GYTZS
GYTZS 24-144F Loose Tube LSZH Outdoor Fiber Optic Cable
GYTZS 24-144F Loose Tube LSZH Outdoor Fiber Optic Cable for outdoor plant use at 24-144F. Confirm model, fiber count and installation method against the source drawing.

Product Value Summary
The BWNFiber GYTZS page is intended for buyers specifying a stranded loose-tube outdoor fiber cable with metallic tape armor. The working record covers 24–144 fibers and several optical-fiber options, but the jacket description is not yet release-ready: LSZH in the product name conflicts with PE/HDPE in the extracted specification table. Ask BWNFiber to confirm the approved construction drawing and jacket classification before using this model in a tender, BOM or installation plan.
Short Buyer Answer
Use this page when the required model is GYTZS and the project needs a count-specific cable configuration rather than a general outdoor-cable overview. Before quotation, confirm the fiber count, optical-fiber grade, exact jacket compound/classification, installation route, required mechanical limits, drum length and documentation package. Do not treat values from different rows or fiber grades as one combined configuration.
Key Features — Pending Engineering Approval
- Model: GYTZS
- Working fiber-count scope: 24–144F — TBC
- Cable construction: stranded loose tube — TBC
- Armor: corrugated steel tape — TBC
- Fiber options: G.652.D and specified multimode grades — TBC against current BOM
- Jacket: TBC — the supplied records conflict between LSZH and PE/HDPE
- Water-blocking system: TBC against approved drawing
- Central strength member: TBC; do not use for order release the current alternatives without configuration mapping
Technical Specifications — Source-Controlled Draft
| Parameter | Working value | Release status |
|---|---|---|
| Product model | GYTZS | Product owner approval required |
| Fiber count | 24–144F | TBC — approved count list required |
| Fiber type | G.652.D / 50/125 µm / 62.5/125 µm | TBC — map each grade to an orderable SKU |
| Loose-tube material | PBT | TBC |
| Fibers per tube | 12F/tube | TBC |
| Tube count | 1–12 | TBC — verify row alignment |
| Armor | Corrugated steel tape | TBC |
| Outer sheath | TBC — LSZH conflicts with PE/HDPE | Blocked |
| Central strength member | TBC | Blocked; current alternatives are not mapped |
| Cable diameter and weight | See approved count matrix | Blocked; do not use for order release extracted rows yet |
| Installation temperature | TBC | Approved test/datasheet required |
| Operating/storage/transport temperature | TBC | Separate each condition in final table |
| Bend radius | TBC | State installation and operation separately |
| Tensile and crush limits | TBC | State long/short-term value and test condition |
| Standard delivery length | TBC | Confirm packing specification |
Interfaces and Connector Options
This is a bulk fiber optic cable page; no connector or factory-termination interface is established in the supplied evidence. If a terminated assembly is required, treat it as a separate product/BOM and provide connector type, polish, end breakout, length tolerance, pulling protection and test requirements.
Fiber Type and Configuration Options
The working record lists G.652.D single-mode and 50/125 µm or 62.5/125 µm multimode alternatives. These entries must be confirmed as currently orderable GYTZS configurations. Select one fiber grade for the quoted cable; do not combine attenuation values or standards from different grades.
Compatibility and Application Conditions
Model name alone does not prove suitability for aerial, duct, direct-burial, indoor/outdoor transition, rodent-risk or fire-regulated routes. Provide the installation route, conduit/tray environment, pulling plan, minimum bend constraints, grounding/bonding requirement for metallic armor, applicable code/standard and required fire classification. BWNFiber Engineering should then confirm whether the proposed GYTZS construction is suitable or recommend another cable family.
How to Select the Correct Configuration
- State the installation route and environment.
- Select the required fiber count and one optical-fiber grade.
- Confirm the approved GYTZS layer construction and exact jacket material/classification.
- Match the final outside diameter and weight to ducts, clamps, entry glands, trays and handling equipment.
- Confirm installation and operating bend, tensile, crush and temperature limits.
- Define drum length, total quantity, sequential marking and delivery destination.
- Request the approved datasheet, construction drawing and applicable test/inspection documents before order release.
Differences from Related Products
| Product/page | Working distinction | Buyer use | Evidence status |
|---|---|---|---|
| GYTZS | Metallic tape-armored loose-tube model with jacket classification still to be confirmed | Exact GYTZS specification and RFQ | Jacket identity blocked |
| GYTS 16–144F | Live BWNFiber page identifies a GYTS G.652.D product; local draft lists PE black | Compare only after both approved datasheets are available | GYTS source also has open review items |
| GYFTZ 2–216F | Local draft describes an all-dielectric FRP/LSZH loose-tube cable | Where a non-metallic construction is required | Source review remains open |
| Armored / Direct Burial category | Broad category discovery | Compare available armored cable families | Category-level intent |
do not use for order release a definitive “GYTS vs GYTZS vs GYFTZ” performance claim until all three current datasheets and model-naming rules are approved.
Use Cases
Potential use cases must be selected from the approved datasheet. The current evidence is insufficient to promise duct, direct-burial, aerial, indoor/outdoor transition, rodent resistance or a specific fire-rated route. Add only the installation methods explicitly listed in the approved GYTZS product specification.
Testing and Quality-Control Process
TBC — BWNFiber must confirm which inspections, standards, sampling rules and deliverables apply to this product. Do not claim OTDR, attenuation, tensile, crush, water-penetration, flame, smoke, halogen, UV or environmental testing unless the method, acceptance limit, configuration and report availability are documented.
Recommended visible wording after confirmation:
Request the inspection and test-document package applicable to the quoted GYTZS configuration. The quotation should identify the fiber grade, cable construction, jacket classification, test references, acceptance limits and documents supplied with the order.
Packaging and Procurement Information
Standard drum length, allowable length tolerance, drum type, end sealing, marking, shipping protection, MOQ, lead time and warranty are TBC — source required. Do not inherit these terms from a sibling product or competitor page.
Required Information for an RFQ
Send:
- model reference: GYTZS;
- required fiber count;
- optical-fiber grade;
- installation route and environment;
- required jacket material and verified fire/halogen classification;
- applicable project standard or tender clause;
- required tensile, crush, bend and temperature limits;
- total cable length and length per drum;
- quantity, cable marking and sequential meter marking requirements;
- delivery destination and required date;
- required datasheet, drawing, inspection or test documents.
Datasheet / Drawing / Test-Report Download Area
- Approved GYTZS datasheet: TBC — source required
- Approved cable construction drawing: TBC — source required
- Jacket/flame/halogen evidence: TBC — source required
- Configuration-specific inspection/test document: TBC — confirm availability
Do not display a generic “Download Catalog” button as if it were the approved product datasheet.
RFQ / CTA
Request a configuration review for GYTZS
Send your fiber count, fiber grade, route, jacket/classification requirement, drum length, quantity and destination. BWNFiber should respond with the proposed configuration, approved datasheet/drawing, documented exceptions and a quotation.
Secondary action: Request the approved GYTZS datasheet — activate only after the correct document is uploaded and tested.
Image SEO and Source Plan
No new product image, test image, certification image or exact construction diagram was generated.
| Use | Current/recommended file | Alt text | Caption | Position | Source/QA |
|---|---|---|---|---|---|
| Existing construction graphic | Keep 800logo/GYTZS.webp until rights/source review | Labeled cross-section diagram of the proposed GYTZS loose-tube cable construction | Working GYTZS construction graphic; confirm layer labels against the approved drawing. | Product gallery or construction section | Existing 800×800 WebP; visible watermark; confirm rights, source and label accuracy |
| Approved product photograph | TBC — do not invent | Describe only the photographed cable and visible marking | State model/count only if visible and verified | Hero/gallery | Original BWNFiber source required |
| Approved construction drawing | TBC — do not recreate | Approved GYTZS cable construction drawing showing [verified layers] | Include drawing revision | Construction section | Engineering-issued drawing required |
| Test evidence | TBC — do not fabricate | Describe actual test setup/report page | Name method/configuration/date if approved | QA section | Authentic report with sensitive data reviewed |
The existing image labels “Out sheath,” “Corrugated steel tape,” “Water blocking system,” “Loose tube,” “Steel wire strength member,” “Fiber” and “Filling Compound.” It does not visually prove LSZH, PE/HDPE, flame performance or a specific count range.
Frequently Asked Questions
Is the GYTZS jacket LSZH or PE/HDPE?
The supplied working records conflict. The product name and batch workbook say LSZH, while the extracted specification table says PE/HDPE. BWNFiber must confirm the approved construction and any fire, smoke or halogen classification before this claim is published or quoted.
Which fiber counts are available?
The current working record covers 24–144F, but the approved orderable count list and count-specific construction table are still required.
Is GYTZS the same as GYTS?
No interchangeability should be assumed from similar model names. The final comparison must use the approved datasheet for each model, including jacket, armor, strength member, count range, dimensions, mechanical limits and applicable tests.
Can this cable be used for direct burial?
TBC. Metallic tape armor alone does not establish suitability for every direct-burial route. Confirm the approved installation method, water-blocking design, crush/tensile requirements, local code and project environment.
Is the cable rodent-resistant?
TBC. Corrugated steel tape may add mechanical protection, but a rodent-resistance claim requires the product design, test basis and intended risk level to be documented.
Which fiber grades can be ordered?
The working record lists G.652.D and multimode alternatives, but BWNFiber must confirm the current BOM and orderable grade/count combinations.
How should cable diameter be selected?
Use the approved diameter for the exact fiber count and construction. Check it against duct fill, entry glands, clamps, trays, pulling equipment and bend constraints; do not use a strength-member or tube diameter as the finished cable diameter.
What mechanical limits should be included in the installation plan?
Use the configuration-specific installation and operating bend radius, short- and long-term tensile load, crush limit and temperature ranges from the approved datasheet. The extracted V4 rows are not cleared for publication.
What documents should be requested before order release?
Request the approved datasheet, construction drawing, fiber/jacket specification, count-specific dimension table, applicable inspection/test plan and the documents BWNFiber will supply with the order.
What should be included in the quotation request?
Include the model, fiber count, fiber grade, installation route, jacket/classification requirement, mechanical constraints, total length, drum length, quantity, marking, delivery destination and required documents.
Related Products