GYTW
GYTW 4-60F Dual-Steel-Wire Loose Tube Outdoor Fiber Optic Cable
GYTW 4-60F Dual-Steel-Wire Loose Tube Outdoor Fiber Optic Cable for outdoor plant use at 4-60F. Confirm model, fiber count and installation method against the source drawing.

Product Value Summary
The BWNFiber GYTW page is intended for buyers specifying a multi-tube outdoor fiber optic cable with a central steel strength member, aluminum-tape layer and two parallel steel wires. The current BWNFiber source identifies a 4–60-fiber page scope and PE/HDPE sheath options, but its configuration tables also contain conflicting 4–72-fiber entries. Treat this page as a configuration and RFQ starting point—not as an approved cable schedule—until BWNFiber engineering confirms the count-to-diameter, weight and mechanical-value mapping.
Primary action: Request the controlled GYTW datasheet and configuration review.
Quick Answer: What Is This GYTW Cable?
This GYTW is presented in BWNFiber’s supplied product record as a stranded, multi-loose-tube outdoor cable. Its illustrated construction shows fibers in multiple PBT loose tubes around a central steel member, with tube-filling compound, a water-blocking system, an aluminum-tape layer, two parallel steel wires and an outer sheath. This construction must not be confused with a GYXTW central-unitube cable. Final installation suitability depends on the approved drawing, sheath, dimensions and mechanical limits for the exact fiber count.
Key Features Under Review
- Product family: GYTW multi-tube outdoor fiber optic cable
- Page scope: 4–60 fibers; the source also contains 4–72-fiber rows, so the orderable maximum is
TBC — BWNFiber engineering confirmation required - Fiber options listed in the source: G.652.D single-mode, 50/125 µm multimode and 62.5/125 µm multimode; exact commercial grade names are
TBC — source required - Loose-tube material: PBT
- Central strength member: steel wire; source-listed size 1.4 mm, pending drawing confirmation
- Additional strength members: two parallel steel wires; source-listed size 0.8 mm, pending drawing confirmation
- Tape layer: aluminum tape in the supplied drawing and extracted construction table; a source note also mentions PSP, so the final material designation is
TBC — resolve source conflict - Outer sheath: PE/HDPE options are listed; the exact compound and rating are
TBC — source required - Water blocking: water-blocking system and tube-filling compound are shown; the exact materials and test criteria are
TBC — source required
Technical Specifications and Evidence Status
| Parameter | Current BWNFiber record | Release status |
|---|---|---|
| Product model | GYTW | Confirmed in supplied page record |
| Cable structure | Stranded multi-loose-tube | Supported by supplied illustration; drawing revision required |
| Fiber-count scope | 4–60F in title/construction; 4–72F in configuration rows | TBC — conflict must be resolved |
| Fibers per tube | 6F or 12F per tube | TBC — map by exact count |
| Number of tubes | 1–6 in extracted table | TBC — verify row alignment and fillers |
| Fiber options | G.652.D; 50/125 µm MM; 62.5/125 µm MM | TBC — confirm exact grades and availability by count |
| Loose-tube material | PBT | Confirm against controlled drawing |
| Central member | Steel wire, source-listed 1.4 mm | TBC — confirm dimension/tolerance |
| Tape layer | Aluminum tape; conflicting PSP note | TBC — material conflict |
| Parallel steel wires | Steel wire, source-listed 0.8 mm | TBC — confirm count, diameter and placement |
| Outer sheath | PE/HDPE | TBC — confirm compound, color, thickness and ratings |
| Nominal cable diameter | 8.6 ± 0.5 mm for 4–30F; 9.6 ± 0.5 mm for 32–72F in extracted table | TBC — count range exceeds page scope |
| Nominal weight | 140 ± 5 kg/km and 145 ± 5 kg/km in extracted table | TBC — verify column mapping and build |
| Installation temperature | Source row shows −15 °C to +60 °C | TBC — confirm test/handling condition |
| Operation/transport temperature | Source row shows −40 °C to +70 °C | TBC — separate operation, storage and transport |
| Minimum bend radius | Source row shows 20D short term and 10D long term | TBC — define installation/static condition |
| Tensile load | Source row shows 1500 N short term and 600 N long term | TBC — confirm test method and exact build |
| Crush load | Source row shows 1000 N/100 mm short term and 300 N/100 mm long term | TBC — confirm test method and exact build |
| Standard drum length | 2 km | TBC — confirm availability for selected count and destination |
Optical Options
The supplied record includes single-mode and multimode attenuation rows, but it does not provide a controlled configuration code linking every optical grade to every fiber count and cable build. Do not combine the alternatives into one specification.
For an approval-ready quotation, request:
- the exact fiber manufacturer and grade;
- nominal operating wavelengths and the applicable attenuation limits;
- the cable-level test method and acceptance criteria;
- the test record format for the ordered drum;
- confirmation that the selected grade is available in the selected count and tube layout.
Compatibility and Installation Conditions
Do not approve this cable from the words “outdoor,” “armored” or “dual steel wire” alone. Confirm the route and interfaces first.
| Project condition | Information required before approval |
|---|---|
| Duct or conduit | Duct ID and occupancy, pulling method, maximum pulling tension, bend path, water condition, entry seal and grounding/bonding requirements for metallic elements |
| Supported or lashed aerial route | Messenger/support method, span, clamp interface, sag/tension limits, wind and ice conditions, clearances and local engineering approval |
| Direct burial | Explicit direct-burial declaration for the selected build, soil and rodent exposure, depth, protective method, armor/sheath construction and local project rules |
| Cable entry and closure | Approved overall diameter, minimum bend radius, gland/clamp range, metallic-member handling, splice tray capacity and fiber color code |
| Indoor transition | Transition point, pathway and the applicable fire/smoke requirement; PE or HDPE by itself does not establish an indoor fire classification |
How to Select the Correct GYTW Configuration
- Define the route. State whether each segment is ducted, lashed aerial, buried or an indoor transition.
- Select one fiber grade and count. Do not combine single-mode and multimode alternatives in one line item.
- Lock the construction. Confirm multi-tube GYTW, central steel member, tape material, parallel-wire details and sheath compound against one drawing revision.
- Match the physical interfaces. Check the approved cable diameter against ducts, glands, clamps, closures and bend paths.
- Approve the mechanical limits. Use the values and test methods for the exact quoted build—not a family-level example.
- Define acceptance evidence. Agree on the datasheet, drawing, drum test record, marking, packaging and deviation process before production.
GYTW vs. Related Outdoor Cable Families
| Family | Page role | Key distinction to confirm |
|---|---|---|
| GYTW | This product page | Multi-tube outdoor construction with central steel member and two parallel steel wires; tape material and exact count range require confirmation |
| GYXTW | Separate exact-model product pages | Central unitube construction, generally used for lower-count compact builds; do not treat it as the same model |
| GYTA | Separate product page/category route | Stranded loose-tube cable with aluminum/polyethylene laminate construction; strength-member layout differs by build |
| GYTS | Separate product page/category route | Stranded loose-tube steel-tape armored family; do not substitute its dimensions or loads for GYTW |
| ADSS | Aerial selection category and models | All-dielectric self-supporting design; a metallic GYTW construction is not an ADSS substitute |
Suitable Use Cases—Subject to Project Approval
- Outdoor access or distribution links where the approved GYTW build matches the duct or supported-route design.
- ISP, telecom or campus routes that need a multi-tube cable and documented metallic strength/armor construction.
- Projects that can approve the cable by exact drawing, count, sheath, dimensions and mechanical limits before release.
The current evidence does not establish universal suitability for direct burial, self-supporting aerial spans, fire-rated indoor pathways or every listed fiber grade.
Testing and Quality-Control Information to Request
BWNFiber should attach the following to the selected configuration before the page is cleared for publication or procurement use:
- controlled product datasheet and construction drawing;
- bill of materials or material declaration for the tape, sheath and strength members;
- configuration-specific dimensions and weight;
- applicable optical, tensile, crush, bend and temperature test methods and acceptance limits;
- drum-level optical test record format;
- cable marking, meter-mark and color-code specification;
- packaging/drum plan and permitted length tolerance;
- approved deviations and document revision identifiers.
No test result, certification or standard compliance is claimed in this offline draft.
Packaging and Procurement Information
The source lists a 2 km standard drum length. Confirm drum length, tolerance and packaging for the exact fiber count and destination before using that value in a purchase order.
Required Information for an RFQ
Send BWNFiber:
- product family: GYTW multi-tube outdoor cable;
- fiber grade and fiber count;
- installation route and support method;
- tape material and sheath requirements;
- required cable diameter or entry/clamp limits;
- tensile, crush, bend and temperature requirements;
- total length, length per drum and quantity;
- cable marking and fiber/tube color-code requirements;
- destination, delivery schedule and shipping-document requirements;
- required datasheet, drawing, test record, inspection or sample stage.
CTA: Request the controlled GYTW datasheet and a configuration-specific quotation.
Download Area
| Document | Status |
|---|---|
| Controlled GYTW datasheet | TBC — BWNFiber document owner required |
| Approved construction drawing | TBC — engineering revision required |
| Configuration-specific optical/mechanical table | TBC — row mapping required |
| Test-report template or agreed inspection plan | TBC — quality owner required |
Frequently Asked Questions
Is this GYTW cable the same as GYXTW?
No. The supplied GYTW illustration shows multiple loose tubes arranged around a central steel strength member. GYXTW is commonly presented as a central-unitube family. Confirm the exact BWNFiber model code and drawing rather than treating the names as interchangeable.
Does this page cover 4–60 fibers or 4–72 fibers?
The title and one construction field state 4–60F, while configuration rows state 4–72F. The publishable and orderable range is therefore TBC — BWNFiber engineering confirmation required.
Is the tape layer aluminum tape or PSP steel tape?
The supplied illustration and extracted construction field say aluminum tape, while an internal source note mentions PSP. This conflict must be resolved against the original drawing or bill of materials before publication.
Can this cable be installed in a duct, aerially or by direct burial?
The current BWNFiber record describes a general outdoor access/distribution role but does not provide an approved installation declaration for each method. Submit the route and request a configuration-specific suitability statement and mechanical limits.
Which optical fiber should I select?
Choose one project-specified fiber grade and wavelength plan. The page lists G.652.D and multimode alternatives, but availability and attenuation limits must be linked to the exact cable configuration and controlled datasheet.
What must be included in a GYTW quotation request?
Provide the fiber grade and count, route, support method, sheath/tape requirements, mechanical and environmental requirements, total length, drum plan, quantity, marking, destination and required approval documents.
Related Products