GYTS-nB1.3
GYTS-nB1.3 12F / 24F / 48F / 96F / 144F Single-Sheath Steel-Tape Armored Outdoor Fiber Optic Cable
GYTS-nB1.3 12F / 24F / 48F / 96F / 144F Single-Sheath Steel-Tape Armored Outdoor Fiber Optic Cable with documented armored construction at 12F / 24F / 48F / 96F / 144F. Match armor and jacket to the route before quoting.

What this GYTS-nB1.3 record covers
The supplied BWNFiber record covers a GYTS-nB1.3 single-sheath, steel-tape armored outdoor fiber optic cable in 12F, 24F, 48F, 96F and 144F configurations. The record lists duct/aerial installation, a black PE cover and PSP tape armor. Select one complete fiber-count row for quotation; do not combine dimensions, weights or mechanical values from different rows.
The supplied record is still marked NEEDS REVIEW / do not use for order release. Product-specific values below are reproduced for offline review and require confirmation against the controlled BWNFiber drawing or datasheet before purchase or installation. The visible record does not by itself confirm fiber grade, self-supporting aerial status, direct-burial approval, standards, certification or water-blocking method.
Configuration table from the supplied record
| Parameter | 12F | 24F | 48F | 96F | 144F |
|---|---|---|---|---|---|
| Fibers per tube | 6 | 6 | 12 | 12 | 12 |
| Loose tubes + fillers | 2 + 3 | 4 + 1 | 4 + 1 | 8 + 0 | 12 + 0 |
| Loose-tube size (mm) | 1.6 | 1.6 | 1.9 | 1.9 | 1.9 |
| Central strength/coating field (mm) | 1.2 | 1.2 | 1.4 | 1.8 / 3.3 | 2.0 / 5.7 |
| Outer cover | PE, black | PE, black | PE, black | PE, black | PE, black |
| Armor | PSP tape | PSP tape | PSP tape | PSP tape | PSP tape |
| Outer-thickness field (mm) | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 |
| Cable diameter (mm) | 8.5 | 8.5 | 9.5 | 11.4 | 14 |
| Cable weight (kg/km) | 62 | 60 | 77 | 110 | 162 |
| Tensile, long/short (N) | 1000 / 3000 | 1000 / 3000 | 1000 / 3000 | 1000 / 3000 | 1000 / 3000 |
| Minimum bend radius during installation | 20 × cable diameter | 20 × cable diameter | 20 × cable diameter | 20 × cable diameter | 20 × cable diameter |
| Minimum bend radius after installation | 10 × cable diameter | 10 × cable diameter | 10 × cable diameter | 10 × cable diameter | 10 × cable diameter |
Engineering review note: The source labels the central-strength/coating field ambiguously and does not expose the test definition for the tensile row. Confirm the table alignment, units and construction drawing before treating these as approved specifications.
Optical values in the supplied record
The supplied optical table lists: mode-field diameter at 1310 nm 9.2 ± 0.4 μm; cladding diameter 125 ± 1 μm; core concentricity error ≤0.6 μm; cladding non-circularity ≤1.0%; cable cut-off wavelength ≤1260 nm; fiber cut-off wavelength 1180–1330 nm; primary coating values of 245 ± 10 μm excluding the color layer and 250 ± 15 μm including it; coating-cladding concentricity error ≤12.5 μm; fiber curl radius ≥4 m; attenuation ≤0.36 dB/km at 1310 nm and ≤0.21 dB/km at 1550 nm; chromatic-dispersion rows within 1288–1339 nm and at 1550 nm; zero-dispersion wavelength 1300–1324 nm; zero-dispersion slope ≤0.092 ps/nm²·km; and dispersion-mode bias 0.5 ps/km¹ᐟ².
These are source-listed values, not a finished-cable acceptance report. BWNFiber must confirm the fiber grade, test method, sample identity and whether each row is fiber-level or finished-cable-level before publication.
Mechanical and environmental values
| Parameter | Source-listed value |
|---|---|
| Operation temperature | −30°C to +60°C |
| Installation temperature | −30°C to +60°C |
| Storage temperature | −40°C to +70°C |
| Macro-bending loss | ≤0.1 dB at Φ=60 mm, 100 turns, 1550 nm |
| Tensile, long/short | 1000 / 3000 N |
| Minimum bend radius during installation | 20 × cable diameter |
| Minimum bend radius after installation | 10 × cable diameter |
The source label Tensile Long/Short is preserved. Do not relabel it as MAT, RTS or crush resistance without the engineering definition and test method. A bend-radius value does not establish a route or installation approval by itself.
Application and compatibility boundary
The supplied record lists duct/aerial installation. It does not establish that this cable is self-supporting, ADSS, approved for a particular utility voltage, or approved for direct burial. Confirm the support method, route loads, water exposure, burial requirement, attachment hardware and local installation rules with BWNFiber engineering before ordering.
This page is for the exact GYTS-nB1.3 configuration. Broad armored-cable selection and direct-burial education belong on the approved category/guide page. A related GYTS, GYTA53 or GYXTW model is not interchangeable merely because it has a similar fiber count.
How to select one complete configuration
- Choose one fiber-count row: 12F, 24F, 48F, 96F or 144F.
- Carry that row’s tube/filler plan, diameter, weight, tensile label and bend-radius values together.
- Confirm the controlled drawing for fiber grade, central member, water-blocking system, sheath and armor details.
- State whether the route is duct, supported aerial, direct burial or another installation; do not assume the label approves the route.
- Request the approved datasheet, drawing, test/document schedule and drum plan before purchase-order release.
For broad direct-burial and armored-route education, see BWNFiber Direct Burial Fiber Optic Cable. For a different central-loose-tube construction, compare 2–24F Central Loose Tube Outdoor Armored Cable and 2–12F Central Loose Tube Outdoor Armored Cable only after checking construction and application boundaries. If the route is a subscriber drop rather than a backbone cable, review FTTH Drop Cable options instead; these pages do not establish interchangeability.
RFQ checklist
Send the selected fiber count, total cable length, length per drum or roll, quantity, cable marking, delivery destination, route type, support method, required fiber grade, environmental conditions and requested drawings/test records. Ask BWNFiber to identify the controlling document revision and confirm that all quoted values come from the selected row.
Primary CTA
Request a GYTS-nB1.3 configuration review — send the selected fiber count, route type, total/drum length, quantity, marking and destination. Ask BWNFiber to return the controlled datasheet, drawing and applicable test/document schedule before approving the quotation.
FAQ
Which fiber counts does this page cover? The supplied record covers 12F, 24F, 48F, 96F and 144F. Select one complete configuration row.
Is this cable self-supporting aerial cable? The visible record says “Duct/Aerial installation” but does not establish ADSS or a self-supporting messenger/load design. Confirm the support method with engineering.
What armor and sheath are listed? The record lists PSP tape armor and a black PE cover. Confirm the controlled construction drawing before purchase.
What tensile values are listed? The source lists 1000/3000 N as long/short tensile. Do not call these MAT or RTS without confirmation of the test definition.
What temperatures are listed? Operation and installation are listed as −30°C to +60°C; storage is listed as −40°C to +70°C. Confirm the approved environmental test basis.
Can I combine values from two count columns? No. Quote one complete fiber-count row.
What should a quotation include? Fiber count, total and drum lengths, quantity, marking, destination, route/support method, construction requirements, drawings, test evidence and commercial terms.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.