporting claims require an approved source for the exact configuration. Use the broader fiber optic cable selection guide to define route and project constraints before selecting this model. For category context, review the armored and direct-burial cable range and the FTTH drop cable range only when the route and network role match.

Testing and quality-control documents

TBC — source required before publication. Request the approved datasheet, construction drawing, optical test conditions, mechanical-test method/results, inspection points and acceptance limits for the selected variant. Do not describe the cable as factory-tested, certified or compliant until the corresponding document is available.

Packaging and procurement information

Drum/roll length, reel dimensions, cable marking, MOQ, price, stock, lead time and warranty are TBC — source required. These fields should be confirmed for the quotation rather than inferred from another GYXTW page.

Required information for an RFQ

Send:

  • Product family and exact variant: GYXS/GYXTW, plus any approved suffix.
  • Fiber count: 2–12F or 14–24F.
  • Fiber grade: G.652, G.655, 50/125 μm or 62.5/125 μm.
  • Total length, required length per drum/roll and quantity.
  • PE sheath requirement, marking text and destination.
  • Route and installation method, required diameter/space, tensile/crush/bend limits and temperature conditions.
  • Required datasheet, drawing, test report, standard or acceptance documents.

Datasheet, drawing and test-report area

  • Product datasheet: TBC — source required
  • Construction drawing: TBC — source required
  • Optical/mechanical test report: TBC — source required
  • Packaging/drum specification: TBC — source required

RFQ CTA

Request a configuration review and quotation. Send the fiber count, fiber grade, route, total length, drum plan, marking, destination and any required mechanical or compliance documents. BWNFiber should confirm the exact variant and return the approved specification before order release.

FAQ

FAQ

Which fiber counts does this page cover?

The supplied record covers 2–12F and 14–24F groups. Confirm the exact count and variant before quotation; do not assume that every count shares the same diameter or mechanical row.

What is the recorded construction?

The record lists a gel-filled central loose tube, water-blocking material, longitudinal PSP, two parallel steel wires and a PE sheath.

Does this page include connectors?

No connector or termination is specified in the supplied record. Treat it as a bulk-cable configuration and request a separate terminated-assembly specification if needed.

Which optical option should I choose?

Choose one fiber grade based on the link and equipment requirements, then verify the wavelength-specific values in the approved datasheet. The table lists alternatives; they are not one combined cable specification.

Is it approved for duct, aerial or direct-burial installation?

The supplied record says outdoor fiber access and distribution but does not provide route-specific approval. Request engineering confirmation for the intended installation method.

What should I send for a quotation?

Send the exact variant, fiber count and grade, total length, drum/roll requirement, quantity, marking, destination, route/load requirements and required technical documents.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.